Hospital Street Light Energy Saver, Voltage Reduction, Voltage Stabilization and Dimming, Aix - 2c - 30, Aix - 2c - 50 Remote Time Control
Hospital Street Lamp Energy Saver, Voltage Step-down, Stabilization and Dimming AIX-2C-30, AIX-2C-50 Remote Time Control. Based on the fluctuation of the user's power grid voltage and the nature of the lighting load, it provides dynamic, real-time and intelligent voltage-stabilized power supply for lighting facilities. That is, users can set the power-saving voltage output according to their own needs, and program the running time and power supply voltage of the lighting load to minimize the power consumption and temperature of lighting fixtures.
Summary of specifications of AIX Street Lamp Energy Saver series: AIX-2C-10, AIX-2C-15, AIX-2C-20, AIX-2C-25, AIX-2C-30, AIX-2C-35, AIX-2C-40, AIX-2C-45, AIX-2C-50, AIX-2C-55, AIX-2C-60, AIX-2C-63, AIX-2C-80, AIX-2C-100, AIX-2C-120, AIX-2C-150, AIX-2C-160, AIX-2C-180, AIX-2C-200, AIX-2C-250, AIX-2C-300,
Technical indicators of street lamp energy saver
1. Operating voltage:
Input: 380V (+25%,-5%), 50Hz
Output: +25%/-5% rated voltage +11%/-19%
Power-saving voltage +10%/-25%
Power-saving voltage (High-pressure sodium lamp) 380V/220V (±2%), 50Hz
Operation: Temperature: -40℃~+80℃
Relative humidity: 0~95%
No condensation MTBF≥60000h
Noise (at 1 meter)
Functional indicators of street lamp energy saver:
The energy-saving controller uses advanced intelligent control technology, electromagnetic voltage regulation technology and data control technology to improve lighting. It can provide real-time voltage stabilization and rapid voltage regulation (t
The series of products have the advantages of high power, small size, simple installation and debugging, and easy transformation of old systems.
The energy saver features a front-opening door, front-panel operation, and wall-mounted installation. The overall appearance should be beautiful and generous. The maximum dimensions (height, width, thickness) can be determined according to the on-site situation.
Soft start/full-voltage start. Users can choose soft start or full-voltage start according to different types of lamps to ensure the normal start of lamps and extend their service life. The start time is adjustable.
Lighting energy-saving products can achieve the functions of intelligent lighting control, effective protection of electric light sources, and reduction of power consumption.
The street lamp energy saver for hospital street lamps, with voltage reduction, voltage stabilization and dimming functions, such as models AIX - 2C - 30 and AIX - 2C - 50, which are factory - set with remote time control, can keep the lamps at an optimal lighting power while ensuring their normal operation. This approach can not only avoid lighting glare caused by excessive pressure but also significantly save electricity costs, with an energy - saving rate of up to over 20%. For different working conditions, the energy - saving circuits come in different models, including single - phase and three - phase types, to meet the needs of lighting and mixed circuits. Moreover, the lighting energy - saving circuit can work continuously under some harsh power grids and complex conditions, eliminating people's concerns..
There are 4 points to note for product maintenance:
1. The voltage stabilizer should be placed in a well - ventilated, dry indoor environment without direct sunlight and corrosive gases;
2. The selected power of the voltage stabilizer should be greater than the total power of the electrical equipment;
3. The switch of the voltage stabilizer should not be used as the main switch of the equipment. First, turn on the switch of the voltage stabilizer. After the power is output, connect different electrical equipment in turn from the smallest to the largest in terms of power. When shutting down, turn off the equipment from the largest to the smallest in power, and finally turn off the switch of the voltage stabilizer.
Send Inquiry to This Supplier
You May Also Like
-
L5504rvf, L5506rvf, L5512rvfp Intelligent Energy-saving Lighting Controller Sensing and Control SystemUS$ 246.15 - 253.85MOQ: 1 Unit
-
Sa/s2.16.1, Sa/s4.16.1, Sa/s12.16.1 Community Reconstruction Centralized Lighting Control SystemUS$ 153.69 - 192.31MOQ: 1 Unit
-
Intelligent Lighting Switch Modules Asf.rl.4.16a, Asf.rl.10.16a, Scenic Area Lighting Dimming PanelsUS$ 146.15 - 147.69MOQ: 1 Unit
-
Tlyzk - M4/10a Intelligent Lighting Module, Tlyzk - M8/10a, Tlyzk - M12/10aUS$ 146.15 - 161.54MOQ: 1 Unit
-
Intelligent Lighting Induction Control System Tlyzk-l12/16, Tlyzk-l16/16, Tlyzk-l18/16US$ 130.77 - 161.54MOQ: 1 Unit
-
Ddrc420fr Ddrc820fr Central Monitoring Software for Intelligent Lighting Switch Drivers in Parking LotsUS$ 146.15 - 153.85MOQ: 1 Unit
-
Installation Size Sv/s30.320.5, Juchuan Electric Sv/s30.640.5 System Power Supply SelectionUS$ 769.23 - 846.15MOQ: 1 Unit
-
Tlyzk-m4/16a Building Intelligent Lighting Sensing and Control System, Tlyzk-m8/16a, Tlyzk-m12/16aUS$ 121.54 - 123.08MOQ: 1 Unit
-
Bcx-h416, Bcx-h816, Bcx-h1216 Intelligent Switch Driver Module for Park Lighting Power SavingUS$ 246.15 - 253.85MOQ: 1 Unit
-
At/s6.6.1 At/s8.10.1 Switch Control Module, Logic Photosensitive Sensor, Smart Application ScenariosUS$ 146.15 - 152.31MOQ: 1 Unit