Intelligent Street Light Energy Saver, Universal Voltage Stabilizing and Current Limiting Energy-saving Cabinet Aixn-2c-80, Aixn-2c-120
The device uses microelectronics technology to control electromagnetic voltage regulation, monitors voltage changes in real - time, and dynamically adjusts the input voltage and current of the street lamp lighting circuit, enabling the lighting fixtures to operate under the optimal working conditions, reducing the additional power consumption of the fixtures, and achieving the purposes of power saving and power supply optimization. It uses a time - control switch or an astronomical clock combined with the main switch to control the on - off time of street lamps, realizing the functions of switching on/off, control, and protection of street lamps. The intelligent street lamp energy saver, the general voltage - stabilizing and current - limiting energy - saving cabinet AIXN - 2C - 80 and AIXN - 2C - 120, can also be set for time control. During the day, when the outdoor sunlight is sufficient, only 1/2 or 1/3 of the lamps need to be turned on. In the evening, when the outdoor sunlight gradually decreases and the traffic volume is medium - high, all corridor lights should be turned on. At midnight, when the traffic volume is very low, the lighting can be reduced to 1/3 again. In this way, energy is saved to the greatest extent. For restrooms, there are blind spots in this kind of places. Under normal circumstances, the lights here are often left on all the time, which is a waste. In the intelligent design, infrared sensors are used for control. The lights turn on when people come and turn off with a time - delay when people leave, or a combination of time control is adopted. Usually, it is controlled by the sensor, and after there are no people at night, the circuit is disconnected through timing to save energy.
Product specifications: AIXN - 2C - 30, AIXN - 2C - 40, AIXN - 2C - 45, AIXN - 2C - 60, AIXN - 2C - 50, AIXN - 2C - 63, AIXN - 2C - 80, AIXN - 2C - 100, AIXN - 2C - 130, AIXN - 2C - 160, AIXN - 2C - 120, AIXN - 2C - 150, AIXN - 2C - 180, AIXN - 2C - 200, AIXN - 2C - 400, AIXN - 2C - 300
Product functional characteristics of the street lamp energy saver:
Long - life and maintenance - free. While saving electricity costs, it extends the working life of the line load and lighting fixtures by 70%, greatly reducing the operation cost and workload.
When used for road lighting control, due to the characteristics of less traffic and fewer pedestrians in the second half of the night, in addition to setting the first - level power - saving level, the night - light function (i.e., the second - level power - saving level) should be enabled in the second half of the night to achieve better power - saving effects.
No high - frequency harmonics, no pollution to the power grid;
Easy installation: The installation is very simple. The lighting control module is installed in series between the general lighting starter and the power wiring.
It filters current fluctuations and surges, reduces reactive power loss, and improves various operating indicators of the power grid and lighting equipment.
No pollution to the power grid;
Street light energy saver parameters
Intelligent lighting voltage stabilization and regulation device
1. Operating voltage: Input: 380V (+25%,-5%), 50Hz Output: +25%/-5% rated voltage +11%/-19% energy-saving voltage +10%/-25% energy-saving voltage (high-pressure sodium lamp) 380V/220V (±2%), 50Hz
2. Operation Temperature: -40℃~+80℃ Relative humidity: 0~95% without condensation MTBF≥60000h Noise (at 1 meter)
3. No harmonic distortion in output
4. Bypass Automatic bypass available
5. Display Full digital intelligent display, large-screen LCD Chinese display
6. Overload capacity: Continuous long-term overload of 30%;
7. Cooling: Forced air cooling;
9. With soft start function;
10. Contactless voltage regulation;
11. Automatic voltage stabilization function
Intelligent street light energy saver, common fault removal of general voltage stabilization and current limiting energy-saving cabinets AIXN-2C-80 and AIXN-2C-120
1. Common faults are usually caused by incorrect installation and operation. Therefore, users can first check whether all connection lines are correct by themselves. Check according to the following fault phenomena by themselves. If the problem cannot be solved, they must contact the supplier immediately.
2. The switch trips due to wiring errors: Check whether there is a short-circuit in the circuit or whether the actual load is greater than the rated current.
3. Unable to enter the energy-saving state: Check whether it is running in bypass mode; whether the input voltage is too low and in the low-voltage protection state; whether the load current is too low and in the low-current bypass state.
4. When the fault indicator lights up, you can cut off the power supply and reset it. If the problem cannot be solved, you must contact the supplier immediately.
5. If the buttons on the control panel are ineffective, resetting will restore normal operation; if the buttons still don't work, contact the supplier to arrange inspection and maintenance.
Send Inquiry to This Supplier
You May Also Like
-
Street Lamp Energy-saving Voltage Regulation Device, Remote Monitoring and Control Terminal System Shdy-bz-60, Shdy-bz-50US$ 152.31 - 153.69MOQ: 1 Piece
-
Voltage-stabilizing, Energy-saving, Regulation and Monitoring System Sl-3-80 Sl-3-150 National Road Street Light Energy Saver, Light Control With Longitude and LatitudeUS$ 1538.46 - 1596.92MOQ: 1 Piece
-
Intelligent Lighting Control Scheme for Sewage Treatment Plant Sjdz-0.38-100a/3, Sjdz-zm-0.38-60US$ 153.54 - 153.69MOQ: 1 Piece
-
Hospital Street Light Energy Saver, Voltage Reduction, Voltage Stabilization and Dimming, Aix - 2c - 30, Aix - 2c - 50 Remote Time ControlUS$ 146.15 - 153.69MOQ: 1 Unit
-
Jgl-30t, Jgl-40t, Jgl-50t Landscape Street Lamp Lighting Load Voltage Stabilizing and Energy Saving Cabinet With Remote Monitoring, Remote Control and Remote Metering (three-remote) and Wireless MonitoringUS$ 1153.85 - 1169.23MOQ: 1 Set
-
Thdlxd-zm-0.4-30kw Dynamic Voltage Stabilization and Compensation Device for Street Lights in Huizhou Logistics Park, Lighting Voltage ReductionUS$ 1307.69 - 1323.08MOQ: 1 Set
-
Wuxi Factory Workshop Lighting Retrofit Energy-saving Device Sjdz-0.38-50 Sjdz-0.38-100US$ 152.31 - 153.69MOQ: 1 Piece
-
Factory Lighting Street Lamp Step-down, Voltage Stabilization and Dimming Device Dsom-zm-40kva/50kva/60kvaUS$ 453.85 - 461.38MOQ: 1 Unit
-
Building Lighting Energy-saving Renovation Intelligent Control System for pl - px - 416, pl - px - 816, pl - px - 1216US$ 138.46 - 153.69MOQ: 1 Unit
-
L5504rvf, L5506rvf, L5512rvfp Intelligent Energy-saving Lighting Controller Sensing and Control SystemUS$ 246.15 - 253.85MOQ: 1 Unit