Home > Industrial Equipment & Components > Boiler & Furnace > Boiler > Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler

Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler

Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler photo-1
Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler photo-2
Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler photo-3
Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler photo-4
Advanced Hot Water Boiler for Food Processing With Low Emissions Boiler photo-5
US$ 1000 - 6000 MOQ: 1 Unit
Key Specifications
Get Latest Price
Fuel:
Gas-fired
Function:
Water Boiler, Steam Boilers, Hot Water Boiler, Oil Boiler, Hot Air Boiler
Usage:
Industrial, Home, Vehicle, Power Station
Payment & Shipping
Payment Methods:
Port of Shipment:
shanghai
Delivery Detail:
20 days
Fuel Gas-fired
Function Water Boiler, Steam Boilers, Hot Water Boiler, Oil Boiler, Hot Air Boiler
Usage Industrial, Home, Vehicle, Power Station
Structure Water Tube
Installation Packaged Boiler
Water Circulation Forced Circulation
Drum Placement Vertical Boiler
Manufacturing Level A
Burning Style Chamber Combustion Boiler
Media Hot Water
Pressure Low Pressure
Warranty 1 Year
Color Customizable
Dimension(L*W*H) Customizable
Weight (Kg) Customizable
Transport Package Nude Packing
Specification 233-2330KW
Trademark ZHONG RUI
Origin China

Fully Premixed Vacuum/Phase Change Hot Water Boiler

Introducing the state-of-the-art Vacuum Indirect Gas Oil Hot Water Boiler, a pinnacle of high-efficiency, eco-friendly, and intelligent heating solutions. This remarkable piece of equipment combines advanced vacuum indirect heating technology with a wealth of R&D expertise in thermal systems. It is meticulously engineered for environments with the highest requirements for environmental stewardship, operational safety, and precise hot water temperature regulation.
Our cutting-edge boiler incorporates a vacuum indirect heat exchange architecture complemented by top-tier gas oil combustion components. This design ensures swift heat transfer, outstanding thermal efficiency, and consistent hot water output. Its sleek and compact form conserves valuable floor space, suited perfectly for both industrial and commercial environments with area constraints. The boiler is delivered fully assembled, ensuring rapid on-site installation and commissioning. Beyond water and fuel connections, no additional construction or complex installation processes are required, thereby minimizing deployment time and cost.
Every boiler undergoes rigorous factory inspection and exhaustive performance testing to ensure utmost safety, reliability, and longevity. The system comprises a vacuum-tight boiler body, an efficient gas oil combustion system, an intelligent temperature regulation system, premium instrumentation and pumps, along with other components, all harmoniously integrated for optimal and stable operation.
This Vacuum Indirect Gas Oil Hot Water Boiler boasts clean-burning gas oil technology, ensuring low emissions, user-friendly operation, precise hot water control, and robust safety features. It is the perfect choice for diverse applications, including industrial processing, commercial heating, hotel hot water provision, and other sectors where dependable hot water supply is critical.
Main Technical Parameters
Boiler Model: Customizable, e.g., ZR-VIGO Series
Structure Type: Vacuum Indirect, Water Tube, Gas Oil Fired
Rated Capacity: 233-2330KW
Rated Pressure: Low Pressure (customizable as per requirements)
Applicable Fuel: Gas Oil (Heavy Oil/Light Oil optional)
Circulation Mode: Forced Circulation / Natural Circulation, customizable
Installation Mode: Vertical / Horizontal, customizable
Warranty: Customizable, e.g., 1 Year

Product Parameters


Technical Parameters of Full Premix Vacuum/Phase Change Unit












Heat Output/Heat Power ×104kcal/h 20 30 40 50 60 80 90 100 120 150 180 200
KW 233 350 470 583 700 930 1050 1170 1400 1750 2100 2330
MW 0.233 0.35 0.47 0.58 0.7 0.93 1.05 1.17 1.4 1.75 2.1 2.33
Designed Thermal Efficiency  % 97-106











Flue Gas Temperature  ºC ≤(Return Water Temperature + 10ºC)











 Power Supply  V/Hz 220-380/50











Total Power Consumption  KW 3 3 3 6 6 6 6 6 6 8 8 12
Natural Gas Minimum Consumption Nm³/h 22 34 45 56 67 89 100 111 133 166 200 222
Valve Diameter DN 40 40 40 50 50 50 50 50 50 50 50 50
Pressure (Dynamic) kPa 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5 2-5
Nitrogen Oxides (NOx) mg/Nm³ 30










Boiler Safety Valve N3 DN 40 40 40 40 40 40 40 40 40 50 50 50
Boiler Steam Discharge N4 DN 40 40 40 40 40 40 40 40 40 40 40 40
Boiler BlowdownN5 DN 32 32 32 32 32 32 32 32 32 32 32 32
Condenser Condensate Discharge N6 DN 25 25 25 25 25 25 25 25 25 25 25 25
Boiler Flue Gas N7 φmm 194 194 194 245 245 273 273 273 325 377 377 377
Boiler Net Weight t 1.5 1.7 1.9 2.3 2.3 3.1 3.1 3.1 3.8 4.8 4.8 4.8
Hot Water Tank Capacity t 0.38 0.42 0.48 0.56 0.56 0.7 0.7 0.7 0.9 1.45 1.45 1.45
Operating Weight t 1.9 2.1 2.4 2.9 2.9 3.8 3.8 3.8 4.7 6.3 6.3 6.3
Vacuum Hot Water Unit Type A Converter (△t=10ºC, Inlet/Outlet Temperature: 40ºC/50ºC, 50ºC/60ºC)











Heat Output   ×104kcal/h 20 30 40 50 60 80 90 100 120 150 180 200
Rated Circulation  m³/h 20 30 40 50 60 80 90 100 120 150 180 200
Water Supply Port N1 /Return N2 DN 50 65 80 100 100 125 125 125 150 150 200 200
Vacuum Hot Water Unit Type B Converter (△t=20ºC, Inlet/Outlet Temperature: 40ºC/60ºC, 60ºC/80ºC)











Heat Output  ×104kcal/h 20 30 40 50 60 80 90 100 120 150 180 200
Rated Circulation  m³/h 10 15 20 250 30 40 45 50 60 75 90 100
Water Supply Port N1 / Return N2  DN 40 50 50 65 65 80 80 80 100 125 125 125
Slightly Positive Pressure Phase
Change Electric Hot Water Unit
Type A Converter (△t=25ºC, Inlet/Outlet Temperature: 95ºC/70ºC)











Heat Output ×104kcal/h 20 30 40 50 60 80 90 100 120 150 180 200
Rated Circulation m³/h 10 15 20 25 24 32 36 40 48 60 72 80
Water Supply Port N1 / Return N2 DN 40 50 50 65 65 80 80 80 125 125 125 125
Slightly Positive Pressure Phase
Change Electric Hot Water Unit
Type B Converter (△t=25ºC, Inlet/Outlet Temperature: 95ºC/70ºC)











Heat Output ×104kcal/h 20 30 40 50 60 80 90 100 120 150 180 200
Rated Circulation  m³/h 4 7 9 11 13 18 20 22 27 33 40 44
Water Supply Port N1 /Return N2  DN 40 40 40 50 50 65 65 65 65 65 80 80



Product Tags: Boiler , Hot Water Boiler , Electric Boiler

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Product Certifications
HACCP, TL900, QS9000, SA8000, ISO9001, ISO9004, ISO17799, ISO9000, ISO14000, ISO10441, ISO16949, TS16969, ISO19011:2000, OHSAS18001, Others
Port of Shipment
shanghai, guangdong
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Yangzhou, Jiangsu, China

Recommended Categories