Key Specifications
Get Latest Price
Certification:
CE, ISO9001, CCC, ROHS, Other, TUV
Application:
Villa Family, Sauna and Swimming Pool, Beauty Salons, Other
Heat Source:
Air-source
Payment & Shipping
Payment Methods:
Port of Shipment:
Guangzhou/Shenzhen
Delivery Detail:
15 days
Certification CE, ISO9001, CCC, ROHS, Other, TUV
Application Villa Family, Sauna and Swimming Pool, Beauty Salons, Other
Heat Source Air-source
Energy Efficiency Grade One
Heat Temperature 50-70°C
Work Environment Common Heat Pump
Heating Type Multi-power Heat
Compressor GMCC/Mitsubishi/Panasonic
Refrigerant R32
Heat exchanger Titanium in PVC
Casing material ABS Plastic+ Galvanized Sheet
Transport Package Plywood case
Specification 14kw
Trademark Canova
Origin Guangzhou, China
Model  CNV-5YC CNV-7YC CNV-9YC CNV-11YC CNV-15YC CNV-18YC CNV-21YC CNV-25YC CNV-21YC CNV-25YC CNV-28YC
1. DC inverter technology.                          
2. Higher efficiency than normal on/off type.     
3. Wide range of compressor frequency.      
4. Plastic ABS cabinet with excellent weather resistance.                                                
5. Eco friendly refrigerant: R32.     
Power Supply 220-240V~/ 50Hz 380-415V/3N~/50Hz
Performance Condition: Ambient Temp.:  (DB/WB) 27°C/24.3°C; Water Inlet/Outlet Temp.: 26°C/28°C.
Heating Capacity Range (kW) 1.5~5.52 1.5~7.21 1.8~9.48 2.8~11.51 3.48~15.3 4.34~18.1 4.72~21.21 5.05~25.28 4.72~21.21 5.05~25.28 5.4~28.06
Consumed Power Range (kW) 0.09~0.82 0.09~1.09 0.11~1.44 0.17~1.74 0.22~2.35 0.27~2.81 0.29~3.26 0.31~3.89 0.29~3.26 0.31~3.89 0.33~4.32
COP Range 16.7~6.7 16.7~6.6 16.4~6.6 16.5~6.6 15.9~6.5 16.1~6.4 16.2~6.5 16.2~6.5 16.2~6.5 16.2~6.5 16.3~6.51
Boost Mode Heating Capacity (kW) 5.52 7.21 9.48 11.51 15.3 18.1 21.21 25.28 21.21 25.28 28.06
COP 6.7 6.6 6.6 6.6 6.5 6.4 6.5 6.5 6.5 6.5 6.51
Smart Mode Heating Capacity (kW) 4.5 5.8 7.8 9.1 11.55 14.01 17 20.4 17 20.4 22.61
COP 8.91 9.03 9.02 9.32 9.18 9 9.35 8.9 9.35 8.9 8.92
Silent Mode Heating Capacity (kW) 2.1 2.8 3.5 5.5 7.35 8.7 10.2 12.3 10.2 12.3 13.91
COP 14.1 14.2 14.2 13.8 13.6 13.2 13.1 13.6 13.1 13.6 13.5
Performance Condition: Ambient Temp.:  (DB/WB) 15°C/12°C; Water Inlet Temp.: 26°C.
Heating Capacity (kW) 1.11~3.91 1.3~5.42 1.51~7.89 2.2~8.21 2.96~11.14 3.44~13.35 3.51- 14.21 3.81- 17.08 3.51- 14.21 3.81- 17.08 4.04~18.49
Consumed Power (kW) 0.13~0.75 0.16~1.06 0.18~1.52 0.27~1.61 0.36~2.19 0.41~2.61 0.43~2.78 0.48~3.35 0.43~2.78 0.48~3.35 0.49~3.56
COP 8.4~5.2 8.1~5.1 8.3~5.2 8.1~5.1 8.3~5.1 8.3~5.1 8.1~5.1 8~5.1 8.1~5.1 8~5.1 8.2~5.2
Boost Mode Heating Capacity (kW) 3.91 5.42 7.89 8.21 11.14 13.35 14.21 17.08 14.21 17.08 18.49
COP 5.2 5.1 5.2 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.2
Smart Mode Heating Capacity (kW) 3.1 4.3 6.1 6.58 8.65 10.55 11.2 13.5 11.2 13.5 14.63
COP 6.21 6.23 6.22 6.19 6.2 6.16 6.2 6.21 6.2 6.21 6.18
Silent Mode Heating Capacity (kW) 2.2 2.4 2.5 4.37 5.55 6.72 7.5 8.3 7.5 8.3 9.31
COP 7.59 7.55 7.58 7.53 7.55 7.54 7.5 7.52 7.5 7.52 7.53
Performance Condition: Ambient Temp.:  (DB/WB) 35°C/-; Water Inlet/Outlet Temp.: 30°C/28°C.
Cooling Capacity (kW) 1.51~3.22 1.78~3.75 1.92~5.13 2.48~6.33 3.41~8 4.15~9.88 4.4 - 10.12 4.6 - 11.5 4.4 - 10.12 4.6 - 11.5 4.65~13.6
Consumed Power (kW) 0.19~0.67 0.22~0.78 0.24~1.06 0.31~1.3 0.43~1.65 0.53~2.03 0.57~2.08 0.59~2.38 0.57~2.08 0.59~2.38 0.59~2.8
EER 7.95~4.81 7.92~4.78 7.86~4.85 7.85~4.88 7.91~4.85 7.9~4.87 7.75~4.86 7.81~4.88 7.75~4.86 7.81~4.88 7.82~4.86
Boost Mode Heating Capacity (kW) 3.22 3.75 5.13 6.33 8 9.88 10.12 11.5 10.12 11.5 13.6
COP 4.81 4.78 4.85 4.88 4.85 4.87 4.86 4.88 4.86 4.88 4.86
Smart Mode Heating Capacity (kW) 2.3 2.92 3.5 4.89 6.45 7.77 8.9 9.8 8.9 9.8 10.55
COP 6.1 5.98 5.95 5.86 5.88 5.74 5.69 5.62 5.69 5.62 5.65
Silent Mode Heating Capacity (kW) 1.8 2.18 2.4 3.12 4.15 4.88 5.55 5.86 5.55 5.86 6.55
COP 7.28 7.31 7.28 7.16 7.15 7.12 7.11 7.12 7.11 7.12 7.15
Max. Power Input (kW) 1.31 1.61 1.75 2.3 3.2 3.9 4.1 4.5 4.1 4.5 5.4
Max. Current (A) 5.95 7.32 7.96 10.5 14.5 17.7 18.8 19.5 7.3 8.5 10.2
Advised Pool Volume (m³) 10~20 15~30 20~40 25~50 30~60 35~70 45~80 55~90 45~80 55~90 65~100
Running Ambient Temp. Range () -10~43
Heating Temperature Range () 15~40
Cooling Temperature Range () 8~28
Refrigerant R32
Compressor Type DC Inverter Rotary
Compressor Brand GMCC/Mitsubishi/Panasonic
Throttling device Electronic expansion valve
4-Way Valve Yes
Fan Quantity 1
Heat Exchanger Titanium in PVC
Casing Material ABS Plastic+ Galvanized Sheet
Water Pipe Connection (mm) 50
Sound Pressure 1m dB (A) 30~43 32~45 33~47 33~47 34~48 34~48 35~50 35~52 35~50 35~52 36~52
Water Flow Volume (m³/h) 2.4 3.1 4.1 4.9 6.6 7.7 9.1 10.8 9.1 10.8 12
Water Pressure Drop (kpa) 15.00  17.00  18.00  15.00  18.00  23.00  32.00  35.00  32.00  35.00  38.00 
Electric Shock Proof
Water Proof Level IPX4
Net weight(kg) 41 45 47 53 53 62 82 87 82 87 92
Unit Dimensions(L*W*H) (mm) 910×355×620 1000×400×660 1130×455×760


Features:

· Mitsubishi DC inverter compressor

· Titanium tube in PVC shell heat exchanger

· Compact structure

· Intelligent defrosting

· Stable running,economic&durable

· Easy installation&operation

· Cooling in summer&heating in winter


Product Tags: Domestic swimming pool heat pump , Swimming Pool Heat Pumps , Full DC Inverter pool heat pumps

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2003
Overseas Office
Yes
Factory Size
1,000-3,000 square meters

Recommended Categories

Explore top categories and find suppliers for your specific needs