Home > Instruments & Meters > Test Instrument > Test Machine > Dsc Touch Screen Differential Scanning Calorimeter

Dsc Touch Screen Differential Scanning Calorimeter

Dsc Touch Screen Differential Scanning Calorimeter photo-1
Dsc Touch Screen Differential Scanning Calorimeter photo-2
Dsc Touch Screen Differential Scanning Calorimeter photo-3
US$ 6000 - 8000 MOQ: 1 Set
Key Specifications
Get Latest Price
Brand Name:
Deruitest
Place of Origin:
China
Model Number:
DR-C320
Payment & Shipping
Payment Methods:
Port of Shipment:
shenzhen
Delivery Detail:
15 days
Brand Name Deruitest
Place of Origin China
Model Number DR-C320
Power Other, 220V
Usage Other
Main technical parameters of the instrument:
Temperature range
Room temperature~1250℃
Temperature resolution
0.01℃
Temperature fluctuation
±0.1℃
Heating rate
0.1~100℃/min
Cooling rate
1~20℃/min
Temperature control method
heating, constant temperature, cooling
Cooling time
15min (1000℃…100℃)
Measuring range of balance
1mg~2g
Resolution
0.01μg
DSC range
0~±500mW
DSC resolution
0.01mW
Constant temperature time
0~300min arbitrarily set
Display mod
Chinese character large-screen LCD display
Atmosphere
inert, oxidizing, reducing, static, dynamic
Atmosphere device
Built-in gas flow meter, including two-way gas switching and flow rate control
Software
Intelligent software can automatically record the TG curve for data processing and print experimental reports
Data interface
Standard USB interface, special software
(free software upgrades from time to time)
Power supply
AC220V 50Hz

First, the core advantages of touch screen DSC

1. Intuitive operation

Graphical touch screen interface, instead of traditional buttons/knobs, simplifies parameter settings (e.g., temperature rise rate, temperature range, gas flow rate).


Real-time display of heat flow curves, support multi-touch zoom, drag and drop analysis.

2. Efficient data management

Built-in test templates (e.g. ISO 11357, ASTM E967), one-key call to preset programs.


Direct report export (PDF/Excel), support USB or wireless data transfer.

3. Intelligent Interaction

Fault self-diagnostic prompts (e.g., furnace lid not closed, thermocouple abnormality) to reduce the risk of operational errors.


Multi-language interface (Chinese, English, etc.), adapting to the needs of globalized laboratories.


Selection Precautions

1. Touch screen type:

 

Capacitive screen: high sensitivity, suitable for clean lab environment (e.g. TA, NETZSCH).

 

Resistive screen: low cost, wear-resistant, suitable for industrial environments (commonly used in domestic equipment).

2. Software compatibility:

 

Ensure that the analysis software supports the required functions (such as kinetic fitting, peak separation).


Domestic equipment need to confirm whether English interface is provided (international cooperation needs).


3. Extended functions:


High temperature module (>700°C), humidity control, joint TGA, etc. on demand.


4. after-sales service:

 

Imported brands usually provide global warranty, but the response period is longer; local service of national brands is faster.


VI. Maintenance and Calibration

1. Daily maintenance:


Regularly clean the touch screen with a soft cloth to avoid scratches (prohibit the direct spraying of alcohol).


Calibrate temperature and sensitivity monthly (use standards: indium, zinc, sapphire).


2. Troubleshooting:


Touch screen malfunction: restart the device or update the driver (contact the manufacturer's technical support).


Baseline drift: check reference crucible match, or clean furnace chamber residue.


Product Tags: Dta Testing Machine , Differential Thermal Analyzer , Differential scanning calorimeter

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2021
Factory Size
1,000-3,000 square meters
Annual Export Value
US$1 Million - US$1.5 Million

Recommended Categories