Home > Japan Mitsubishi Total Sulfur/chlorine/nitrogen Analyzer Nsx-2100v

Japan Mitsubishi Total Sulfur/chlorine/nitrogen Analyzer Nsx-2100v

Japan Mitsubishi Total Sulfur/chlorine/nitrogen Analyzer Nsx-2100v photo-1
Japan Mitsubishi Total Sulfur/chlorine/nitrogen Analyzer Nsx-2100v photo-2
Key Specifications
Get Latest Price
Main Markets:
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location:
Suzhou, Jiangsu, China
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

Instrument Introduction:

It is used for the detection of the total sulfur/chlorine/nitrogen content in all liquid and gas samples. The classic coulometric method (MCD-210) is used for sulfur and chlorine detection, the chemiluminescence method (ND-210) is used for nitrogen detection, and the atomic fluorescence method (SD-210) can also be used for sulfur detection. According to different detector selections, the content of various elements in the sample can be measured simultaneously.

Technical Parameters:
Model: NSX-2100V

Methods: Atomic fluorescence - sulfur, chemiluminescence - nitrogen, coulometric method - sulfur, chlorine
Oxidative decomposition: Quartz tube combustion method
Furnace temperature: ******1100℃
Samples: Liquid, gas, liquefied gas

Coulometric measurement electrodes: Cl: Silver electrode, S: Platinum electrode, silver electrode
Titration control: Automatic current control.
Measurement range: Atomic fluorescence - sulfur: 0.02 - 10000ug/m,

Chemiluminescence - nitrogen: 0.01 - 5000ug/ml for water samples, 0.03 - 10000ug/ml for non - water samples

Coulometric chlorine: 0.01 - 50ug (0.05 - 5000ug/ml),

Coulometric sulfur: 0.02 - 50ug (0.1 - 5000ug/ml)

(Normal samples: Burn at 1100℃ or lower)

Sample size: Non - aqueous liquid: ******200ul (Aqueous liquid: ******100ul)

Gas: SD - 210: ******25ml/GI - 220, 10ml/GI - 210

Gas: ND - 210: ******25ml/GI - 220, 10ml/GI - 210

Gas: MCD - 210: ******100ml/GI - 220, 10ml/GI - 210

Gas/liquefied petroleum gas quantitative loop: 10ml/30ul quantitative loop (GI - 240, GI - 300

Repeatability: (Using the automatic control sampler ABC for standard samples)

Measurement time: Atomic fluorescence/chemiluminescence: About 3 minutes (Sulfur and nitrogen can be measured simultaneously)

Coulometric titration method: Less than 10 minutes
Data processing function: Use a personal computer.
Display function: Display on a personal computer.
Printing function: External printer.
Keyboard: Personal computer keyboard.
Interface: Personal computer input/output (RS232C): 1 channel; Provide a balance interface (RS232C): 1 channel.
Gas requirements: Argon (Purity: 99.98% or higher, 290 - 490 kPa).
Oxygen (Purity: 99.7% or higher, 290 - 490 kPa).


Main Features:
Superior data software and the classic coulometric method can measure the ppm-level content of sulfur and chlorine in liquids and gases, which is suitable for many petrochemical departments.
The method complies with ASTM D3120, 3246, 3961, 5808, JIS K2541


Product Tags: Total sulfur, chlorine and nitrogen analyzer NSX- , NSX-2100V , Sulfur, chlorine and nitrogen

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Suzhou, Jiangsu, China