Japan Mitsubishi Total Sulfur/chlorine/nitrogen Analyzer Nsx-2100v
Instrument Introduction:
It is used for the detection of the total sulfur/chlorine/nitrogen content in all liquid and gas samples. The classic coulometric method (MCD-210) is used for sulfur and chlorine detection, the chemiluminescence method (ND-210) is used for nitrogen detection, and the atomic fluorescence method (SD-210) can also be used for sulfur detection. According to different detector selections, the content of various elements in the sample can be measured simultaneously.
Technical Parameters:
Model: NSX-2100V
Methods: Atomic fluorescence - sulfur, chemiluminescence - nitrogen, coulometric method - sulfur, chlorine
Oxidative decomposition: Quartz tube combustion method
Furnace temperature: ******1100℃
Samples: Liquid, gas, liquefied gas
Coulometric measurement electrodes: Cl: Silver electrode, S: Platinum electrode, silver electrode
Titration control: Automatic current control.
Measurement range: Atomic fluorescence - sulfur: 0.02 - 10000ug/m,
Chemiluminescence - nitrogen: 0.01 - 5000ug/ml for water samples, 0.03 - 10000ug/ml for non - water samples
Coulometric chlorine: 0.01 - 50ug (0.05 - 5000ug/ml),
Coulometric sulfur: 0.02 - 50ug (0.1 - 5000ug/ml)
(Normal samples: Burn at 1100℃ or lower)
Sample size: Non - aqueous liquid: ******200ul (Aqueous liquid: ******100ul)
Gas: SD - 210: ******25ml/GI - 220, 10ml/GI - 210
Gas: ND - 210: ******25ml/GI - 220, 10ml/GI - 210
Gas: MCD - 210: ******100ml/GI - 220, 10ml/GI - 210
Gas/liquefied petroleum gas quantitative loop: 10ml/30ul quantitative loop (GI - 240, GI - 300
Repeatability: (Using the automatic control sampler ABC for standard samples)
Measurement time: Atomic fluorescence/chemiluminescence: About 3 minutes (Sulfur and nitrogen can be measured simultaneously)
Coulometric titration method: Less than 10 minutes
Data processing function: Use a personal computer.
Display function: Display on a personal computer.
Printing function: External printer.
Keyboard: Personal computer keyboard.
Interface: Personal computer input/output (RS232C): 1 channel; Provide a balance interface (RS232C): 1 channel.
Gas requirements: Argon (Purity: 99.98% or higher, 290 - 490 kPa).
Oxygen (Purity: 99.7% or higher, 290 - 490 kPa).
Main Features:
Superior data software and the classic coulometric method can measure the ppm-level content of sulfur and chlorine in liquids and gases, which is suitable for many petrochemical departments.
The method complies with ASTM D3120, 3246, 3961, 5808, JIS K2541
Send Inquiry to This Supplier
You May Also Like
-
Sigma 700 Fully Automatic Surface TensiometerNegotiableMOQ: 0
-
Anton Paar Automated Multipurpose Powder X-ray DiffractometerNegotiableMOQ: 0
-
German Zwick Tensile Testing MachineNegotiableMOQ: 0
-
Anton Paar High-temperature Friction and Wear Tester ThtNegotiableMOQ: 0
-
Mettler Toledo Excellence Series Fast Moisture Analyzer Hx204/hs153NegotiableMOQ: 0
-
Anton Paar Pensky-martens Closed Cup Flash Point Tester Pma 500NegotiableMOQ: 0
-
Ceast Mfi5 / Mfi7 Series Melt Flow Indexer (melt Flow Rate Tester)NegotiableMOQ: 0
-
Anton Paar Rotational Rheometer Mcr72/92NegotiableMOQ: 0
-
Anton Paar Quantachrome Ultrapyc Series Fully Automatic True Density AnalyzerNegotiableMOQ: 0
-
Anton Paar Microwave Synthesizer Monowave 400NegotiableMOQ: 0