Supply of Wollastonite Composition Analyzer, Mingrui mr - Rsq Model, Calcium Silicate Composition Analyzer
Nanjing Mingrui MR-RSQ type Wollastonite Composition Analyzer , the analysis accuracy of each element reaches or is better than the allowable error specified in the relevant national standard analysis methods. For the joint measurement of multiple samples: silicon, aluminum, iron, titanium, calcium, magnesium, potassium, sodium, boron, barium, lead, zinc, zirconium, lithium, manganese, chromium, nickel, cobalt, phosphorus, tin, vanadium, tungsten, molybdenum, etc. It is widely used in the quantitative analysis of non-metallic industries in fields such as cement plants, refractory material plants, ceramic raw material plants, electrical porcelain plants, glaze factories, glass factories, daily-use and architectural ceramic plants, mines, universities, scientific research institutions, and quality inspection departments. Phone: 18651882886 (WeChat).
It has six high-speed measurement channels, and the channels automatically suck and drain liquid, which can realize the rapid and synchronous measurement of six elements, greatly shortening the measurement time. It is specially optimized for the quantitative analysis of chemical components in non-metallic industries such as the ceramic industry, refractory materials, and a wide variety of inorganic non-metallic minerals, as well as non-ferrous metals such as tungsten, molybdenum, nickel, cobalt, and copper and the smelting industry. With a brand-new design, the manual zero adjustment is cancelled. The newly developed multi-functional analysis software automatically adjusts the zero point and corrects the linear deviation. The stability of the instrument is greatly improved compared with the previous generation products. The instrument is easier to operate. Beginners can quickly, accurately and efficiently perform quantitative analysis on the content of more than twenty elements, with higher measurement accuracy and better reliability.
Analysis process: Sample preparation ---> Weighing and melting the sample ---> Leaching and color development ---> Instrument measurement of data ---> Software analysis and processing of results ---> Computer storage, printing and output of results.
Wollastonite Composition Analyzer Detection speed and detection error:
1. Detection speed:
Usually, starting from weighing, the detection of eight conventional components (CaO, SiO2, Al2O3, Fe2O3, MgO, TiO2, K2O, Na2O) in 2 - 4 samples can be completed within 3 hours, and the analysis of other elements can be completed within 4 - 6 hours.
2. Measurement error:
The analysis accuracy of each element meets the allowable error specified in the relevant national standard analysis methods. For ceramic materials, refer to GB/T4734 (specific parameters see Appendix 23), and for refractory materials, refer to GB/T6900 (specific parameters see Appendix 24). For the allowable error of high-silicon, high-aluminum or other high-content components without national standards, refer to the error specified in the Al2O3 item of GB/T6900 or industry standards.
Wollastonite Composition Analyzer Main elemental components and ranges measured: 0.00001~99% Al2O3: 0.00001~99% Fe2O3: 0.00001~99% TiO2: 0.00001~99% K2O: 0.00001~15% Na2O: 0.00001~15% CaO: 0.00001~99% MgO: 0.00001~99% B2O3: 0.00001~30% ZrO2: 0.00001~99% PbO: 0.00001~20% ZnO: 0.00001~99% MnO: 0.00001~15% Cr2O3: 0.00001~15% BaO: 0.00001~10% NiO: 0.00001~15% CoO: 0.00001~10% P2O5: 0.00001~30% Li2O: 0.00001~15% SnO: 0.00001~99%
Note: If the content range of the measured element exceeds this regulation, the user can appropriately reduce the sample weighing amount or aliquot amount according to the measurement method to meet the measurement requirements. The user can also propose in advance for us to provide the corresponding chemical analysis process to meet the user's measurement needs.
Wollastonite composition analyzer Types of measurable substances:
1. Rapid quantitative determination of components in silicate minerals and materials.
2. Rapid quantitative determination of each component in raw materials, semi-finished products, and finished products used in the production of cement, ceramics, refractory materials, glass, limestone, etc.
3. Rapid quantitative determination of the main components of the following chemical raw materials: chromium salt products, V2O5 and vanadium salt products, NiO and nickel salt products, Co¬2O3 and cobalt salt products, MnO and manganese salt products, titanium dioxide, phosphates, zinc oxide, borax, boric acid, barium carbonate, water glass, sodium humate, zirconium oxide, zirconium silicate, potassium salt products, sodium salt products, molybdate products etc.
4. Determination of each component in various non-ferrous metal minerals such as molybdenum ore, nickel ore, cobalt ore, tungsten ore.
Wollastonite composition analyzer Working conditions:
1. Regulated power supply: 220V, 50Hz
2. Main unit power: 100w (excluding computer, etc.)
3. Installation area: 3500×800mm
4. Ambient temperature: 20±10℃
5. Relative humidity: ≤85%
Wollastonite composition analyzer Installation and commissioning
Professional technicians will be sent to the site for installation, commissioning, and training until you master it.
Send Inquiry to This Supplier
You May Also Like
-
Supply of Spectrometer for Pressure Vessel Steel Plates, Mingrui Model ty - 9000, Spectral Analyzer for Pressure Vessel ShellsUS$ 14615.38 - 16153.85MOQ: 1 Unit
-
Supply of Spectral Analyzer for Clock and Watch Parts Manufacturing, Mingrui Model Ty-9000, Spectral Analyzer for Special BrassUS$ 13538.46 - 16615.38MOQ: 1 Unit
-
Supply of Zinc-copper Alloy Nut Analyzer, Mingrui Mr-cs-2f Type, Nut Material Element AnalyzerUS$ 2892.31 - 3353.85MOQ: 1 Unit
-
Supply of Carbon-sulfur Analyzer for Low-carbon High-alloy Steel, Mingrui Mr-cs995 Type, High-frequency Infrared Carbon-sulfur AnalyzerUS$ 6123.08 - 6584.62MOQ: 1 Unit
-
Supply of Battery Carbon-sulfur Analyzer, Mingrui Mr-cs995 Type, High-frequency Infrared Carbon-sulfur AnalyzerUS$ 6123.08 - 6584.62MOQ: 1 Unit
-
Supply of Molybdenum Concentrate Elemental Analyzer, Mingrui mr - Rsq Type, Molybdenum Ore Elemental AnalyzerUS$ 5661.54 - 6123.08MOQ: 1 Unit
-
Supply of Oxygen, Nitrogen and Hydrogen Analyzer for Iron Pots, Mingrui Sqm-3a Type, Nitrogen Content Analyzer for Iron PotsUS$ 41230.77 - 45846.15MOQ: 1 Unit
-
Supply of Lead and Alloy Spectral Analyzers, Mingrui Model ty - 9000, Lead-based Alloy Spectral AnalyzerUS$ 14615.38 - 16615.38MOQ: 1 Unit
-
Supply Spectrometer for Die-casting Machine Materials, Mingrui Ty-9000 Full-spectrum Direct-reading Spectral AnalyzerUS$ 14615.38 - 16153.85MOQ: 1 Unit
-
Supply of Ferrous Metal Mineral Analyzer, Mingrui mr - Rsc Type, Metal Mineral AnalyzerUS$ 1815.38 - 2123.08MOQ: 1 Unit