SPECIFICATION
| nternal Dimension | 600*600*600mm | 800*800*800mm | 1000*1000*1000mm |
| Extemal Dimension | 1100*800*1500mm | 1300*1000*1700mm | 1500*1100*1700mm |
| Oscillating Tube | Radius 200mm | Radus 300mm | Radius 400mm |
| nternal Chamber Material | Stainless Steel 304 | ||
| Extemal Chamber Materia | Stainless Stee Paint Coating | ||
| Observation Window | Waterproof Toughened Glass | ||
| Oscillating Angle | 40°、90°、120、360 | ||
| Oscillating Speed | PX3:2*120*for 4sIPX4:2*360*lor 12s | ||
| Spray Nozzle | 0.4mm(IPX3,IPX4),0.8mm(IPX4K) | ||
| Distance Between Two Nozzles | 50mm | ||
| Turntable Diameter | 200mm | 300mm | 400mm |
| Turntable Rotation Speed | 1-5 r/min | ||
| Water Flow Of Each Nozzle | Injector:0.07L/min±5%(IPX3&IPX4),0.6L/min±5%(IPX4) | ||
| Test Duration | 1~999,999min,Adjustable | ||
| Water Cycling System | Built-in Chamber Bottom For Recycling | ||
| Power Source | Single-phase,AC220V,50Hz | ||
Vertical Drip Rain Tester (IPX1/IPX2)
1. Test Standards
-
IPX1 (vertical drip)
◦
Requirement: Vertical drip (1±0.5 mm/min) for 10 minutes with no water penetration on the sample surface.
◦
Scenario: simulate natural rainfall or condensation environment (e.g. indoor equipment moisture test).
-
IPX2 (water dripping at an angle of 15°)
◦
Requirement: Vertical water drip (3±0.5 mm/min) when the sample is tilted at 15° for 10 minutes with no water penetration.
◦
Scenario: simulate the anti-drip capability of a device in a slightly tilted state (e.g., in-vehicle electronics).
Equipment core design
1. Drip system
-
Drip tray design:
◦
Adopt porous metal disk or needle nozzle with uniformly distributed holes (e.g., 0.4mm) to ensure water drops fall vertically and freely.
◦
Drip area covers the maximum projected area of the sample to avoid edge leakage.
-
Flow control:
◦
Drip rate is regulated by a precision flow meter and valve (IPX1: 1 mm/min, IPX2: 3 mm/min).
◦
Water tank capacity to meet continuous testing requirements (e.g. 10L or more).
2. Sample stage and tilting mechanism
-
IPX1 mode: the sample stage remains horizontal and drips vertically.
-
IPX2 mode: Motorized or manual tilt stage (0°-15° adjustable) to simulate a tilted state.
3. Material and Structure
-
Box material: stainless steel or anti-corrosion coating to prevent long-term water corrosion.
-
Transparent observation window: tempered glass or acrylic, easy to monitor the test process in real time.
-
Drainage system: bottom deflector + water collection tank, rapid drainage and recycling.
4. Control system
-
Automatic operation: touch screen to set drip time, flow rate, tilt angle.
-
Alarm function: water shortage automatic shutdown, timeout reminder.
Rainwater Test Chamber (Extended Function)
For compatibility with higher waterproof rating (e.g. IPX3/IPX4), a multi-functional rainwater test box is available, integrating the following modules:
1.
Vertical drip unit (IPX1/IPX2).
2.
Oscillating pipe shower unit (IPX3/IPX4).
3.
High-pressure water spray unit (IPX5/IPX6).
Selection of key parameters
Parameter
Description
Test rating
Support IPX1, IPX2, or extended to IPX3-IPX6.
Drip area
Selected according to sample size (e.g. 300 x 300mm to 1000 x 1000mm).
Flow rate accuracy
IPX1: 1±0.5 mm/min, IPX2: 3±0.5 mm/min.
Tilt mechanism
Motorized adjustment (accuracy ±1°) is superior to manual adjustment.
Standard Conformity
Conforms to IEC 60529, GB 4208, ISO 20653, etc.
Fields of application
-
Consumer electronics: cell phones, headphones, smart watches moisture test.
-
Automotive parts: Drip-proof verification of instrument panel, car display.
-
Industrial equipment: sealing test for control cabinets, outdoor enclosures.
Example of operation process
1.
IPX1 test:
◦
The sample is placed horizontally and a vertical drip is initiated for 10 minutes.
◦
Check for internal water ingress after testing.
2.
IPX2 test:
◦
Tilt the sample stage to 15° to initiate dripping for 10 minutes.
◦
Disassemble the sample to assess sealing performance.
Maintenance and Calibration
1.
Routine maintenance:
◦
Clean the drip tray to prevent scale from clogging the aperture.
◦
Check lubrication of tilt mechanism.
2.
Calibration requirements:
◦
Calibrate drip flow rate monthly (use measuring cup to measure 1 minute of water).
◦
Periodically check tilt angle sensor accuracy.
Send Inquiry to This Supplier
You May Also Like
-
High Temperature Pressure Jet Waterproof Test ChamberUS$ 3000 - 5000MOQ: 1 Set
-
Ipx3 Test Equipment Rain Test Chamber For LampUS$ 3000 - 5000MOQ: 1 Set
-
Constant Temperature and Humidity Test ChamberUS$ 3999 - 9999MOQ: 1 Set
-
Walk In Environmental Test ChamberUS$ 22500 - 37800MOQ: 1 Set
-
Thermal Shock Test Chamber (two-box Type)US$ 12500 - 31250MOQ: 1 Set
-
Double-layer High and Low Temperature Explosion-proof Test ChamberUS$ 12500 - 25000MOQ: 1 Barrel
-
Walk-in Type Battery Explosion-proof High and Low Temperature Test ChamberUS$ 18750 - 31250MOQ: 1 Set
-
Three Layers High and Low Temperature Explosion-proof Test ChamberUS$ 18750 - 31250MOQ: 1 Set
-
High Temperature And Humidity Vibration Test BenchUS$ 25000 - 37500MOQ: 1 Set
-
Energy-saving Large Custom Size Environmental Walk in Climate Test ChamberUS$ 50000 - 68750MOQ: 1 Set