SPECIFICATION

nternal Dimension600*600*600mm800*800*800mm  1000*1000*1000mm
Extemal Dimension1100*800*1500mm1300*1000*1700mm  1500*1100*1700mm
Oscillating TubeRadius 200mmRadus   300mm  Radius 400mm
nternal Chamber MaterialStainless Steel 304
Extemal Chamber MateriaStainless Stee Paint Coating
Observation WindowWaterproof Toughened Glass
Oscillating Angle40°、90°、120、360
Oscillating SpeedPX3:2*120*for   4sIPX4:2*360*lor 12s
Spray Nozzle0.4mm(IPX3,IPX4),0.8mm(IPX4K)
Distance Between
Two Nozzles
50mm
Turntable Diameter200mm300mm400mm
Turntable Rotation
Speed
1-5 r/min
Water Flow Of
Each Nozzle
Injector:0.07L/min±5%(IPX3&IPX4),0.6L/min±5%(IPX4)
Test Duration1~999,999min,Adjustable
Water Cycling SystemBuilt-in Chamber Bottom For Recycling
Power SourceSingle-phase,AC220V,50Hz

Vertical Drip Rain Tester (IPX1/IPX2)

1. Test Standards

IPX1 (vertical drip)

◦ 

Requirement: Vertical drip (1±0.5 mm/min) for 10 minutes with no water penetration on the sample surface.

◦ 

Scenario: simulate natural rainfall or condensation environment (e.g. indoor equipment moisture test).

IPX2 (water dripping at an angle of 15°)

◦ 

Requirement: Vertical water drip (3±0.5 mm/min) when the sample is tilted at 15° for 10 minutes with no water penetration.

◦ 

Scenario: simulate the anti-drip capability of a device in a slightly tilted state (e.g., in-vehicle electronics).


Equipment core design

1. Drip system

Drip tray design:

◦ 

Adopt porous metal disk or needle nozzle with uniformly distributed holes (e.g., 0.4mm) to ensure water drops fall vertically and freely.

◦ 

Drip area covers the maximum projected area of the sample to avoid edge leakage.

Flow control:

◦ 

Drip rate is regulated by a precision flow meter and valve (IPX1: 1 mm/min, IPX2: 3 mm/min).

◦ 

Water tank capacity to meet continuous testing requirements (e.g. 10L or more).

2. Sample stage and tilting mechanism

IPX1 mode: the sample stage remains horizontal and drips vertically.

IPX2 mode: Motorized or manual tilt stage (0°-15° adjustable) to simulate a tilted state.

3. Material and Structure

Box material: stainless steel or anti-corrosion coating to prevent long-term water corrosion.

Transparent observation window: tempered glass or acrylic, easy to monitor the test process in real time.

Drainage system: bottom deflector + water collection tank, rapid drainage and recycling.

4. Control system

Automatic operation: touch screen to set drip time, flow rate, tilt angle.

Alarm function: water shortage automatic shutdown, timeout reminder.


Rainwater Test Chamber (Extended Function)

For compatibility with higher waterproof rating (e.g. IPX3/IPX4), a multi-functional rainwater test box is available, integrating the following modules:

1. 

Vertical drip unit (IPX1/IPX2).

2. 

Oscillating pipe shower unit (IPX3/IPX4).

3. 

High-pressure water spray unit (IPX5/IPX6).


Selection of key parameters

Parameter

Description

Test rating

Support IPX1, IPX2, or extended to IPX3-IPX6.

Drip area

Selected according to sample size (e.g. 300 x 300mm to 1000 x 1000mm).

Flow rate accuracy

IPX1: 1±0.5 mm/min, IPX2: 3±0.5 mm/min.

Tilt mechanism

Motorized adjustment (accuracy ±1°) is superior to manual adjustment.

Standard Conformity

Conforms to IEC 60529, GB 4208, ISO 20653, etc.


Fields of application

Consumer electronics: cell phones, headphones, smart watches moisture test.

Automotive parts: Drip-proof verification of instrument panel, car display.

Industrial equipment: sealing test for control cabinets, outdoor enclosures.


Example of operation process

1. 

IPX1 test:

◦ 

The sample is placed horizontally and a vertical drip is initiated for 10 minutes.

◦ 

Check for internal water ingress after testing.

2. 

IPX2 test:

◦ 

Tilt the sample stage to 15° to initiate dripping for 10 minutes.

◦ 

Disassemble the sample to assess sealing performance.


Maintenance and Calibration

1. 

Routine maintenance:

◦ 

Clean the drip tray to prevent scale from clogging the aperture.

◦ 

Check lubrication of tilt mechanism.

2. 

Calibration requirements:

◦ 

Calibrate drip flow rate monthly (use measuring cup to measure 1 minute of water).

◦ 

Periodically check tilt angle sensor accuracy.


Product Tags: Vertical Drip Rain Tester , Water Spray Resistance Tester , Rain test chamber for evaluating the improvement of product waterproof level

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2021
Factory Size
1,000-3,000 square meters
Annual Export Value
US$1 Million - US$1.5 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs