ISO19642 HV Cable
Product description for high voltage cables for road vehicles:
(Reference Standard: IS0 19642-2019-5、IS0 19642-2019-9)
E-MARK Approval No: E24*118R03/01*0375*00
| Construction | Features |
| 1、Conductor1 | 1、Rated temperature :-40℃~+(125℃, 150℃) |
| Material: Bare Copper | 2、Rated Voltage:AC 600V/DC 900V;AC 1000V/DC 1500V |
| 2、Insulation | 3、Short-term Aging:240h,Comply with IS0 19642 |
| Material: XLPE | 4、Long-term Aging: 3000h,Comply with IS0 19642 |
| Color:Orange | 5、Flame Test: Comply With IS0 19642 |
| 3、Shielded | 6、Bending Radius: 4*OD@OD﹤15mm ; 6*OD@OD≧15mm |
| Material:Tinned Copper | 7、Dielectric Voltage:10kVac/5min. No Breakdown |
| 4、Sheath | 8、Oil Resistance:Comply With IS0 19642 |
| Material: XLPE | 9、Anti-tear Performance :>20N/mm |
| Color:Orange | 10、Environmental Requirements:Compliant with RoHS 2.0 and REACH |
1.AC 1000V/DC 1500V (shielded High-voltage cable):
AC 1000V/DC 1500V (shielded High-voltage cable):
| Product Series | Size | Conductor Stranded OD mm ( Ref.) | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity A (Ref.) | Over diameter mm (Ref.) | |
|
EVRP-125 (Rated temperature :-40℃~+125℃)
(Rated temperature :-40℃~+150℃) |
2.5mm2 | 2.00 | 7.60 | 30 | 6.30 | |
| 4mm2 | 2.60 | 4.71 | 40 | 7.30 | ||
| 6mm2 | 3.40 | 3.14 | 52 | 8.10 | ||
| 10mm2 | 4.40 | 1.82 | 75 | 9.80 | ||
| 16mm2 | 5.50 | 1.16 | 100 | 11.00 | ||
| 25mm2 | 7.00 | 0.743 | 125 | 13.40 | ||
| 35mm2 | 8.30 | 0.527 | 165 | 14.80 | ||
| 50mm2 | 10.00 | 0.368 | 215 | 17.00 | ||
| 70mm2 | 11.80 | 0.259 | 260 | 19.00 | ||
| 95mm2 | 13.80 | 0.196 | 320 | 21.60 | ||
| 120mm2 | 15.50 | 0.153 | 370 | 23.30 | ||
2. AC1000V/DC 1500V (unshielded High-voltage cable):
AC1000V/DC 1500V (unshielded High-voltage cable):
| Product Series | Size | Conductor Stranded OD mm ( Ref.) | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity A (Ref.) | Over diameter mm (Ref.) | |
|
EVR-125 (Rated temperature :-40℃~+125℃)
(Rated temperature :-40℃~+150℃) |
2.5mm2 | 2.00 | 7.60 | 30 | 3.50 | |
| 4mm2 | 2.60 | 4.71 | 40 | 4.30 | ||
| 6mm2 | 3.40 | 3.14 | 52 | 5.10 | ||
| 10mm2 | 4.40 | 1.82 | 75 | 6.50 | ||
| 16mm2 | 5.50 | 1.16 | 100 | 7.60 | ||
| 25mm2 | 7.00 | 0.743 | 125 | 9.70 | ||
| 35mm2 | 8.30 | 0.527 | 165 | 11.00 | ||
| 50mm2 | 10.00 | 0.368 | 215 | 13.10 | ||
| 70mm2 | 11.80 | 0.259 | 260 | 15.00 | ||
| 95mm2 | 13.80 | 0.196 | 320 | 17.10 | ||
| 120mm2 | 15.50 | 0.153 | 370 | 18.80 |
||
3、 AC 600V/DC 900V (unshielded High-voltage cable):
AC 600V/DC 900V (unshielded High-voltage cable):
| Product Series | Size | Conductor Stranded OD mm ( Ref.) | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity A (Ref.) | Over diameter mm (Ref.) | |
|
EVR-125 (Rated temperature :-40℃~+125℃)
(Rated temperature :-40℃~+150℃) |
2.5mm2 | 2.00 | 7.60 | 30 | 2.80 | |
| 4mm2 | 2.60 | 4.71 | 40 | 3.50 | ||
| 6mm2 | 3.40 | 3.14 | 52 | 4.30 | ||
| 10mm2 | 4.40 | 1.82 | 75 | 5.70 | ||
| 16mm2 | 5.50 | 1.16 | 100 | 6.90 | ||
| 25mm2 | 7.00 | 0.743 | 125 | 8.40 | ||
| 35mm2 | 8.30 | 0.527 | 165 | 10.00 | ||
| 50mm2 | 10.00 | 0.368 | 215 | 12.00 | ||
| 70mm2 | 11.80 | 0.259 | 260 | 14.00 | ||
| 95mm2 | 13.80 | 0.196 | 320 | 16.50 | ||
4、AC 600V/DC 900V (shielded High-voltage cable):
AC 600V/DC 900V (shielded High-voltage cable):
| Product Series | Size | Conductor Stranded OD mm ( Ref.) | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity A (Ref.) | Over diameter mm (Ref.) | |
|
EVRP-125 (Rated temperature :-40℃~+125℃)
(Rated temperature :-40℃~+150℃) |
2.5mm2 | 2.00 | 7.60 | 30 | 4.50 | |
| 4mm2 | 2.60 | 4.71 | 40 | 5.20 | ||
| 6mm2 | 3.40 | 3.14 | 52 | 6.40 | ||
| 10mm2 | 4.40 | 1.82 | 75 | 7.90 | ||
| 16mm2 | 5.50 | 1.16 | 100 | 9.40 | ||
| 25mm2 | 7.00 | 0.743 | 125 | 11.00 | ||
| 35mm2 | 8.30 | 0.527 | 165 | 12.90 | ||
| 50mm2 | 10.00 | 0.368 | 215 | 15.00 | ||
| 70mm2 | 11.80 | 0.259 | 260 | 17.00 | ||
| 95mm2 | 13.80 | 0.196 | 320 | 19.60 |
||
5、AC600V/DC 900V (multi-core shielded High-voltage cable):
AC600V/DC 900V (multi-core shielded High-voltage cable):
| Product Series | Cores | Size | Conductor Stranded OD mm ( Ref.) | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity A (Ref.) | Over diameter mm (Ref.) | |
|
QBJP2-C (Rated temperature :-40℃~+125℃)
(Rated temperature :-40℃~+150℃) |
2 | 1.5mm2 | 1.60 | 12.70 | 13 | 7.60 | |
| 3 | 11 | 8.00 | |||||
| 4 | 10 | 8.60 | |||||
| 5 | 9 | 9.20 | |||||
| 2 | 2.5 mm2 | 2.06 | 7.60 | 18 | 8.60 | ||
| 3 | 16 | 9.20 | |||||
| 4 | 14 | 9.90 | |||||
| 5 | 13 | 10.80 | |||||
| 2 | 4 mm2 | 2.70 | 4.71 | 26 | 10.10 | ||
| 3 | 22 | 10.60 | |||||
| 4 | 20 | 12.00 | |||||
| 5 | 18 | 13.20 | |||||
| 2 | 6 mm2 | 3.40 | 3.14 | 33 | 11.80 | ||
| 3 | 29 | 12.60 | |||||
| 4 | 26 | 13.60 | |||||
| 5 | 23 | 14.80 |
|||||
Send Inquiry to This Supplier
You May Also Like
-
QC/T1073 Multi-core Shielded High-voltage CableNegotiableMOQ: 50 Meters
-
AC1500V HV Flexible CableNegotiableMOQ: 50 Meters
-
NACS Charging CableNegotiableMOQ: 50 Meters
-
EN 50620、IEC62893 AC Charging CableNegotiableMOQ: 50 Meters
-
Oil-cooled EV Charging CableNegotiableMOQ: 50 Meters
-
UL EV Charging Cable(Suitable for NACS、CCS1)NegotiableMOQ: 50 Meters
-
TUV Certified AC Spring Charging CableNegotiableMOQ: 50 Meters
-
Water-cooled CableNegotiableMOQ: 50 Meters
-
PSE Charging CableUS$ 4 - 10MOQ: 500 Meters
-