UL EV Charging Cable(Suitable for NACS、CCS1)
UL EV charging cable (Suitable for NACS、CCS1)
Reference Standard:UL 2263
UL No.:E345899
Construction |
Features |
1.Conductor |
Rated temperature:-50℃~105℃ |
Material: Bare Copper |
Rated Voltage:1000V |
2.Insulation |
Conductor Resistance(at 20°C):8AWG≤2.23Ω/km;10AWG≤3.51Ω/km;16AWG≤14.1Ω/km;Test method Comply with UL 2556 |
Material: TPE |
15°C Insulation Resistance:8AWG≥34Ω.m;10AWG≥34Ω.m;16AWG≥45Ω.m;Test method Comply with UL 2556 |
Color:Black,red,Green/Yellow or other |
Dielectric Voltage: 4.0kV AC/1min(8AWG),3.0KV AC/1min(10AWG), 2.0KV AC/1min(16AWG). No Breakdown. Test method Comply with UL 2556 |
3.Filler |
Bending Radius Min:≥6OD. |
Material: PP hemp or cotton yarn |
Hot Shock:150℃/1h No cracks Test method Comply with UL 2556 |
4.Tape |
Flame Test:FT1.Test method Comply with UL 2556 |
Material:Non-woven fabrics |
Insulation tensile strength:Before Aging 5.5Mpa;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
5.Sheath |
Insulation Elongation:Before Aging200%;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
Material: TPE |
Jacket tensile strength:Before Aging 8.3Mpa;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
Color: Black or Orange |
Jacket Elongation:Before Aging200%;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556 |
Cold Bending Test:-40°C/4H,NO Cracking.Test method Comply with UL 2556 |
|
Hot Shock Test:150°C/1H,NO Cracking.Test method Comply with UL 2556 |
Type |
Main Lines Size |
Signal Lines Size |
Permissible ampacity@20°C ambient Ref. |
Over diameter Ref. mm |
OMG EVC 1001 |
3×10AGW |
22AGW(20AGW/18AGW/16AGW)0-6 |
32A |
12.1±0.5 |
OMG EVC 1002 |
2×9AGW+10AGW |
40A |
13.8±0.5 |
|
OMG EVC 1003 |
2×8AGW+10AGW |
48A |
15.1±0.5 |
|
OMG EVC 1004 |
2×6AGW+8AGW |
80A |
19.1±0.5 |
|
OMG EVC 1005 |
4×3AGW |
18AGW(20AGW/22AGW)0-8 |
170A(200A) |
28.5±1.0 |
OMG EVC 1006 |
4×2AGW |
200A(250A) |
31.0±1.0 |
|
OMG EVC 1007 |
1×1/0AGW |
300A-350A |
36.5±1.0 |
|
OMG EVC 1008 |
2×4AGW |
100A(125A) |
21.0±1.0 |
UL 2263 EV charging cable (Suitable for CCS1)
Reference Standard:UL 2263
UL No.:E345899
| Construction | Features |
| 1.Conductor | Rated temperature:-40℃~105℃ |
| Material: Bare Copper | Rated Voltage:300V;600V or 1000V |
| 2.Insulation | Flame Test: VW-1 Test method Comply with UL 2556 |
| Material: TPE | Min: Bending Radius: ≥6*OD |
| colour:Black,Red,Green/Yellow or other | Dielectric Voltage: 1.5kVac/1min. No Breakdown Test method Comply with UL 2556 |
| 3.Filler | Cold Bending:-40℃/4h No cracks Test method Comply with UL 2556 |
| Material: PP hemp or cotton yarn | Hot Shock:150℃/1h No cracks Test method Comply with UL 2556 |
| 4.Tape | Oil Resistance:IRM902, 60℃/168h Tensile and Elongation ≥70% Unaged value |
| Material:Non-woven fabrics | Crush Resistance:S≤12AWG 4.45kN, 12AWG<S≤2AWG, 11.1kN, 2AWG<S 15.6kN |
| 5.Sheath | Weather Resistance:720hin a xenon arc weatherometer, No cracks |
| Material: TPE | Environmental Requirements:Compliant with RoHS and REACH |
| Color: Black or Orange(customizable) |
| Type | Size | Conductor Stranded OD mm Ref. | Max. Conductor resistance mΩ/m@20℃ | Permissible ampacity@20℃ ambient Ref. | Over diameter Ref. mm | Packing M/Reel (Ref.) |
| 600V or 1000V EVE(TPE) | 3×16AWG | 1.5/1.2 | 14.1 | 12A | 10.8±0.5 | 1000m/700# |
| 3×14AWG | 1.9/1.2 | 8.88 | 16A | 11.8±0.5 | 800m/700# | |
| 3×12AWG | 2.4/1.2 | 5.58 | 23A | 14.3±0.5 | 500m/700# | |
| 3×10AWG | 3.0/1.2 | 3.51 | 32A | 15.6±0.5 | 500m/700# | |
| 2×8AWG+10AWG | 4.3/3.0 | 2.23/3.51 | 46A | 20.9±0.8 | 500m/950# | |
| 2×6AWG+8AWG | 5.4/4.3 | 1.40/2.23 | 63A | 23.4±0.8 | 400m/950# | |
| 3×16AWG+1×18AWG | 1.5/1.2 | 14.1/22.4 | 12A | 11.4±0.5 | 800m/700# | |
| 3×14AWG+1×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 13.5±0.5 | 500m/700# | |
| 3×12AWG+1×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 14.5±0.5 | 500m/700# | |
| 3×10AWG+1×18AWG | 3.0/1.2 | 3.51/22.4 | 32A | 15.8±0.6 | 500m/700# | |
| 2×8AWG+10AWG+18AWG | 4.3/3.0 | 2.23/3.51/22.4 | 46A | 20.9±0.8 | 500m/950# | |
| 2×6AWG+8AWG+18AWG | 5.4/4.3 | 1.40/2.23/22.4 | 63A | 23.4±0.8 | 400m/950# | |
| 2×4AWG+6AWG+18AWG | 6.6/5.4 | 0.882/1.4/22.4 | 75A | 27.0±0.9 | 300m/950# | |
| 3×16AWG+2×18AWG | 1.5/1.2 | 3.51/22.4 | 12A | 12.2±0.5 | 500m/700# | |
| 3×14AWG+2×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 14.1±0.5 | 500m/700# | |
| 3×12AWG+2×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 15.1±0.6 | 500m/700# | |
| 3×10AWG+2×18AWG | 3.0/1.2 | 3.51/22.4 | 32A | 15.8±0.6 | 500m/700# | |
| 2×8AWG+10AWG+2×18AWG | 4.3/3.0 | 2.23/3.51 | 46A | 20.9±0.8 | 500m/950# | |
| 2×6AWG+8AWG+2×18AWG | 5.4/4.3 | 1.40/2.23 | 63A | 23.4±0.8 | 400m/950# | |
| 2×4AWG+6AWG+2×18AWG | 6.6/5.4 | 0.882/1.4 | 75A | 27.0±0.9 | 300m/950# | |
| 2×2AWG+4AWG+2×18AWG | 8.2/6.6 | 0.555/0.882 | 100A | 30.5±1.0 | 400m/1200# | |
| 2×1/0AWG+2AWG+4×16AGW | 10.5/8.2 | 0.349/0.555 | 200A | 38.0±1.0 | 250m/1200# | |
|
2×3/0AWG+1/0AWG (2×3/0AWG+4AWG+6X18AWG)3/0AWG Ground line minimum 4AWG |
13.05/10.5 | 0.219/0.349 | 260A | 45.0±1.0 | 150m/1200# | |
| 4X1-0AWG+4AWG+6X18AWG | 10.4/6.5 | 0.351/0.882/23.6 | 300A/350A | 45.7±1.2 | 150m/1200# | |
| 300V EVJE(TPE) | 3×16AWG | 1.5/1.2 | 3.51/22.4 | 12A | 9.5±0.3 | 1200m/700# |
| 3×14AWG | 1.9/1.2 | 8.88/22.4 | 16A | 10.2±0.5 | 1000m/700# | |
| 3×12AWG | 2.4/1.2 | 5.58/22.4 | 23A | 11.4±0.5 | 800m/700# | |
| 3×16AWG+1×18AWG | 1.5/1.2 | 3.51/22.4 | 12A | 10.5±0.5 | 1000m/700# | |
| 3×14AWG+1×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 11.1±0.5 | 80m/700# | |
| 3×12AWG+1×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 12.2±0.5 | 500m/700# | |
| 3×16AWG+2×18AWG | 1.5/1.2 | 3.51/22.4 | 12A | 11.3±0.5 | 800m/700# | |
| 3×14AWG+2×18AWG | 1.9/1.2 | 8.88/22.4 | 16A | 12.0±0.5 | 800m/700# | |
| 3×12AWG+2×18AWG | 2.4/1.2 | 5.58/22.4 | 23A | 13.1±0.5 | 500m/700# | |
| The number of signal wires can be 0~6, or more, the signal wire conductor specifications can be 16AWG, 18AWG, 20AWG, 22AWG. | ||||||
The above product specifications, sizes, and structures may be changed due to technological progress. Similar specifications can be designed and manufactured according to customer needs.
Send Inquiry to This Supplier
You May Also Like
-
OMG' EV Charging Cable 1000V EN 50620 H07BZ5-F for Electric Vehicle Charging ConnectorNegotiableMOQ: 300 Meters
-
OMG EV CABLE (IEC 62893) 450/750V AC Electric Vehicle Charging Cable (62893IEC121 62893IEC123)NegotiableMOQ: 300 Meters
-
1500V DC EV Charging Cable - IEC 62893 Compliant | OMG EV CABLENegotiableMOQ: 300 Meters
-
IEC 62893 High Power 1500V DC EV Charging Cable for Fast ChargersNegotiableMOQ: 300 Meters
-
UL 2263 EV Charging Cable | Flexible TPE/PVC Electric Vehicle CableNegotiableMOQ: 300 Meters
-
Water-Cooled High Power Charging (HPC) Cable 700A 1500V DC for EV Fast ChargingNegotiableMOQ: 300 Meters
-
NACS Charging CableNegotiableMOQ: 50 Meters
-
EN 50620、IEC62893 AC Charging CableNegotiableMOQ: 50 Meters
-
Oil-cooled EV Charging CableNegotiableMOQ: 50 Meters
-
OMG EV In-Car High-Voltage Cable – ISO 19642, LV216, XLPE, XLPO, OrangeNegotiableMOQ: 300 Meters