Module Spare Parts 1407-CGCMC
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 1407-CGCMC |
Increase O2 is used to increase the amount of oxygen delivered to the patient to prevent low oxygen saturation levels. 1. Select as a Favorite (the procedure will start immediately - see "Setting Favorites" in the Operation section), or select Menu > Procedures > Increase O2, or press the Increase O2 hard key. 2. Use the facility set increase O2% (factory default value is +25% for neonatal or 100% for pediatric and adult) or adjust the O2% to the desired concentration and confirm the setting. 3. Select Start. • The oxygenation general message shows along with the progress bar and a 2 minute countdown timer. The progress bar fills in proportion to the amount of time the Increase O2 procedure has completed. • The procedure will end when the time has elapsed or when Stop is selected, or when the Increase O2 Favorite is selected, or when the Increase O2 hard key is pressed. CARESCAPE™ R860 7-6 2065490-001 Performing an Inspiratory Hold The Inspiratory Hold procedure may be used during an x-ray procedure or to determine plateau pressure and static compliance calculations. When Inspiratory Hold is selected the inspiratory and expiratory valves close at the end of the next inspiratory phase. The Inspiratory Hold cannot be repeated until the patient triggers a spontaneous breath or the ventilator delivers a mandatory breath. Inspiratory Hold is not available in non-invasive ventilation modes. 1. Select as a Favorite (the procedure will start immediately) - see "Setting Favorites" in the Operation section or select Menu >Procedures >Inspiratory Hold. 2. Select the Inspiratory Hold Time. • Use the Trim Knob to select an Inspiratory Hold time: 2 to 40 seconds for adult, 2-15 seconds for pediatric and neonatal. 3. Select Start. • A general message shows while the inspiratory hold is in progress. • The procedure will end when the Hold Time has elapsed or when Stop is selected. • Pplat and Cstat results will display along with a timestamp. If the measurement is not available, a red X will display indicating a failure
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 1756-CNBUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1756-EN2TXTUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1756-EWEBUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1756-IF16US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1756-RM AUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1786-RPFPXLBUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1794-ASBUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts9300 9852 9802US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 9300 9852 9852US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 9662-610 3000520-390C1RUS$ 1 - 100000MOQ: 1 Piece