Module Spare Parts 1756-EN2TXT

Module Spare Parts 1756-EN2TXT photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
A-B
Model Number:
1756-EN2TXT
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name A-B
Model Number 1756-EN2TXT


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands

1756-EN2TXT

EtO2 high Medium End tidal O2 measured by the airway module is greater than the EtO2 high alarm limit. End tidal O2 is greater than the high alarm limit. • Check for additional O2 flow into the patient circuit. • Review the ventilator settings. • Review the EtO2 high alarm limit in Alarm Setup. EtO2 low Medium End Tidal O2 measured by the airway module is less than the EtO2 low alarm limit. End tidal O2 is less than the low alarm limit. • Check for leaks in the patient circuit or airway. • Check the airway module gas sampling line connection. • Check for an occlusion in the airway module gas sampling line. • Review the ventilator settings. • Review the EtO2 low alarm limit in Alarm Setup. Expiratory flow sensor error High Expiratory flow sensor communications failed. The ventilator is not receiving data from the expiratory flow sensor. Flow and volume measurements may not be available. • Replace the expiratory flow sensor. • Contact an authorized service representative. The Expiratory flow sensor is not connected. The expiratory flow sensor is not detected. • Install the expiratory flow sensor. • Check the expiratory flow sensor connection. • Replace the expiratory flow sensor. Medium4 • For an Adult or Pediatric patient, measured expired tidal volume is greater than the measured inspired tidal volume by 20% or 100 ml, whichever is greater for 6 consecutive breaths.

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs