Module spare parts 1746SC-IN04I
- 1 Piece / Pieces per Month
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
- IC200CHS006E
- Agent Israel ELMO drive TAM-20/120VAC ELMO new original authentic
- Agent Israel ELMO drive G-OBO13/230FEHN1 ELMO new original authentic
- Agent Israel ELMO drive G-TWI3/100EES ELMO new original authentic
- Agent Israel ELMO drive G-SOLTWID140/100ERSV ELMO new original authentic
- Agent Israel ELMO drive G-SOLTWID40/200SRSD ELMO new original authentic
Product Details
Brand Name: | A-B | Model Number: | 1746SC-IN04I |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
1746SC-IN04I |
Alarm Priority Condition* Cause Action Air and O2 supply pressure low High O2 supply pressure and air supply pressure are less than 24.3 psig for more than 0.5 seconds. Air supply pressure is low and O2 supply pressure is low. • Check the Air and O2 connections. • Check the air source. • Check the O2 source. • Prepare to disconnect the patient from the ventilator and manually ventilate. Air supply pressure high Low Air supply pressure is greater than 95 psig for more than 0.5 seconds. Air supply pressure is high. • Check the air source. • Set FiO2 to 100%. Air supply pressure low Medium4 Air supply pressure is less than 24.3 psig for more than 0.5 seconds. Air supply pressure is low. The ventilator is delivering O2 only. O2 may be leaking into the air supply system. • Check the Air connection. • Check the air source. Air supply pressure sensor error Low Air supply pressure sensor data is invalid during a non-ventilation state. The ventilator is not able to measure air supply pressure. • Perform System Check. • Contact an authorized service representative. • Prepare to disconnect the patient from the ventilator and manually ventilate. Air temperature high High Total flow sensor temperature is above 51° C. Air supply temperature is high. • Check the air source. • Clean the compressor filter. Important Note 8 Alarms and troubleshooting 2065490-001 8-9 Alarm Priority Condition* Cause Action Airway module error Medium4 There is a problem with the installed airway module. Airway module spirometry data is not available while this alarm is active. Some features may not be available. The airway module is not working. CO2 and O2 data are not available. The airway module data is not valid. • Replace the airway module. Low Airway module detected is not compatible with system software. The installed airway module is not compatible with system software. • Remove the airway module. Airway module gas sampling error Medium4 Sample gas outlet of the installed airway module is blocked while the nebulizer is not in use. Occlusion detected in airway module sample gas outlet. • Check for an occlusion in the airway module sample gas outlet. • Wait 30 seconds, and then press Home to resume gas sampling. D-fend module is not detected by the installed airway module while the nebulizer is not in use. Occlusion detected in airway module gas sampling line or D-fend water trap. • Empty the D-fend water trap. • Check for an occlusion in the airway module gas sampling line. • Replace the airway module gas sampling line. Sample tubing inside or outside the installed airway module is blocked or the water trap is occluded. The airway module gas sampling line or the Dfend water trap is not installed. • Install the D-fend water trap. • Check the airway module gas sampling line connection. • Wait 30 seconds, and then press Home to resume gas sampling. Low Residue buildup on the water trap membrane of the installed airway module. Buildup can decrease airflow. Occ
Contact Us
- Xiamen xiongba e-commerce Co., Ltd
ABB | EPRO | PROSOFT | NI |
REXROTH | Schneider | Miscellaneous brand | EMERSON |
SEW | SIEMENS | GE | SST |
A-B | TRICONEX | WATLOW | WOODWARD |
YAMATAKE | YOKOGAWA | HONEYWEL | BENTLY |
FOXBORO | FSC | ENTERASYS | HIMA |
TRIPLEX |
- Agent Israel ELMO drive G-DCTROR22/400SE1 ELMO new original authentic
- Agent Israel ELMO drive G-DCTRO16/400SES ELMO new original authentic
- 6ES7223-1PL32-0XB0 SIMATIC S7-1200 SM 1223 digital input output modules PLC module
- Siemens plc 6ES7 321-1BH02-0AA0 SIMATIC S7-300 Digital input SM 321 6ES73211BH020AA0
- 6ES73211BH020AA0 simen plc S7-1200 I/O module 6ES7321-1BH02-0AA0
- Original ABB TU838 3BSE008572R1 module
- Original ABB 3BSE038415R1 AO810V2 Analog Output 8 ch I/O Modules
- ABB PROFIBUS module CI840A 3BSE041882R1 PROFIBUS DP-V1
- Servo high temperature vacuum hot press Electric cylinder high pressure and high precision vacuum press 450 degrees Celsius, 5 tons, 10 tons
- HAILUNDA GZC-TF21 15.6 inch screen vacuum laminating machine OCA optical glue vacuum pressing machine
- PIONEER MAGNETICS PM3398B-6-1-3-E 80026-172-24 Digital input I/O module
- EMERSON A6740 RELAY MODULE
- EMERSON A6410 Expansion monitoring module
- EMERSON A6210 Axis vibration monitoring card
- EMERSON A6220 monitor module
- EMERSON A6110 Low pressure differential regulator
- GE 369-HI-R-M-F-E-H-E Motor management relay
- VIBRO-METER VM600 RPS6U 200-582-600-013 SCR module
- VIBRO-METER VM600 RLC16 200-570-000-111 200-570-101-015 Relay card
- VIBRO-METER VM600 MPC4 200-510-071-113 200-510-111-034 MPC4 Mechanical Protection Card
- VIBRO-METER VM600 IOCN 200-566-000-112 200-566-101-013 IOCN Card
- VIBRO-METER VM600 IOCN 200-566-000-112 200-566-101-013 IOCN Card
- VIBRO-METER VM600 IOC16T 200-565-000-013 200-565-101-013 I/O module
- VIBRO-METER VM600 IOC4T 200-560-000-111 200-560-101-017 Vibration monitoring and protection system
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-