Module Spare Parts 1747-ASB

Module Spare Parts 1747-ASB photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
A-B
Model Number:
1747-ASB
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name A-B
Model Number 1747-ASB


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands

1747-ASB

rway module sensor error High Peak pressure measured by the airway module is below 3 cmH2O, and is also at least 5 cmH2O below the peak pressure measured by the ventilator. The airway module does not detect pressure or flow. • Install the airway module spirometry sensor between the patient circuit and the patient. • Check the airway module spirometry tube connection. • Remove the neonatal flow sensor. • Set Data Source to Ventilator. Airway pressure sensor error High The difference between expiratory pressure and inspiratory pressure is greater than 10 cmH2O for more than 350 ms. Expiratory pressure is greater than inspiratory pressure. • Check for an occlusion in the expiratory pressure port. • Perform System Check. Expiratory pressure sensor data is invalid. The ventilator is not able to measure expiratory pressure. • Perform System Check. Inspiratory pressure sensor data is invalid. The ventilator is not able to measure inspiratory pressure. • Perform System Check. Low Zeroing of expiratory pressure sensor data was out of range for 3 consecutive zeroing attempts. The ventilator is not able to measure expiratory pressure. • Perform System Check. Zeroing of inspiratory pressure sensor data was out of range for 3 consecutive zeroing attempts. The ventilator is not able to measure inspiratory pressure. • Perform System Check. Alarm light error Medium4 An error was detected with the alarm light. The alarm light is not working. • Cycle power. • Contact an authorized service representative. Apnea High1, 2 No valid breaths were detected for the set Apnea Time. Expired tidal volume not detected within the set Apnea Time. • Check the status of the patient. • Check for leaks in the patient circuit or airway. • Review the Apnea Time setting in Alarm Setup. Apnea alarm off Medium4 Apnea Time selection is Off. Apnea Time is set to Off. • Review the Apnea Time setting in Alarm S

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs