Module Spare Parts 1786-RPFPXLB

Module Spare Parts 1786-RPFPXLB photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
A-B
Model Number:
1786-RPFPXLB
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name A-B
Model Number 1786-RPFPXLB


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands

1786-RPFPXLB

O2 supply pressure sensor error Low O2 supply pressure sensor data is invalid while not in therapy. The ventilator is not able to measure O2 supply pressure. • Perform System Check. • Contact an authorized service representative. Patient circuit occluded High An occlusion in the patient circuit was detected. Inspiratory pressure is greater than expiratory pressure. • Check for an occlusion in the patient circuit. • Check for an occlusion in the patient circuit filters. • Check for an occlusion in the expiratory flow sensor. • Replace inspiratory safety guard. Patient connection leak High Leak measured by the neonatal flow sensor is greater than the set leak limit. Leak % is greater than the set Leak Limit. • Check for leaks in the patient airway. • Review the Leak Limit setting in Alarm Setup. • Clean or replace the neonatal flow sensor. Patient detected High A patient connection is detected while in Standby with the circuit not parked. A patient connection is detected. • Start ventilation if a patient is connected. • Select Park Circuit if a patient is not connected. Patient disconnected High Patient is disconnected. Low expiratory pressure or flow detected. • Check the status of the patient. • Check for leaks in the patient circuit or airway. • Review the Tdisconnect setting in Alarm Setup. Low Patient is disconnected while in a non-invasive vent mode prior to the Tdisconnect time. Low expiratory pressure or flow detected. • Check the status of the patient. • Check for leaks in the patient circuit. • Review the Tdisconnect setting in Alarm Setup. Paux high Medium Auxiliary pressure is greater than the Paux high alarm limit. Paux is greater than the high alarm limit • Review the Paux high alarm limit in Alarm Setup

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs