Module Spare Parts 1786-RPFPXLB
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 1786-RPFPXLB |
O2 supply pressure sensor error Low O2 supply pressure sensor data is invalid while not in therapy. The ventilator is not able to measure O2 supply pressure. • Perform System Check. • Contact an authorized service representative. Patient circuit occluded High An occlusion in the patient circuit was detected. Inspiratory pressure is greater than expiratory pressure. • Check for an occlusion in the patient circuit. • Check for an occlusion in the patient circuit filters. • Check for an occlusion in the expiratory flow sensor. • Replace inspiratory safety guard. Patient connection leak High Leak measured by the neonatal flow sensor is greater than the set leak limit. Leak % is greater than the set Leak Limit. • Check for leaks in the patient airway. • Review the Leak Limit setting in Alarm Setup. • Clean or replace the neonatal flow sensor. Patient detected High A patient connection is detected while in Standby with the circuit not parked. A patient connection is detected. • Start ventilation if a patient is connected. • Select Park Circuit if a patient is not connected. Patient disconnected High Patient is disconnected. Low expiratory pressure or flow detected. • Check the status of the patient. • Check for leaks in the patient circuit or airway. • Review the Tdisconnect setting in Alarm Setup. Low Patient is disconnected while in a non-invasive vent mode prior to the Tdisconnect time. Low expiratory pressure or flow detected. • Check the status of the patient. • Check for leaks in the patient circuit. • Review the Tdisconnect setting in Alarm Setup. Paux high Medium Auxiliary pressure is greater than the Paux high alarm limit. Paux is greater than the high alarm limit • Review the Paux high alarm limit in Alarm Setup
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts T8151BUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T8231US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T8310US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T8431CUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T8830US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T9110US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T9402US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T9432US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T9451US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts T9481US$ 1 - 100000MOQ: 1 Piece