Key Specifications
Get Latest Price
Business Type:
Distributor/Wholesaler
Year Established:
2015
Annual Export Value:
Below US$1 Million
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Product Description

China factory Price hot sales AAS Atomic Absorption Spectrophotometer AA320N

The specification for China factory Price hot sales AAS Atomic Absorption Spectrophotometer AA320N:
Characteristics A:

China factory Price hot sales AAS Atomic Absorption Spectrophotometer AA320N
1. Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC. 2. Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples. 3.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration 4. Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit.Therefore the light flux of double beam is enhanced. 5.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling. 6.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation. 7.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame . 8.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
Characteristics B

China factory Price hot sales AAS Atomic Absorption Spectrophotometer AA320N
1. Light-source system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply:with fixed current 2.Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm 3.Flame atomization system: Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices. 4.Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.
More Details Photos
Specification
Working spectral range:
190-900nm
Wavelength accuracy:
≤ ±0.5nm
Wavelength repeatability:
≤ 0.3nm (single direction)
Spectrum bandwidth:
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution:
<40%
Base line stability:
±0.004Abs/30min
Characteristic concentration of copper:
≤ 0.04mg/ml/1%
Detection limit of copper:
≤0.008mg/ml
Background calibration ability:
Greater than 30 times.
Standby Interface:
RS 232
Instrument power supply:
220V, 3A, 50Hz

Accessory for China factory Price hot sales AAS Atomic Absorption Spectrophotometer AA320N:

Main accessories supplied with the instrument: Several decades of accessories including air compressor,

one piece of Cu hollow

cathode lamp. Gas external pipe, acetylene cylinder pressure-reducing valve and water knockout gas filter.

GA3202 HGA graphite furnace system

Used to conduct trace and ultra-trace analysis with an absolute sensitivity of 10-10-10-12 gram. Technical data:
1 Temperature range:20℃~3000℃ 2 Light controlling temperature range:1500℃~3000℃ 3 Heating rate:3000℃/S 4 Graphite furnace characteristics:Cu≤1×10-10g  Cd≤1×10-12g 5 Precision:Cu≤14%  Cd≤5% 6 Detection limit:Cu≤2×10-12g 7 Analysis precision is superior to the national standard

Hydride generator AAH-1

Using AAH1 generator and atomic absorption spectrophotometer, the determination of trace arsenic, selenium, lead, tin, hoof and cold atomic absorption spectrometry in the sample set by hydride atomic absorption spectrometry was used to determine the element of fixed mercury.
Test metod
Continuous flow injection
Reducing agent
МаВH4
Sample inflow rate
0-7mL/ min
Reagent inflow rate
0-2.5mL/min
The burner
Heated quartz tube (heated by acetylene combustion)
The carrier gas
Ar, Gas supply pressure 0.32Mpa
Powder
220V, 50HZ, 30W
Size
290*220*208mm
Recommend Products
Packing & Delivery
Company Profile
Customer Concerns
Contact Us

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Distributor/Wholesaler
Year Established
2015
Annual Export Value
Below US$1 Million
Main Markets
Southern Europe, Northern Europe, Central America, Western Europe, Eastern Asia, Mid East, Oceania, Africa, Southeast Asia, Eastern Europe, South America, North America