Veterinary SF100BY 100mA Mobile x Ray Equipment for Radiography CE
Advantages
This efficiency-improved x ray equipment takes the following advantages:
1. Adopts high-pressure silicon, full-wave rectification technology.
2. With kilovolt (kV), milliampere (mA) and time (s ) three factors interlocks control system
3. Overloading indicator & the protection circuit of excessive voltage & insufficient voltage, thus the X ray tube head of x ray will not be damaged because of mis-operating.
4. Equipped with steady filament voltage circuit to control the X ray dosage while photographing
5. Remotely controlled exposure & manually controlled exposure options
6. Sound & flash indicator while exposing for patients & medical personnel convenience
7. This x ray machine equipped the electricbeam limiter with shadow positioning. The electric beam limiter will send out a beam of visual light while operating to aim the nidus and the scale ofthe visual
light overlaps the scale of X ray exposing. This function make it convenient that medical personnel position
the nidus & the x ray exposed area.
8. Movable cantilever sliding in vertical direction so that it is flexible to adjust the Xray tube head to appropriate angle &height. When the complete machine is moved, the cantilever of theXray tube head can be set to the
min. position and lock, safely and conveniently.
Main Technical Conditions
1. This machine is a single focus point, full-wave rectification bedside X ray medical diagnosis machine
2. Maximum Ratings:
|
mA kVp s
kV S |
~3.2
|
~4.0 |
~6.3 |
16 |
90 |
90 |
90 |
32 |
90 |
90 |
90 |
63 |
90 |
90 |
|
100 |
80 |
3. Condition of the power supply
Single-phase alternating current Voltage: 180V-250V Frequency: 50Hz Power supply resistance ≤0.2Ω Instantaneous electric current: 37A (Max)
4. Timer 0.08-6.3s, 20 shelves of electron type 5. X ray tube specification : XD4-29/100, focus 4.3
6.X ray tube focus highest position (above ground level)≥1710mm
X ray tube focus lowest position (above ground level)≤480mm
7.Remotely exposure distance: 6m 8. The required pulling force to move the whole machine≤25kg
9. Power of Electric Beam Limiting Device: AC 24V, Capacity 110W.
10. Indicator Power of Electric Beam Limiting Device: AC 24V, Power: 100W, Tungsten Haloid Light
11. Illuminance of Electric Beam Limiting Device: no less than 100Lx at 1m from X ray focus to target area
12. When X ray focus at 650mm away from the film, max illumination scale ≤350mm×350mm;
When X ray focus at 1m away from the film, max illumination scale ≤50mm×50mm
Certificate&Warranty&service
CE, ISO, FSC; 12 months from the date of shipment;
Best after-sale service, technical support forever.
Mobile X ray equipment suitable for veterinary
50mA mobile x ray equipment model SF50BY with ISO, CE, FSC certified; 70mA mobile x ray equipment model SF70BY with CE, ISO, FSC certified; 100mA mobile x ray equipment model SF100BY with CE, FSC, ISO certified.
Send Inquiry to This Supplier
You May Also Like
-
70mA SF70BY Medical X-ray for AnimalNegotiableMOQ: 1 Set
-
SF100BG 100mA Photography X-ray Machine Human and VeterinaryNegotiableMOQ: 1 Set
-
RX2210 High Frequency Digital X-ray Radiography SystemNegotiableMOQ: 1 Unit
-
RX2211 High Frequency Digital X-ray Radiography SystemNegotiableMOQ: 1 Unit
-
RX2310C High Frequency Mobile C-arm SystemNegotiableMOQ: 1 Unit
-
RX2310B High Frequency Mobile Digital C-arm SystemNegotiableMOQ: 1 Unit
-
RX2310B High Frequency Mobile C-arm SystemNegotiableMOQ: 1 Unit
-
RX2310C High Frequency Mobile Digital C-arm SystemNegotiableMOQ: 1 Unit
-
RX2212 High Frequency X-ray Radiography SystemNegotiableMOQ: 1 Unit
-
100mA X-ray Tube XD4-2.9/100NegotiableMOQ: 1 Set