Brand Name | WEPOWER ELECTRONIC | Place of Origin | China |
Product Description
The vortex gas flow meter follows the basic and practical Carmen principle, the vortex flow meter is simple in structure and easy to install. When installing, the customer installs according to the direction of the arrow posted on the main body of the vortex flow meter, and the plane of the triangular column is the medium inlet.
The main body of the Vortex gas flow meter is fully welded, and the main body material is 304 or 316. Because of the completely welded method, users do not have to worry about the internal parts falling off when using the vortex gas flow meter. The surface of the vortex meter is smooth and the measurement is not hindered. Vortex gas flow meter has multiple power supply methods. Users can choose special lithium battery power supply models (not commonly used) or 24VDC or 12VDC. Generally speaking, the normal pressure range during operation is 1.6MPa, 2.5MPa, 4.0MPa
Name | Vortex Flow Meter For Gas |
Medium | Steam, compressed air, coal gas, liquid and other high-velocity medium |
Accuracy for gas or steam | ±1.5%(standard) |
Communication | RS485/Modbus, Hart, Profitbus |
Flange standard | GB, ANSI, JIS |
Flange & wafer range | DN15-DN300 |
Velocity range | 4.0~60m/s gas; 5.0~70m/s |
Body material | SS304, SS316(option) |
Medium temperature | Normal type is -40°C~280°C, high temperature type is -40°C~350°C |
Relative humidity | ≤85% |
Protection grade | IP65 |
What are the precautions when installing Vortex gas flow meter?
● Generally, we recommend that users install the vortex gas flow meter indoors, as the unstable outdoor temperature may cause safety hazards.
● When using the vortex flow sensor, it should not be installed at the inlet and outlet of the pump. The oscillating fluid often generated at the pump mouth will affect the measurement of the vortex flow meter.
● The inner diameter of the pipe to be measured needs to be the same as the inner diameter of the flow meter, and the flange welding at both ends of the vortex flow meter should ensure parallel.
● The signal output line of vortex shedding flow meter should be separated from the power line, if the signal line and power line are laid in the same trench, the signal line should be protected by a separate metal pipe shield.
Certificate & Other Products:
Welcome to visit the Wepower website for more products information about flow meters, pressure transmitters, thermometers, level meter and density meter.
Contact Us
- Yantai Wepower Electronic Co., Ltd
- Contact nameWepower-K Chat Now
- AddressETDZ No.5 Hengshan road, Yantai, Shandong
Product Categories
New Products
-
Economical 80GHz Tank Radar Level Transmitter
-
80GHz Radar Level Sensor For Solid And Powder
-
Reed Type Level Sensor RS485
-
Magnetic Float Switch For Diesel
-
Magnetic Type Level Transmitter
-
Reed Type Level Switch
-
Magnetic Float Level Gauge With 4-20mA
-
Level Sensor For Acid Liquid Tanks
-
Float Type Level Indicator
-
Magnetic Level Sensor
-
Borewell Water Level Indicator
-
Water Level Indicator Meter
Popular Searches
- air flow meter
- Flow Meter Sensor
- digital display
- gas flowmeter
- Milk Flow Meter
- Flow Meter Flowmeter
- Stainless Steel Flowmeter
- Flow Meter Vortex Flowmeter
- Compressed Air Flowmeter
- air flow meter
- Water Flow Meter
- Turbine Flow Meter
- Liquid Flow Meter
- Natural Gas Flow Meter
- Steam Flow Meter
- Air Mass Flow Meter
- Milk Flow Meter
- Biogas Flow Meter
- Nitrogen Flow Meter
Recommended Products
- Alicat MWB Low Pressure Loss Series Portable Series Gas Mass Flow Meter
- Alicat MB Series Portable Series Gas Mass Flow Meter
- Alicat Standard M-Series Gas Mass Flow Meter
- Alicat MC Standard Series Gas Mass Flow Controller
- Ufm/universal flow monitors flow switch MN-DSF300LM-16-1050
- Siemens 840D Handwheel 6FX2007-1AC04/1AE14/1AC14/1AC04 CNC Pendant Unit Currently
- Siemens7ML1998-5NE11/MANUAL, SITRANS LUT400 COMMUNICATIONS, FRENCH
- 7ML1998-5NE01/MANUAL, SITRANS LUT400 COMMUNICATIONS, ENGLISH
- 7ML5740-2AA11-0A/Universal input, panel-mounted digital display. RD200, power supply 12-36 V DC, MODBUS.
- 7ML5740-2AC01-1A/ IS A UNIVERSAL INPUT, PANEL MOUNT REMOTE DIGITAL DISPLAY FOR PROCESS INSTRUMENTATION. RD200 12-36 VDC DISPLAY WITH 4-20,2X
- 7ML5811-1A/up to 20 relay outputs, switchable AC/DC power supply, certifications CSA NRTL/C, FM, CE.
- 7ML5740-2AC01-1A/THE SITRANS RD200 IS A UNIVERSAL INPUT, PANEL MOUNT REMOTE DIGITAL DISPLAY FOR PROCESS INSTRUMENTATION. RD200 12-36 VDC DISPLAY
Find Similar Products By Category
- Instruments & Meters > Meter for Liquid & Gas > Flow Meter
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Wepower-K
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile