Home > Instruments & Meters > Test Instrument > Test Machine > DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath

DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath

DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath photo-1
DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath photo-2
DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath photo-3
DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath photo-4
DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath photo-5
DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath photo-6
US$ 1200 - 2500 MOQ: 1 Set
Key Specifications
Get Latest Price
Warranty:
1 year
brand name:
HST OR OEM
place of origin:
Shandong, China
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Warranty 1 year
brand name HST OR OEM
place of origin Shandong, China
customized support OEM, ODM, OBM
power Electronic
warranty 1 YEAR
model number DWC
Power 7KW
Cooling Medium Ethanol or other unfrozen liquid
Mode of refrigeration Compressor refrigeration
Box Material Steel Spray
Cold Room Volume 150*505*240mm
Temperature Control Accuracy ±0.5°
Function low temperature make
Color White
Accuracy class 1
Certification Reach, ce, iso

DWC 40/60/80/100  Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling bath  

 DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath

Product Description

 

1. Application

The mechine is designed according to Charpy notch Impact Test Method for Metal Material, and adopts compressor cooling technology. It utilizes the heat balance principle and cycle stirring method to realize the constant temperature cooling to impact specimen with the reliable performance. Digital display, automatic control temperature, and it is the ideal equipment for cooling and keeping temperature to impact specime

 

2.Features:

2.1Imported compressor, DANFUS valve, imported evaporation-condensation machine;

2.2Controlled by intellligent instrument, digital presentation temperature value, automatic control temperature, automatic time and alarm.

2.3high security, refrigerate fast, large volume

 

3.Main Specifications:

 

Model

DWC-40

DWC-60

DWC-80

 

DWC-100

Temperature range

+30~-40°

+30~-60°

+30~-80°

+30~-100°

Temperature Control Accuracy

±0.5°

Temperature dropping speed

 

+30°C~0°C

1.2°C/min

+30°C~0°C

2°C/min

+30°C~0°C

2°C/min

+30°C~0°C

2°C/min

0°c~-20°C

0.8°C/min

0°c~-20°C

1.5°C/min

0°c~-20°C

1.5°C/min

0°c~-20°C

1.5°C/min

-20°C~-40°C

0.5°C/min

-20°C~-40°C

1.0°C/min

-20°C~-60°C

1.0°C/min

-20°C~-40°C

1.0°C/min

-40°C~-60°C

0.7°C/min

-60°C~-80°C

0.7°C/min

-60°C~-100°C

0.7°C/min

Cold Room Volume

150×505×240mm

Dimensions

900×505×850 mm

 

900×505×850 mm

 

900×505×850 mm

 

1500×1200×1200 mm

 

Box Material

Steel Spray

Loading the number of samples

>60

>60

>60

>200

Mode of refrigeration

Compressor refrigeration

Cooling Medium

Ethanol or other unfrozen liquid

Power

7Kw

7Kw

7Kw

7Kw

 DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath

More Information

DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath

DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath DWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling BathDWC 40/60/80/100 Low Temperature Chamber for Charpy Impact Test + Cooling Chamber+Chiller+Cooling Bath 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Manufacturer
Year Established
2009
Factory Size
1,000-3,000 square meters
Annual Export Value
US$10 Million - US$50 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs