Module Spare Parts 1C31166G01
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 1C31166G01 |
Select Alarm Setup and set the EtCO2 low and EtCO2 high alarm limits to Off. • Verify the EtCO2 low alarm no longer sounds. • Verify the EtCO2 low alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes. High EtCO2 alarm test This test requires an installed and warmed-up airway module with CO2 monitoring capabilities. 1. Set the vent mode to A/C VC. 2. Select START VENTILATION > Continue. 3. Add CO2 into the inspiratory limb to get an EtCO2 value between 5% and 10%. 4. Select Alarm Setup and set the EtCO2 low alarm limit to 1 and the EtCO2 high alarm limit to 4. • Verify the high priority EtCO2 high alarm sounds. • Verify the EtCO2 high alarm shows with a red background in the alarm bar. • Verify the display unit alarm light flashes red. 5. Select Alarm Setup and set the EtCO2 low and EtCO2 high alarm limits to Off. • Verify the EtCO2 high alarm no longer sounds. • Verify the EtCO2 high alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes. PEEPe low alarm test 1. Set vent mode to A/C VC. 2. Use the quick key to set PEEP to 5 cmH2O. 3. Select START VENTILATION > Continue. 4. Select Alarm Setup and set the PEEPe high alarm limit to Off and the PEEPe low alarm limit to 15 cmH2O. • Verify the medium priority PEEPe low alarm sounds. • Verify the PEEPe low alarm shows with a yellow background in the alarm bar. 8 Alarms and troubleshooting 2065490-001 8-31 • Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the PEEPe low alarm limit to Off. • Verify the PEEPe low alarm no longer sounds. • Verify the PEEPe low alarm no longer shows in the alarm bar. • Verify the display unit alarm light no longer flashes. PEEPe high alarm test 1. Set the vent mode to A/C VC. 2. Use the quick key to set PEEP to 20 cmH2O. 3. Select START VENTILATION > Continue. 4. Select Alarm Setup and set the PEEPe low alarm limit to 2 and the PEEPe high alarm limit to 5. • Verify the medium priority PEEPe high alarm sounds. • Verify the PEEPe high alarm shows with a yellow background in the alarm bar. • Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the PEEPe low and high alarm limits to Off. • Verify the PEEPe high alarm no longer sounds. • Verify the PEEPe high alarm no longer shows in the alarm bar. • Verify the display unit alarm light no longer flashesight flashes red
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 1C31219G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31222G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1TGE120021R0010US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 200-510-017-017 200-510-111-013US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 200-566-000-012 200-566-101-012US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 200-595-002-011US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216AB61 HESG324013R0100 HESG435572P1US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216DB61 HESG324063R0100 HESG216882AUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216EA61b HESG324015R1 KHESG324258R3I HESG448230R1US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 8115-DO-DCUS$ 1 - 100000MOQ: 1 Piece