Module Spare Parts 1C31166G01

Module Spare Parts 1C31166G01 photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
GE
Model Number:
1C31166G01
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name GE
Model Number 1C31166G01


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands

1C31166G01

Select Alarm Setup and set the EtCO2 low and EtCO2 high alarm limits to Off. • Verify the EtCO2 low alarm no longer sounds. • Verify the EtCO2 low alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes. High EtCO2 alarm test This test requires an installed and warmed-up airway module with CO2 monitoring capabilities. 1. Set the vent mode to A/C VC. 2. Select START VENTILATION > Continue. 3. Add CO2 into the inspiratory limb to get an EtCO2 value between 5% and 10%. 4. Select Alarm Setup and set the EtCO2 low alarm limit to 1 and the EtCO2 high alarm limit to 4. • Verify the high priority EtCO2 high alarm sounds. • Verify the EtCO2 high alarm shows with a red background in the alarm bar. • Verify the display unit alarm light flashes red. 5. Select Alarm Setup and set the EtCO2 low and EtCO2 high alarm limits to Off. • Verify the EtCO2 high alarm no longer sounds. • Verify the EtCO2 high alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes. PEEPe low alarm test 1. Set vent mode to A/C VC. 2. Use the quick key to set PEEP to 5 cmH2O. 3. Select START VENTILATION > Continue. 4. Select Alarm Setup and set the PEEPe high alarm limit to Off and the PEEPe low alarm limit to 15 cmH2O. • Verify the medium priority PEEPe low alarm sounds. • Verify the PEEPe low alarm shows with a yellow background in the alarm bar. 8 Alarms and troubleshooting 2065490-001 8-31 • Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the PEEPe low alarm limit to Off. • Verify the PEEPe low alarm no longer sounds. • Verify the PEEPe low alarm no longer shows in the alarm bar. • Verify the display unit alarm light no longer flashes. PEEPe high alarm test 1. Set the vent mode to A/C VC. 2. Use the quick key to set PEEP to 20 cmH2O. 3. Select START VENTILATION > Continue. 4. Select Alarm Setup and set the PEEPe low alarm limit to 2 and the PEEPe high alarm limit to 5. • Verify the medium priority PEEPe high alarm sounds. • Verify the PEEPe high alarm shows with a yellow background in the alarm bar. • Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the PEEPe low and high alarm limits to Off. • Verify the PEEPe high alarm no longer sounds. • Verify the PEEPe high alarm no longer shows in the alarm bar. • Verify the display unit alarm light no longer flashesight flashes red

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs