Module Spare Parts 1C31166G02

Module Spare Parts 1C31166G02 photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
GE
Model Number:
1C31166G02
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name GE
Model Number 1C31166G02


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands

1C31166G02

1. Set vent mode to A/C VC. 2. Use the quick key to set VT to 500 ml. 3. Select START VENTILATION > Continue. 4. Select Alarm Setup and set the VTexp high alarm limit to 700 and the VTexp low alarm limit to 600. The VTExp low alarm becomes active after three breaths. • Verify the medium priority VTexp low alarm sounds. • Verify the VTexp low alarm shows with a yellow background in the alarm bar. • Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the VTexp low alarm limit to 300. CARESCAPE™ R860 8-32 2065490-001 • Verify the VTexp low alarm no longer sounds. • Verify the VTexp low alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes. VTexp high alarm test 1. Set vent mode to A/C VC. 2. Use the quick key to set VT to 500 ml. 3. Select START VENTILATION > Continue. 4. Select Alarm Setup and set the VTexp low alarm limit to 200 and the VTexp high alarm limit to 300. • Verify the medium priority VTexp high alarm sounds. • Verify the VTexp high alarm shows with a yellow background in the alarm bar. • Verify the display unit alarm light flashes yellow. 5. Select Alarm Setup and set the VTexp high alarm limit to 700. • Verify the VTexp high alarm no longer sounds. • Verify the VTexp high alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes. Pmax alarm test 1. Set the vent mode to A/C VC. 2. Select START VENTILATION > Continue. 3. Select Alarm Setup and set the Pmax alarm limit less than the measured Ppeak. • Verify the high priority Ppeak high alarm sounds. • Verify the Ppeak high alarm shows with a red background in the alarm bar. • Verify the display unit alarm light flashes red. 4. Increase the Pmax alarm limit to remove the alarm condition. • Verify the Ppeak high alarm no longer sounds. • Verify the Ppeak high alarm shows with a grey background in the alarm bar. • Verify the display unit alarm light no longer flashes

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs