4301-MBP-DFCM
- 160 Piece / Pieces per Month
- T/T
- 1 days
You May Like
Product Details
Brand Name | PROSOFT | Place of Origin | China | |
Model Number | 4301-MBP-DFCM |
Product Description
Brand:PROSOFT
Type:4301-MBP-DFCM
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Enter the droop percentage followed by the ENTER key. Typically set between 4-6% and not more than 10%. If droop is required, the unit must be programmed as a ‘Generator Application’. RATED SPEED SETPOINT (RPM) dflt= 3600 (0.0, 20000) Set the generator’s rated speed setpoint followed by the ENTER key. (Must be greater than or equal to the ‘Minimum Governor Speed’ Setting and less than the ‘Maximum governor Speed’ Setting)) USE FREQ ARM/DISARM? dflt= NO (Yes/No) Set to YES is using frequency control arm/disarm followed by the ENTER key. If YES, frequency control must be armed before the unit will switch into frequency control. If NO, frequency control is always armed and the unit will go into frequency control whenever the generator breaker is closed and the utility tie breaker is open. (Cannot program both Freq Arm/Disarm and Loadsharing) USE LOCAL/REMOTE? dflt= NO (Yes/No) Set to YES if using Local/Remote control logic followed by the ENTER key. If YES, permits the unit to go from REMOTE (Modbus, contact input and front panel) control to LOCAL (front panel) control only. If NO, all programmed inputs are active at all times. Refer to the Service Mode information in Volume 2 for additional settings on the Local/Remote function. Extraction / Admission Control When this header appears in the display, press the down arrow key to configure this block or press a left or right arrow key to select another block to configure. LOST E/A INPUT = TRIP? dflt= NO (Yes/No) Set to YES if the unit is to trip on loss of extraction/admission analog input signal. LOST E/A INPUT = MAX LP? dflt= NO (Yes/No) Set to YES if LP valve output is to go to maximum (100%) on loss of extraction/ admission analog input signal.
LOST E/A INPUT = MIN LP? dflt= NO (Yes/No) Set to YES if LP valve output is to go to minimum (0%) on loss of extraction/ admission analog input signal. NOTE If the Response to all ‘Lost E/A Input’ questions is “NO”, the 505E will disable extraction/admission control and switch to manual setpoint at the last demand value. INVERT EXTR/ADM INPUT? dflt= NO (Yes/No) Select YES followed by ENTER if Ext/Adm control will be reverse acting. If NO, control will be forward acting. Typically this will be set to NO; when programmed for Coupled HP & LP, Decoupled Inlet, or Decoupled Exhaust modes the only time this input would be inverted is if the LP valve needs to close when the input exceeds the setpoint (the ratio logic provides an inversion ). When programmed for the Decoupled HP & LP modes, this value is set to YES if the LP valve output needs to open when the input exceeds the setpoint (the ratioing logic is not providing an inversion). MIN EXTR/ADM SETPT dflt= 0.0 (-20000, 20000) Set the minimum extr/adm setpoint followed by ENTER. This value is the minimum setpoint value that the extr/adm setpoint can be decreased/lowered to (lower limit of extr/adm setpoint). MAX EXTR/ADM SETPT dflt= 100 (-20000, 20000) Set the maximum extr/adm setpoint followed by ENTER. This value is the maximum setpoint value that the extr/adm setpoint can be increased/raised to (upper limit of extr/adm setpoint). (Must be greater than the ‘Min Extr/Adm Setpt’ Setting) SETPT RATE (units/sec dflt= 5.0 (0.01, 1000) Set the extr/adm setpoint rate followed by ENTER. This value is the rate (in units per second) at which extr/adm setpoint moves when adjusted. SETPT INITIAL VALUE (UNITS) dflt= 100 (-20000, 20000)
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
-
HONEYWELL 51402455-100 MP-DNCF02-200
-
HONEYWELL 51402455-100 MP-DNCF02-201
-
HONEYWELL 51403519-160 K4LCN-16
-
HONEYWELL 51403645-100 SBHM
-
LAM 810-800082-043
-
S21260-SRS
-
IS200SRTDH2ACB
-
IS220PAICH2A 336A4940CSP11
-
IS220PDIAH1A 336A4940CSP1
-
IS220PDOAH1A 3364940CSP2
-
IS220PRTDH1BC 336A5026ADP13
-
IS230SNRTH2A
Popular Searches
- food processor
- log splitter
- network switch
- network hardware
- cisco module
- industrial computer
- poe splitter
- poe
- poe injector
- cisco
- motherboard
- network equipment
- firewall
- video wall processor
- Audio Processor
- cisco network module
- interface processor
- plug-in module
- route
- led module
- Led Lighting
- laser machine
- fiber optic
- ftth
- diode
- laser equipment
- Laser Diode
- laser module
- media converter
- sfp transceiver
Recommended Products
- ABB 89AS30 GKWN000317R0100
- Bently Nevada 330101-00-27-10-02-00
- Prosoft PLX32-EIP-MBTCP
- ABB G2E140-PI51-09
- Siemens 6ES7590-1AB60-0AA0
- Bently Nevada 16710-12
- ICS Triplex T8290C
- Schneider Electric PN072546P702
- Emerson A6500-UM
- Yokogawa NFCP501-W16 S1
- Siemens 6ES7960-1AA06-0XA0
- ABB XVC772A102,3BHE032285R0102
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile