Home > Electrical & Electronics > Power Transmission & Transformer > Transformer > HONEYWELL 51402455-100 MP-DNCF02-200

HONEYWELL 51402455-100 MP-DNCF02-200

HONEYWELL 51402455-100 MP-DNCF02-200 photo-1
US$ 1061 - 2051 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
HONEYWELL
Place of Origin:
China
Model Number:
51402455-100 MP-DNCF02-200
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name HONEYWELL
Place of Origin China
Model Number 51402455-100 MP-DNCF02-200

Brand: HONEYWELL

Type:51402455-100 MP-DNCF02-200

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

Sync Enabled Extr/Adm Priority Active Sync / Load Share Active Steam Map Limiter in Control Load Share Control F3 Key Selected Extr/Adm Control Enabled F4 Key Selected Extr/Adm Control Active Modbus Command Selected Relays # 2 through # 6 are entered following the same rules as described for Relay # 1. Communications Block When this header appears in the display, press the down arrow key to configure this block or press a left or right arrow key to select another block to configure. USE COMMUNICATIONS? dflt= NO (Yes/No) Set to YES followed by ENTER to use the Modbus communications feature of the 505E. There are two identical Modbus ports available. Either or both can be configured for use. Select NO followed by ENTER if Modbus communications will not be used. USE MODBUS PORT 1? dflt= NO (Yes/No) Set to YES followed by ENTER to use the Modbus Port 1. Set to NO followed by ENTER to skip to ‘Use Modbus Port 2’. If the displayed value is already correct, simply select ENTER. ASCII OR RTU dflt= 2 (1, 2) Enter the integer corresponding to the Modbus transmission mode required followed by the ENTER key. Enter a ‘1’ for ASCII mode or a ‘2’ for RTU mode. For more information on the difference between these modes, refer to Chapter 6. If the displayed value is already correct, simply select ENTER. MODBUS DEVICE NUMBER dflt= 1 (1, 247) Enter the integer corresponding to the Modbus device number/address required followed by the ENTER key. If the displayed value is already correct, simply select ENTER. COMMUNICATIONS MODE dflt= 1 (1, 3) Enter the integer corresponding to the serial communications mode required followed by the ENTER key. Enter a ‘1’ for RS-232, a ‘2’ for RS-422 or a ‘3’ for RS-485 communications. If the displayed value is already correct, simply select ENTER. BAUD RATE dflt= 9 (1, 11) Enter the integer corresponding to the communications baud rate followed by the ENTER key. If the displayed value is already correct, simply select ENTER. 1 = 110 2 = 300 3 = 600 4 = 1200 5 = 1800 6 = 2400 7 = 4800 8 = 9600 9 = 19200 10 = 38400 11 = 57600 STOP BITS dflt= 1 (1, 3) Enter the integer corresponding to the stop bits required followed by the ENTER key. If the displayed value is already correct, simply select ENTER. Enter a ‘1’ for 1 stop bit, a ‘2’ for 1.5 stop bits or a ‘3’ for 2 stop bits. PARITY dflt= 1 (1, 3) Enter the integer corresponding to the parity required followed by the ENTER key. If the displayed value is already correct, simply select ENTER. Enter a ‘1’ for none, a ‘2’ for odd parity or a ‘3’ for even parity. USE MODBUS PORT 2? dflt= NO (Yes/No) Set to YES followed by ENTER to use the Modbus Port 2. If the displayed value is already correct, simply select ENTER. Modbus Port # 2 is entered following the same rules as described for Modbus Port # 1.

Product Tags: DCS control module , Industrial control equipment , PLC redundant module

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs