HONEYWELL 51306673-100 EPNI

HONEYWELL 51306673-100 EPNI photo-1
US$ 1060 - 2050 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
HONEYWELL
Place of Origin:
China
Model Number:
51306673-100 EPNI
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name HONEYWELL
Place of Origin China
Model Number 51306673-100 EPNI

Brand: HONEYWELL

Type:51306673-100 EPNI

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

RMT CASCADE MAX RATE (UNITS/SEC) dflt= 5.0 (0.01, 1000) Enter the maximum rate at which the remote input will move the cascade setpoint followed by the ENTER key. CASCADE UNITS OF MEASURE: (must choose from list) Scroll through the option list by using the Adjust Up/Down Arrows or by selecting the NO key until the option desired appears, then press the YES or ENTER keys to select the option/function. Options: psi kPa MW kW degF degC t/h k#/hr kg/cm² bar atm #/hr (none) Readouts When this header appears in the display, press the down arrow key to configure this block or press a left or right arrow key to select another block to configure. All six 4–20 mA analog readouts may be configured. The function that the readout uses must be programmed or an error message will occur. For example, to use the Cascade Setpoint readout, the ‘Use Cascade’ function must be programmed. ANALOG READOUT # 1 FUNCTION (must choose from list) Scroll through the option list by using the Adjust Up/Down Arrows or by selecting the NO key until the option desired appears, then press the YES or ENTER keys to select the option/function. ANALOG READOUT OPTIONS (Not Used) Actual Speed Rmt Cascade Setpt Speed Setpoint Auxiliary Input Remote Speed Setpt Auxiliary Setpoint Sync/Load Share Input Rmt Auxiliary Setpt Sync Input Speed/Load Demand KW Input Extr/Adm Demand Extr/Adm Input HP Valve Limiter Setpt Extr/Adm Setpt LP Valve Limiter Setpt Rmt Extr/Adm Setpt HP Valve Demand Cascade Input LP Valve Demand Cascade Setpoint First Stage Press Input READOUT 1–4 mA VALUE (UNITS) dflt= 0.0 (-20000, 20000) Set the value (in engineering units) that corresponds to 4 milliamps (mA) on the analog output followed by the ENTER key. If the value on the display is correct, just select the ENTER key which will advance you to the next question. READOUT 1–20 mA VALUE (UNITS) dflt= 100 (-20000, 20000) Set the value (in engineering units) that corresponds to 20 milliamps (mA) on the analog output followed by the ENTER key. If the value on the display is correct, just select the ENTER key which will advance you to the next question. (Must be greater than the ‘Readout 4 mA Value’ Setting) Readouts #2 through #6 are entered following the same rules as described for Readout #1.

Product Tags: DCS control module , Industrial control equipment , PLC redundant module

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs