HONEYWELL 51305072-300 CLCN-B

HONEYWELL 51305072-300 CLCN-B photo-1
US$ 1060 - 2050 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
HONEYWELL
Place of Origin:
China
Model Number:
51305072-300 CLCN-B
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name HONEYWELL
Place of Origin China
Model Number 51305072-300 CLCN-B

Brand: HONEYWELL

Type:51305072-300 CLCN-B

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

AUX DROOP (%) dflt= 0.0 (0.0, 100) Enter the droop percentage followed by the ENTER key. If required, typically set between 4-6% and not more than 10%. AUX PID PROPORTIONAL GAIN (%) dflt= 1.0 (0.0, 100) Enter the aux PID proportional gain value followed by ENTER. This value is used to set auxiliary control response. This value can be changed in the Run Mode while the turbine is operating. If unknown, a recommended starting value is 1%. AUX PID INTEGRAL GAIN dflt= 0.3 (0.001, 50) Enter the aux PID integral gain value, in repeats-per-second (rps), followed by ENTER. This value is used to set auxiliary control response. This value can be changed in the Run Mode while the turbine is operating. If unknown, a recommended starting value is 0.3 rps. AUX PID DERIVATIVE RATIO (%) dflt= 100 (0.01, 100) Enter the aux PID derivative ratio followed by ENTER. This value is used to set auxiliary control response. This value can be changed in the Service Mode while the turbine is operating. If unknown, a recommended starting value is 100%. TIEBRKR OPEN AUX DSBL ? dflt= YES (Yes/No) Select YES followed by ENTER if the auxiliary control will be disabled when the utility tie breaker opens. If NO is selected, then auxiliary control will not be disabled when the utility tie breaker is opened. GENBRKR OPEN AUX DSBL ? dflt= YES (Yes/No) Select YES followed by ENTER if the auxiliary control will be disabled when the generator breaker opens. If NO is selected, then auxiliary control will not be disabled when the generator breaker is opened. USE REMOTE AUX SETTING ? dflt= NO (Yes/No) Set to YES to allow the aux setpoint to be adjusted from an analog input. (Must program a ‘remote auxiliary setpoint’ analog input) REMOTE AUX MAX RATE (UNITS/SEC) dflt= 5.0 (0.1, 1000) Enter the maximum rate at which the remote input will move the aux setpoint followed by the ENTER key. AUXILIARY UNITS OF MEASURE: (must choose from list) Scroll through the option list by using the Adjust Up/Down Arrows or by selecting the NO key until the option desired appears, then press the YES or ENTER keys to select the option/function. Options: psi t/h kPa k#/hr MW #/hr kW kg/cm² degF bar degC atm (none) Cascade Control Block When this header appears in the display, press the down arrow key to configure this block or press a left or right arrow key to select another block to configure. USE CASCADE CONTROL? dflt= NO (Yes/No) Select YES followed by ENTER to configure the cascade control function. Select NO if the cascade function is not used. INVERT CASCADE INPUT? dflt= NO (Yes/No) Select YES followed by ENTER if the cascade control will be reverse acting. If NO is selected, the control will be forward acting. Typically this will be set to NO, the only time the input would be inverted is if the HP valve needs to open when the input exceeds the setpoint. An example where the invert would be YES is for turbine inlet pressure control.

Product Tags: DCS control module , Industrial control equipment , PLC redundant module

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs