Home > Electrical & Electronics > Power Transmission & Transformer > Transformer > 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101

5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101

5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 photo-1
US$ 1047 - 2267 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
ABB
Place of Origin:
China
Model Number:
5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name ABB
Place of Origin China
Model Number 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101

Brand:ABB

Type:5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101

Origin: the Swiss

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

Auxiliary Dynamics The Auxiliary PID control uses its own set of dynamic settings. These values are programmable and may be tuned at any time. Refer to the PID Dynamic Adjustments section in this manual. Generator Load Limiter/Control On generator applications, the Auxiliary PID may be programmed to use the ‘KW/UNIT LOAD’ input signal instead of the Auxiliary input signal for limiting or control. This is the same input signal (KW/Unit Load input) used by the Speed PID for kW droop. This configuration allows the Auxiliary PID to limit or control generator power. Program the ‘USE KW/UNIT LOAD INPUT’ to ‘YES’ if this configuration is desired. Auxiliary Droop When sharing control of a parameter with another external controller, the Auxiliary control amplifier can also receive a programmable DROOP feedback signal for control loop stability. This feedback signal is a percentage of the LSS bus (control valve position). By including this second parameter into the control loop, the Auxiliary PID becomes satisfied, and does not fight with the other external controller over the shared parameter. The Droop % fed back to the Auxiliary PID is equal to the following defaulted settings:

Invert Auxiliary Input Depending on the control action required, the Auxiliary PID’s input signal can be inverted. If a decrease in HP control valve position is required to increase the Auxiliary process signal, program the ‘INVERT AUX INPUT’ setting to ‘YES’. An example of this control action would be when the Auxiliary PID is configured to control turbine inlet steam pressure. To increase turbine inlet steam pressure, HP control valve position must be decreased. Auxiliary Setpoint The Auxiliary setpoint can be adjusted from the 505E keypad, external contacts, Modbus commands, or through a 4–20 mA analog input. A specific setting can also be directly entered from the 505E keypad or through Modbus commands. The Auxiliary setpoint range must be defined in the program mode. Program settings ‘Min Aux Setpoint’ and ‘Max Aux Setpoint’ define the range of the Auxiliary setpoint and control. When a raise or lower Auxiliary Setpoint command is issued, the setpoint moves at the programmed ‘Aux Setpt Rate’ setting. If a Auxiliary raise or lower command is selected for longer than three seconds, the Auxiliary setpoint will move at the fast rate which is three times the Auxiliary setpoint rate. The Auxiliary setpoint rate, fast rate delay, and fast rate can all be adjusted in the Service mode. The shortest length of time a setpoint will move for an accepted raise or lower command is 120 milliseconds (240 milliseconds for a Modbus command). If the Auxiliary setpoint rate is programmed for 10 psi/sec, the smallest increment it will move is 1.2 psi (2.4 psi for Modbus). A specific setpoint may also be directly entered from the 505E keypad or through Modbus communications. When this is performed, the setpoint will ramp at the ‘Aux Setpt Rate’ (as defaulted in Service mode).

Product Tags: Control processor , Robot module , DCS, PLC card

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs