Brand: ABB
Type:DSDO115A 3BSE018298R1
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
The Synchronizing or Sync/Ld Share inputs are disabled by pressing the front panel NO key from the respective Status screen, opening the respective function’s Enable/Disable contact (if programmed), or selecting the Sync Disable command from either Modbus communications link. The Synchronizing analog input is automatically disabled when the generator breaker closes, but can be reenabled with the generator breaker closed, to allow synchronization across a tie line breaker. The Sync/Load Share analog input is automatically disabled when the generator breaker opens. Table 5-10 lists the possible synchronizing/loadsharing control messages. MESSAGE 3 MEANING Disabled Function is in disabled mode Inhibited Function is inhibited and cannot be enabled Enabled Function is enabled but not in control of the Setpt In Control Function is in control of the actuator output Table 5-10. Control Messages The following synchronizing and loadsharing control indications are available through the Modbus links: Generator Breaker Status, Utility Tie Breaker Status, Frequency Control, Sync is Enabled, Sync or Loadshare is In Control, Sync or Loadshare is Inhibited, and the Sync/Loadshare Input Failed Alarm. In addition to these indications, Sync/Loadshare Input analog value is also available. Relay indications can be programmed to indicate Sync Enabled, Sync/Loadshare Enabled, Loadshare Control and Frequency Control status parameters. Unit Load (KW) Key Screens This key is active if the unit is programmed for a generator application or if a first stage pressure analog input is configured. Figure 5-14 shows the possible screens that may appear if the kW key is pressed. Only the screens related to the functions programmed will be displayed. If a first stage pressure analog input is configured, screen 4 will appear. When the unit is programmed for a generator application, only one of the first three screens will appear, depending on the mode of operation (governor valve position droop or KW/unit load input signal droop). Screen 1 or 2 is displayed when the unit is programmed with a KW/Unit Load analog input and the input is not failed. Screen 3 is displayed if no KW/Unit Load analog input is programmed or the input is failed. 
Send Inquiry to This Supplier
You May Also Like
-
TC512V1 3BSE018059R1US$ 1067 - 2058MOQ: 1 Piece
-
TK803V018US$ 1067 - 2058MOQ: 1 Piece
-
5SHX2645L0004 3BHL000389P0104US$ 1067 - 2058MOQ: 1 Piece
-
UNITROL 1020 UNS0119A-Z,V1 3BHE030579R0003US$ 1067 - 2058MOQ: 1 Piece
-
TP830 3BSE018114R1US$ 1070 - 2061MOQ: 1 Piece
-
5SHX1445H0001 3BHL000391P0101US$ 1070 - 2061MOQ: 1 Piece
-
3BHB003230R0101 5SXE05-0152US$ 1070 - 2061MOQ: 1 Piece
-
REF615C_C HCFFAEAGANB2BAN1XCUS$ 1070 - 2061MOQ: 1 Piece
-
SK827005 SK827100-ASUS$ 1070 - 2061MOQ: 1 Piece
-
AIM0006 2RCA021397A0001FUS$ 1074 - 2065MOQ: 1 Piece