Brand Name: | Alphasense | Place of Origin: | United Kingdom | Model Number: | CO-BX |
Usage: | Gas Sensor | Theory: | Other, Electrochemical Gas Sensor |
Product Description
CO-BX Carbon Monoxide Sensor CO Sensor Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.
CO-BX Carbon Monoxide Sensor size:
32mm diameter package, the best choice for fixed site applications
The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology. The ‘X’ sensors have low hydrogen sensitivity, as drop-in replacements for the standard ‘F’ sensors.
CO-BX Carbon Monoxide Sensor CO Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 400ppm CO | 70 to 130 |
Response time | t90 (s) from zero to 400ppm CO | <25 |
Zero current | ppm equivalent in zero air | <± 3 |
Resolution | RMS noise (ppm equivalent) | <0.5 |
Range | ppm limit of performance warranty | 2,000 |
Linearity | ppm CO error at full scale, linear at zero, 1000ppm CO | <± 20 |
Overgas limit | maximum ppm for stable response to gas pulse | 5,000 |
CO-BX Carbon Monoxide Sensor CO Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | <0.2 |
Sensitivity drift | % change/year in lab air, monthly test | <3 |
Operating life | months until 80% original signal (24 month warranted) | > 24 |
CO-BX Carbon Monoxide Sensor CO Sensor ENVIRONMENTAL | ||
Sensitivity @ -20℃ | % (output @ -20℃/output @ 20℃) @ 400ppm CO | 40 to 60 |
Sensitivity @ 0℃ | % (output @ 0℃/output @ 20℃) @ 400ppm CO | 65 to 85 |
Sensitivity @ 50℃ | % (output @ 50℃/output @ 20℃) @ 400ppm CO | 110 to 130 |
Zero @ -20℃ | ppm equivalent change from20℃ | <0 to 4 |
Zero @ 0℃ | ppm equivalent change from 20℃ | <0 to 3 |
Zero @ 50℃ | ppm equivalent change from 20℃ | <0 to -6 |
CO-BX Carbon Monoxide Sensor CO Sensor CROSS SENSITIVITY | ||
Filter capacity | ppm·hrs H2S | 160,000 |
Filter capacity | ppm·hrs NO2 | 120,000 |
Filter capacity | ppm·hrs NO | 120,000 |
Filter capacity | ppm·hrs SO2 | 160,000 |
H2S sensitivity | % measured gas @ 20ppm H2S | <0.1 |
NO2 sensitivity | % measured gas @ 10ppm NO2 | <1 |
Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <0.1 |
NO sensitivity | % measured gas @ 50ppm NO | <25 |
SO2 sensitivity | % measured gas @ 20ppm SO2 | <0.1 |
H2 sensitivity | % measured gas @ 400ppm H2 at 20℃ | <5 |
C2H4 sensitivity | % measured gas @ 400ppm C2H4 | <10 |
NH3 sensitivity | % measured gas @ 20ppm NH3 | <0.1 |
CO-BX Carbon Monoxide Sensor CO Sensor KEY SPECIFICATIONS | ||
Temperature range | ℃ | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months @ 3 to 20℃ (stored in sealed pot) | 6 |
Load resistor | Ω (recommended) | 10 to 47 |
Weight | g | <13 |
Matched Transmitter board for CO-BX CO Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20 mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
Contact Us
- Week technology ltd
- Contact nameCherry
- Phone86-0755-83289036-843
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South Shenzhen,Guangdong
- BJ-62-1A Stand-combustible Gas Detector
- PO2-2x Percent Oxygen Sensor (O2 sensor)
- EE893 Digital NDIR CO2 Sensor Module for OEM Applications
- NO-AE High Concentration Nitric Oxide Sensor (NO Sensor)
- HCL-A1 Hydrogen Chloride Sensor (HCL Sensor)
- CH-D3 Miniature Size Combustible Gas Pellistor
- BJ-93D Stand-combustible Gas Detector
- F2000TSM-CO2-S/L Carbon Dioxide (CO2) Gas Detector
- MF4000 Series Gas Flow Meters - MF4003/MF4008
- MF5600 Series Detachable Display Gas Flow Meters - MF5612/MF5619
- ETO-A1 Ethylene Oxide Sensor (ETO Sensor)
- SOH-A2 Sulfur Dioxide + Hydrogen Sulfide Sensor (SO2 + H2S Sensor)
- DSM501B Dust Sensor Module for Air Quality Monitor
- NO-B1 Nitric Oxide Sensor (NO Sensor)
- TC-BO3-3 Portable Combustible Gas Detector
- TOCON_BLUE4 GaP Blue Light Detector with Integrated Amplifier
- Y520-A 4-Electrode Conductivity Sensor
- AMT-pH PH Shallow Water Sensor with Integrated Electronic Device
- TSPC-30S1 Series ToughSonic 14 Ultrasonic Level & Distance Sensor
- MB1014 LV-ProxSonar-EZ1 High Performance Ultrasonic Rangefinder
- WQ101 Rugged Water Temperature Sensor
- IoLine-HPB IoLine High Performance pH Electrodes with Temperature Sensor
- TOCON_A4 UVA Photodetector with Integrated Amplifier
- SG01S-C18 UVC-only SiC Based UV Photodiode With Standard DVGW W294
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Cherry
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-