Sulfur Dioxide Sensor (SO2 Sensor) SpecificationSulfur Dioxide Sensor PERFORMANCE Sensitivity nA/ppm in 10ppm SO2 140 to 250 Response time t90 (s) from zero to 10ppm SO2 <15 Zero current ppm equivalent in zero air <± 0.2 Resolution rms noise (ppm equivalent) <0.2 Range ppm SO2 limit of performance warranty 20 Linearity ppm error at full scale, linear at zero and 10 ppm SO2 <±2 Overgas limit ppm maximum SO2 for stable response to gas pulse 50 Sulfur Dioxide Sensor LIFETIME Zero drift ppm equivalent change/year in lab air <0.5 Sensitivity drift % change/year in lab air, monthly test <6 Operating life months until 80% original signal (24 month warranted) 24 Sulfur Dioxide Sensor ENVIRONMENTAL Sensitivity @ -20°C % (output @ -20°C/output @ 20°C) @ 10ppm SO2 90 to 100 Sensitivity @ 50°C % (output @ 50°C/output @ 20°C) @ 10ppm SO2 80 to 100 Zero @ -20°C ppm equivalent change from 20°C -0.2 to 0.2 Zero @ 50°C ppm equivalent change from 20°C 0.2 to 0.8 Sulfur Dioxide Sensor CROSS SENSITIVITY Filter capacity ppm hours of Hydrogen Sulfide nd H2S sensitivity % measured gas @ 20ppm H2S <15 NO2 sensitivity % measured gas @ 10ppm NO2 <-150 Cl2 sensitivity % measured gas @ 10ppm Cl2 <-50 NO sensitivity % measured gas @ 50ppm NO <50 CO sensitivity % measured gas @ 400ppm CO <1 H2 sensitivity % measured gas @ 400ppm H2 @ 20°C <1 C2H4 sensitivity % measured gas @ 400ppm C2H4 <40 NH3 sensitivity % measured gas @ 20ppm NH3 <1 Sulfur Dioxide Sensor KEY SPECIFICATIONS Temperature range °C -30 to 50 Pressure range kPa 80 to 120 Humidity range %rh continuous (see note below) 15 to 90 Storage period months @ 3 to 20°C (stored in sealed pot) 6 Load resistor Ω (recommended) 10 to 47 Weight g <6
Hydrogen Sulfide Sensor (H2S Sensor) Specification
| Hydrogen Sulfide Sensor PERFORMANCE | ||
| Sensitivity | nA/ppm in 20ppm H2S | 450 to 900 |
| Response time | t90 (s) from zero to 20ppm H2S @ 20℃ | <25 |
| Zero current | ppm equivalent in zero air | ± 0.25 |
| Resolution | rms noise (ppm equivalent) | <0.1 |
| Range | ppm H2S limit of performance warranty | 100 |
| Linearity | ppm error at full scale, linear at zero and 20ppm H2S | <±5 |
| Overgas limit | maximum ppm H2S for stable response to gas pulse | 200 |
| Hydrogen Sulfide Sensor LIFETIME | ||
| Zero drift | ppm equivalent change/year in lab air | <0.1 |
| Sensitivity drift | % change/year in lab air, monthly test | <2 |
| Operating life | months until 80% original signal ( 24 month warranted) | 24 |
| Hydrogen Sulfide Sensor ENVIRONMENTAL | ||
| Sensitivity @ -20°C | % (output @ -20°C/output @ 20°C) @ 20ppm H2S | 75 to 90 |
| Sensitivity @ 50°C | % (output @ 50°C /output @ 20°C) @ 20ppm H2S | 100 to 110 |
| Zero @ -20°C | ppm equivalent change from 20°C | ±0.2 |
| Zero @ 50°C | ppm equivalent change from 20°C | ±0.2 |
| Hydrogen Sulfide Sensor CROSS SENSITIVITY | ||
| Filter capacity | ppm.hrs of SO2 | nd |
| NO2 sensitivity | % measured gas @ 10ppm NO2 | <-25 |
| Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <-20 |
| NO sensitivity | % measured gas @ 50ppm NO | <15 |
| SO2 sensitivity | % measured gas @ 10ppm SO2 | <30 |
| CO sensitivity | % measured gas @ 400ppm CO | <1.5 |
| H2 sensitivity | % measured gas @ 400ppm H2 | <0.2 |
| C2H4 sensitivity | % measured gas @ 400ppm C2H4 | <0.2 |
| NH3 sensitivity | % measured gas @ 20ppm NH3 | <±0.5 |
Send Inquiry to This Supplier
You May Also Like
-
RESP_IRR_20 C 15x15 Respiratory Irritant Sensor 20 Ppm C Package 110-902US$ 30 - 50MOQ: 1 Piece
-
MTCS2601 Thermal Conductivity Sensor for Leak or Pressure DetectionUS$ 0.01 - 0.1MOQ: 1 Piece
-
NO2-B1 Nitrogen Dioxide Sensor (NO2 Sensor)US$ 50 - 80MOQ: 1 Piece
-
NO-A4 Nitric Oxide Sensor (NO Sensor) 4-ElectrodeUS$ 70 - 100MOQ: 1 Piece
-
CL2-B1 Chlorine Sensor (CL2 Sensor)US$ 0.001 - 0.01MOQ: 1 Piece
-
SO2-BE High Concentration Sulfur Dioxide Sensor (SO2 Sensor)US$ 40 - 80MOQ: 1 Piece
-
H2S-BE High Concentration Hydrogen Sulfide Sensor (H2S Sensor)US$ 50 - 70MOQ: 1 Piece
-
SO2-BF Sulfur Dioxide Sensor SO2 SensorUS$ 30 - 80MOQ: 1 Piece
-
DL0001 Laser Dust SensorUS$ 0.001 - 0.01MOQ: 1 Piece
-
H2-AF Hydrogen Sensor (H2 Sensor)US$ 30 - 70MOQ: 1 Piece