Home > Electrical & Electronics > Sensor > Pressure Sensor > ETO-A1 Ethylene Oxide Sensor (ETO Sensor)

ETO-A1 Ethylene Oxide Sensor (ETO Sensor)

ETO-A1 Ethylene Oxide Sensor (ETO Sensor) photo-1
US$ 40 - 120 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
Alphasense
Place of Origin:
United Kingdom
Model Number:
ETO-A1
Payment & Shipping
Payment Methods:
Port of Shipment:
HK
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Alphasense
Place of Origin United Kingdom
Model Number ETO-A1
Usage Gas Sensor
Theory Other, Electrochemical Gas Sensor
Output Analog Sensor

ETO-A1 Ethylene Oxide Sensor ETO Sensor Description
Alphasense is expanding its line of Electrochemical 
Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.

Ethylene Oxide (C2H4O)
The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application.
See application note AAN113.
Available in A and B series

ETO-A1 Ethylene Oxide Sensor ETO Sensor Schematic Diagram


ETO-A1 Ethylene Oxide Sensor ETO Sensor PERFORMANCE
Sensitivity
nA/ppm in 20ppm EtO
2000 to 3200
Response time
t90 (s) from zero to 20ppm EtO
<150
Zero current
ppm equivalent in zero air
± 0.6
Resolution
RMS noise (ppm equivalent)
<0.1
Range
ppm EtO limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero, 40ppm EtO
5 to 10
Overgas limit
maximum ppm for stable response to gas pulse
200



ETO-A1 Ethylene Oxide Sensor ETO Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/month in lab air, twice monthly test
nd
Operating life
months until 80% original signal (12 month warranted)
> 24



ETO-A1 Ethylene Oxide Sensor ETO Sensor ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 40ppm EtO
35 to 65
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 40ppm EtO
110 to 140
Zero @ -20°C
ppm equivalent change from 20°C
<± 0.5
Zero @ 50°C
ppm equivalent change from 20°C
<2 to 4



ETO-A1 Ethylene Oxide Sensor ETO Sensor CROSS SENSITVITY
H2S  sensitivity
% measured gas @ 20ppm H2S
<200
NO2  sensitivity
% measured gas @ 10ppm NO2
< 50
Cl2    sensitivity
% measured gas @ 10ppm Cl2
<-1
NO    sensitivity
% measured gas @ 50ppm NO
<80
SO2  sensitivity
% measured gas @ 20ppm SO2
<50
CO    sensitivity
% measured gas @ 400ppm CO
<30
H2     sensitivity
% measured gas @ 400ppm H2
<0.5
C2H4 sensitivity
% measured gas @ 80ppm C2H4
<100
NH3   sensitivity
% measured gas @ 25ppm NH3
<0.1
HCHO sensitivity
% measured gas @ 4ppm HCHO
90
CO2    sensitivity
% measured gas @ 5% CO2
<0.1



ETO-A1 Ethylene Oxide Sensor ETO Sensor KEY SPECIFICATIONS
Temperature range
°C 
-30 to 50
Pressure range
kPa 
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in original container)
6
Load resistor
Ω (recommended)
10 to 47
Bias voltage
mV (working electrode potential above reference electrode potential)
300
Weight
g
<6



Matched Transmitter board for ETO-A1 ETO Sensor

4-20mA Digital Transmitter Board
   • Factory calibration, custom-set for immediate use
   • Digital zero, sensitivity and temperature compensation
   • Digital and 4-20mA output
   • Biased or unbiased operation
   • Calibration and range change


Product Tags: Ethylene Oxide Sensor , ETO Sensor

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Distributor/Wholesaler
Year Established
2014
Overseas Office
Yes
Total Employees
101 - 200 People

Recommended Categories

Explore top categories and find suppliers for your specific needs