Home > Electrical & Electronics > Sensor > Pressure Sensor > HCN-A1 Hydrogen Cyanide Sensor (HCN Sensor)

HCN-A1 Hydrogen Cyanide Sensor (HCN Sensor)

HCN-A1 Hydrogen Cyanide Sensor (HCN Sensor) photo-1
US$ 50 - 100 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
Alphasense
Place of Origin:
United Kingdom
Model Number:
HCN-A1
Payment & Shipping
Payment Methods:
Port of Shipment:
HK
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Alphasense
Place of Origin United Kingdom
Model Number HCN-A1
Usage Gas Sensor
Theory Other, Electrochemical Gas Sensor
Output Analog Sensor

HCN-A1 Hydrogen Cyanide Sensor HCN Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.

Hydrogen Cyanide (HCN)
In manufacturing, the use of Styrene Acrylonitrile for food packaging and other consumer products has increased the danger of HCN generated during fires. Alphasense has responded to this issue with HCN sensors with fast response and stable output.
Available in A, B and D series.


HCN-A1 Hydrogen Cyanide Sensor HCN Sensor Schematic Diagram



HCN-A1 Hydrogen Cyanide Sensor HCN Sensor PERFORMANCE
Sensitivity
nA/ppm in 30ppm HCN
55 to 85
Response time
t90 (s) from zero to 30ppm HCN
Zero current
ppm equivalent in zero air
Resolution
RMS noise (ppm equivalent)
Range
ppm HCN limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero, 40ppm HCN
4 to 8
Overgas limit maximum ppm for stable response to gas pulse
150



HCN-A1 Hydrogen Cyanide Sensor HCN Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/year in lab air, monthly test
nd
Operating life
months until 80% original signal (12 month warranted)
> 12



HCN-A1 Hydrogen Cyanide Sensor HCN Sensor ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 30ppm HCN
75 to 95
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 30ppm HCN
105 to 120
Zero @ -20°C ppm equivalent change from 20°C
Zero @ 50°C
ppm equivalent change from 20°C



HCN-A1 Hydrogen Cyanide Sensor HCN Sensor CROSS SENSITIVITY
H2S  sensitivity
% measured gas @ 20ppm H2S
NO2  sensitivity
% measured gas @ 10ppm NO2
Cl2    sensitivity
% measured gas @ 10ppm Cl2
NO    sensitivity
% measured gas @ 50ppm NO
SO2  sensitivity
% measured gas @ 20ppm SO2
CO    sensitivity
% measured gas @ 400ppm CO
H2    sensitivity
% measured gas @ 400ppm H2
C2H4 sensitivity
% measured gas @ 80ppm C2H4
NH3  sensitivity
% measured gas @ 20ppm NH3
CO2  sensitivity
% measured gas @ 5% volume CO2



HCN-A1 Hydrogen Cyanide Sensor HCN Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to 50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in original container)
6
Load resistor
Ω (recommended)
10 to 33
Bias voltage
mV
not required
Weight
g



Matched Transmitter board for HCN-A1 HCN Sensor

4-20mA Digital Transmitter Board
   • Factory calibration, custom-set for immediate use
   • Digital zero, sensitivity and temperature compensation
   • Digital and 4-20mA output
   • Biased or unbiased operation
   • Calibration and range change


Product Tags: Hydrogen Cyanide Sensor , HCN Sensor

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Distributor/Wholesaler
Year Established
2014
Overseas Office
Yes
Total Employees
101 - 200 People