Brand Name | Sglux | Place of Origin | Germany | |
Model Number | TOCON_C2 | Usage | Other, UV Photodetector | |
Theory | Optical Sensor | Output | Analog Sensor |
Product Description
TOCON_C2
UVC-only SiC based UV photodetector with integrated amplifier
◆ TOCON_C2 UV Photodetector General Features
Properties of the TOCON_C2 UV Photodetector
• UVC-only SiC based UV photodetector in TO5 housing with concentrator lens cap
• 0 … 5 V voltage output
• peak wavelength at 275 nm
• max. radiation (saturation limit) at 254 nm is 180 nW/cm2, minimum radiation (resolution limit) is 18 pW/cm2
• Applications: low UVC radiation detection, occupational safety
What is a TOCON?
A TOCON is a 5 Volt powered UV photodetector with integrated amplifier converting UV radiation into a 0 … 5V volt-age output. The V out pin of the TOCON can be directly connected to a controller, a voltmeter or any other data analyz-ing device with voltage input. Highly modern electronic components and a hermetically sealed metal housing with UV glass window eliminates noise caused by parasitic resistance paths inside the package or EMI. A TOCON is a per-fect solution for each industrial UV sensing application starting from flame detection at pW/cm2 level up to UV curing lamp control at W/cm2 level. This thirteen orders of magnitude range is covered by ten different TOCONs that differ by their sensitivity. The TOCONs are produced as UV broadband sensors or with filters for selective measurement.
Silicon Carbide (SiC) detector chip inside
Sophisticated electronics make a TOCON a reliable component in harsh environments as well as for extremely low or extremely high UV radiation. But what makes the TOCON a quasi eternally living sensor is the sglux in-house pro-duced SiC detector chip featured by a PTB-reported extreme radiation hardness.
◆ TOCON_C2 UV Photodetector Specifications
Parameter | Symbol | Value | Unit |
Spectral Characteristics | |||
Typical Responsivity at Wavelength 254 nm | Smax | 28 | mV/nW/cm2 |
Wavelength of max. Spectral Responsivity | λmax | 275 | nm |
Responsivity Range (S=0.1*Smax) | – | 225 … 287 | nm |
Visible Blindness (Smax/S>405nm) | VB | > 1010 | – |
General Characteristics (T=25°C, Vsupply=+5 V) | |||
Supply Voltage | VSupply | 2.5 … 5 | V |
Saturation Voltage | VSat | VSupply - 5% | V |
Dark Offset Voltage | VOffset | 50 | µV |
Temperature Coefficient at Peak | Tc | < -0.3 | %/K |
Current Consumption | I | 150 | µA |
Bandwidth (-3 dB) | B | 15 | Hz |
Risetime (10-90%) | trise | 0.075 | s |
(other risetimes on request) | |||
Maximum Ratings | |||
Operating Temperature | Topt | -25 … +85 | °C |
Storage Temperature | Tstor | -40 … +100 | °C |
Soldering Temperature (3s) | Tsold | 300 | °C |
Contact Us
- Shenzhen Isweek Ltd.
- Contact nameMs Rita yu Chat Now
- Phone86-755-83289036
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan, Shenzhen, Guangdong
Product Categories
New Products
-
MICROceL CF Carbon Monoxide (CO) Gas Sensor
-
GM816 Digital Anemometer
-
U30-REMOTE Series ToughSonic REMOTE 30 Ultrasonic Water Level Sensor
-
LVL-300 Series ToughSonic CHEM 20 Ultrasonic Level Sensor
-
MB7139 XL-TrashSonar-WR High Performance Ultrasonic Trash Bin Measurement
-
MICROceL HS Hydrogen Sulfide (H2S) Gas Sensor
-
4HS+ CiTiceL Hydrogen Sulfide (H2S) Gas Sensor
-
4ND CiTiceL Nitrogen Dioxide (NO2) Gas Sensor
-
ULPSM-O3 968-046 Ultra-Low Power Analog Ozone (O3) Sensor Module
-
TOCON_C1 UVC Photodetector with Integrated Amplifier
-
TSPC-30S1 Series ToughSonic 14 Ultrasonic Level & Distance Sensor
-
LVL-100 Series ToughSonic CHEM 10 Ultrasonic Level Sensor
-
MB7040 I2CXL-MaxSonar-WR High Performance Ultrasonic Rangefinder
-
NH3-3E100SE Ammonia Sensor (NH3 Sensor)
-
ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor
-
GUVB-T21GH UV Sensor Module
-
OPC-N3 PM2.5 Particle Sensor
-
HCL-A1 Hydrogen Chloride (HCN) Sensor
-
MB7137 I2CXL-TrashSonar-WR High Performance Ultrasonic Sensor for Trash Bin Measurement
-
MB7066 XL-MaxSonar-WRL1 High Performance Ultrasonic Rangefinder
-
CS8000TC Cooling Tower Conductivity Sensor and Flow Cell
-
IS200CD/IS222CD Series Epoxy Body Combination ISE Electrodes
-
SE 554 Memosens pH Sensor
-
DO1200 Laboratory Dissolved Oxygen Sensor
Popular Searches
Recommended Products
- SMD 2835 3528 1206 0603 0805 Light sensor, phototransistor, photodiode, photo sensor, 520nm 550nm 560nm 850nm 940nm CDS replacement
- SMD 2835 3528 1206 0603 0805 Light sensor, phototransistor, photodiode, photo sensor, 520nm 550nm 560nm 850nm 940nm CDS replacement
- 5mm DIP Light sensor, phototransistor, photodiode, photo sensor, 520nm 550nm 560nm 850nm 940nm CDS replacement
- 5mm DIP Light sensor, phototransistor, photodiode, photo sensor CDS replacement, 520nm 550nm 560nm 850nm 940nm CDS replacement
- 5mm DIP Light sensor, phototransistor, photodiode, photo sensor, 520nm 550nm 560nm 850nm 940nm CDS replacement
- 5mm DIP Light sensor, phototransistor, photodiode, photo sensor CDS replacement, 520nm 550nm 560nm 850nm 940nm
- KNE Japan IKO high-precision cross roller linear guide CRW6-300
- KNE Japan IKO high-precision cross roller linear guide CRW2-180
- KNE Japan IKO high-precision cross roller linear guide CRW2-135
- KNE Japan IKO high-precision cross roller linear guide CRW2-105
- Omron Rotary Encoder E6B2-CWZ6C 1000P/R
- IFM ID5055, Inductive Sensor, 50 mm Range, Flush Mount, PNP.NO, 10-36 VDC, ID Series
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ms Rita yu
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile