Home > Products > Water Quality Sensors > DO1200 Laboratory Dissolved Oxygen Sensor
DO1200 Laboratory Dissolved Oxygen Sensor
- 3000 Piece / Pieces per Month
- HK
- T/T PayPal
- 7 days
- CS650/CS675/CS676 Series Industrial Contacting Conductivity Sensors
- CS150/CS200 Series Low Cost Epoxy Body Conductivity Sensors
- GUVC-T21GH UV Sensor Module
- SG01L-C5 UVC-only SiC Based UV Photodiode With Standard DVGW W294
- MS5536C SMD Gage Pressure sensor Module
- CH-D3 Miniature Size Combustible Gas Pellistor
Product Details
Brand Name: | Sensorex | Place of Origin: | United States | Model Number: | DO1200 |
Usage: | Other, Dissolved Oxygen Sensor |
Product Description
DO1200 and DO1200TC Dissolved Oxygen Sensors
Item No.: DO1200/H, DO1200/T, DO1200TC/H, DO1200TC/T, 971598, 971598TC
DO1200 Dissolved Oxygen Sensor Features
• Reliable galvanic sensing technology
• Compact 12mm design
• For portable, laboratory or on-line use
• Optional integral ATC element
• Easy to use pre-membraned replacement caps
DO1200 Dissolved Oxygen Sensor Description
The DO1200 and DO1200TC feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding HDPE membrane caps for portable or lab use. Optional PTFE membrane caps are available for on-line or heavy UV exposure applications. Fill solution is replaceable when required.
The DO1200 is supplied without internal temperature compensation. The DO1200TC can be supplied with a variety of user defined ATC elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our FC75P 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch FNPT threaded tees.
DO1200 Dissolved Oxygen Sensor Specifications
Range | 0-20 mg/L |
Body Material | Epoxy and Noryl |
Max Temperature | 50 Degrees C |
Saturation Output | HDPE = 47mV +/- 9mV, PTFE = 33mV+/-9mV |
Pressure | 0-100 psig (7.5 Bar) |
Calibration | Single point in air |
Response Time | After Equilibration, HDPE 1 minute for 2mV, PTFE 2 minutes for 2mV |
Dependable galvanic technology requires no warm up and is ready for use. Probes can be ordered in required cable lengths and appropriate connectors.
DO1200 Dissolved Oxygen Sensor Ordering Information
DO1200 and DO1200TC Oxygen cells are supplied standard with a 30 inch (76 cm) cable and tinned leads. Special cable lengths and connectors may be specified at an additional charge. For in-line mounting, you must order 971598 or 971598TC (fitting is pre-installed at factory)
Model | |
DO1200/H | Galvanic DO Sensor, HDPE membrane |
DO1200TC/H | Galvanic DO Sensor HDPE membrane with ATC - Specify Required ATC Element |
DO1200/T | Galvanic DO Sensor, PTFE membrane |
DO1200TC/T | Galvanic DO Sensor, PTFE membrane with ATC - Specify Required ATC Element |
971598 | DO1200/H with pre-installed 3/4" NPT male fitting |
971598TC | DO1200TC/H with pre-installed 3/4" NPT male fitting |
Accessories | |
DO1200-KIT/H | DO1200 maintenance kit. Includes 1 each premembraned cap (HDPE), 1 each 30mL bottle of filling solution, 1 each 10mL syringe with needle. |
DO1200-CAP/H | Replacement membrane cap, with preinstalled HDPE membrane. |
DO1200-Cap/T | Replacement membrane cap, with preinstalled PTFE membrane. |
DO1200-KIT/T | DO1200 maintenance kit. Includes 1 each premembraned cap (PTFE), 1 each 30mL bottle of filling solution, 1each 10mL syringe with needle. |
DO1202 | Electrolyte for DO1200, 1 each 4oz. bottle |
Contact Us
- Shenzhen Isweek Ltd.
- Contact nameMs Rita yu
- Phone86-755-83289036
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong
- Y504-A Online Optical Dissolved Oxygen Sensor
- Y511-A Online Self-cleaning Turbidity Sensor
- EDT-01 Electronic Diffusion Tube for Air Quality Monitor
- DGS-NO2 968-043 Digital Nitrogen Dioxide (NO2) Gas Sensor Module
- COH-A2 Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor)
- 4OXV CiTiceL Oxygen (O2) Gas Sensor
- ULPSM-CO 968-001 Ultra-Low Power Analog Carbon Monoxide Sensor Module
- Clean CAP Plus Wireless Ultrasonic Fill-Level Sensor
- MB1040 LV-MaxSonar-EZ4 High Performance Ultrasonic Rangefinder
- SG200C/SG300C Series Plastic and Glass pH and Reference Electrodes
- TS418-1N426 Thermopile Infrared Sensor for NDIR CO2 Gas Detection
- WQ-FDO Highly Accurate and Stable Optical Dissolved Oxygen Sensor
- WQ-COND Rugged Water Conductivity Sensor
- CM1106 Single Beam Infrared Carbon Dioxide Sensor NDIR CO2 Sensor Module
- Y520-A 4-Electrode Conductivity Sensor
- HG-C40U Ultrasonic Range Finder Sensor & Module (UART) (Conventional)
- HG-M40/HG-L40 Series Ultrasonic Sensor Module for a Robot
- A1-7C3T/A1-8C3T PbS 2 Watt Cooled Photoconductive IR Detectors
- PbSe 4 Channel Infrared Detector
- HG-MP40WP Ultrasonic Multi-Step Proximity Sensor/Module
- HG-LB40C-5V-DM Distance Measurement Ultrasonic Sensor Interface Boards
- AR5750B Refrigerant/SF6 Gas Leak Detector
- AR8200 Carbon Dioxide Detector CO2 Detector
- VST-C598IH AC/ DC Operated Carbon Monoxide Alarm (CO Alarm)
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ms Rita yu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-