RHH/RHW-2/USE-2 ALUMINUM CONDUCTOR

RHH/RHW-2/USE-2 ALUMINUM CONDUCTOR photo-1

Product Spotlights

Cross-Linked Polyethylene Insulated 6 - 1000 MCM • 600V • 90°C Dry and Wet • Direct Burial
Negotiable MOQ: 3000 Meters (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Certification:
ISO9001
Application:
Overhead
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai
Delivery Detail:
7 days
Certification ISO9001
Application Overhead

Application
Type RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the National Electrical Code. When used as Type USE-2, conductors are suitable for use as underground service entrance conductors for direct burial at conductor temperatures not to exceed 90°C. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHW-2 or RHH or USE-2 conductors is 600 volts.

Construction
Type RHH or RHW-2 or USE-2 conductors are AA-8000 series aluminum alloy, compact stranded. The insulation is an abrasion, moisture, heat and sunlight-resistant black cross-linked polyethylene (XLP). CT rated available upon request sizes 1/0 and larger.

Features
● Conductor for reduced diameter
● General purpose use in construction:
● Residential
● Commercial
● Institutional
● Industrial construction

Standards & References
Type RHH or RHW-2 or USE-2 conductors comply with the following:
● ASTM B-800 and B-801
● UL 44 for RHH or RHW-2
● UL 854 for USE-2
● National Electrical Code, NFPA 70, 2011 Edition
● NEMA WC-70 Construction Requirements
● RoHS/Reach Compliant

 

High reliability

Super high pressure

Less maintenance

Technical Parameter

RHH/RHW-2/USE-2 Aluminium Conductor


Conductor Insulation thickness Nominal O.D. Approx. weight Ampacity+
AWG/kcmil Min. No. mm mils mm kg/km 60℃ 75℃ 90℃
6 7 1.52 60 7.3 67 40 50 60
4 7 1.52 60 8.5 95 55 65 75
2 7 1.52 60 9.9 136 75 90 100
1 18 2.03 80 11.7 185 85 100 115
1/0 18 2.03 80 12.6 222 100 120 135
2/0 18 2.03 80 13.6 267 115 135 150
3/0 18 2.03 80 14.8 324 130 155 175
4/0 18 2.03 80 16.1 394 150 180 205
250 35 2.41 95 18.0 480 170 205 230
300 35 2.41 95 19.3 560 190 230 255
350 35 2.41 95 20.5 639 210 250 280
400 35 2.41 95 21.6 719 225 270 305
500 35 2.41 95 23.5 874 260 310 350
600 58 2.79 110 26.2 1065 285 340 385
700 58 2.79 110 27.9 1221 310 375 420
750 58 2.79 110 28.6 1297 320 385 435
900 58 2.79 110 31.0 1529 355 425 480
1000 58 2.79 110 32.5 1685 375 445 500


+Allowable ampacities shown are for general use as specified by the 2014 Edition of the National Electrical Code Sections 310.15 and 240.4(D)

Unless the equipment is marked for use at higher temperatures the conductor shall be limited to the following per NEC 110.14(C):
75℃ - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
90℃ - THHN dry locations and THWN-2 wet or dry locations for ampacity adjustment purposes using NEC section 310.15.


Product Tags: RHH/RHW-2 Aluminum Cable , 600V Direct Burial Wire , 90°C XLPE Building Wire

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2009
Factory Size
50,000-100,000 square meters
Annual Export Value