Twophase 380v Parallel Constant Power Heating Cable Single Phase Constant Wattage Heat Trace Cable for Oil and Gas
Constant Wattage Heating Cable is ideally suited for applications where a particular watt density is required at all times.They
are flexible and can be cut-to-length in the field.Although not suited for
overlapping,its constant output makes it an ideal choice for higher temperature applications where higher
watt densities are reauiredConstant-wattae heatina cable provides precise and constant temperatures
up to 260cldeal for a wide ranae of applications. our heatina cables ensure power remains constant
reaardless of temperature! Constant Wattaae heating cables are suitable for use in harsh corrosive and
hazardous area applications
Technical Data Sheet of Two-core Parallel Type Constant Wattage Heating Cable (220V) |
||||||||||
Two-core Parallel Type |
Rated
Voltage
(V)
|
Rated
Power
(w/m)
|
Max Application
Length(m)
|
Max Maintain Temperatue of Fluid (℃) |
Max Tolerance Temperature(℃) |
|||||
RDY2Q-J3-10 |
220 |
10 |
200 |
50 |
205 |
|||||
RDY2Q-J3-20 |
220 |
20 |
120 |
140 |
205 |
|||||
RDY2Q-J3-30 |
220 |
30 |
100 |
125 |
205 |
|||||
RDY2Q-J3-40 |
220 |
40 |
100 |
100 |
205 |
|||||
Technical Data Sheet of Two-core Parallel Type Constant Wattage Heating Cable (380V) |
||||||||||
Two-core Parallel Type |
Rated
Voltage (V) |
Rated
Power
(w/m)
|
Max Application
Length(m)
|
Max Maintain Temperatue of Fluid (℃) |
Max Tolerance Temperature(℃) |
|||||
RDY2Q-J3-20-380 |
380 |
20 |
300 |
130 |
205 |
|||||
RDY2Q-J3-30-380 |
380 |
30 |
230 |
125 |
205 |
|||||
RDY2Q-J3-40-380 |
380 |
40 |
185 |
100 |
205 |
|||||
Technical Data Sheet of Three-core Parallel Type Constant Wattage Heating Cable (380V) |
||||||||||
Three-core Parallel Type |
Rated
Voltage (V) |
Rated Power (w/m) |
Max Application
Length(m)
|
Max Maintain Temperatue of Fluid (℃) |
Max Tolerance Temperature(℃) |
|||||
RDY3Q-J3-20 |
380 |
20 |
390 |
150 |
205 |
|||||
RDY3Q-J3-30 |
380 |
30 |
320 |
140 |
205 |
|||||
RDY3Q-J3-40 |
380 |
40 |
300 |
130 |
205 |
|||||
RDY3Q-J3-50 |
380 |
50 |
250 |
120 |
205 |
|||||
Technical Data Sheet of Two-core Parallel Type Constant Wattage Heating Cable (220/380V) |
||||||||||
Two-core Parallel Type |
Rated
Voltage (V) |
Rated Power (w/m) |
Max Application
Length(m)
|
Max Maintain Temperatue of Fluid (℃) |
Max Tolerance Temperature(℃) |
|||||
RDY2Q-J4-40 |
220/380 |
40 |
120 |
200 |
260 |
|||||
RDY2Q-J4-50 |
220/380 |
50 |
110 |
180 |
260 |
|||||
RDY2Q-J4-60 |
220/380 |
60 |
100 |
160 |
260 |
|||||
And the MOQ for customized product is 10pcs
which will save energy and make temperature control simpler and more accurate.
Send Inquiry to This Supplier
You May Also Like
-
Constant Wattage Heating Cable Price China Constant Temperature Heating Cable for Underground Heating CableUS$ 2.5 - 3.5MOQ: 10 Meters
-
Copper Conductor Heating Cable XLPE FEP Insulated Heating Tracing Cable for Pipe Insulation Constant Temperature PlugUS$ 2 - 5MOQ: 10 Meters
-
Constant Wattage Heating Cable Twin Conductor Water Pipe Electric Heated Floor CableUS$ 2 - 5MOQ: 10 Meters
-
High Temperature 150 Degree Pipelines Heating Cable With Copper Conductor & FEP Insulation Constant Wattage Heat CableUS$ 2 - 3.5MOQ: 1 Meter
-
Two-Core RED Plastic Drum Underground Electric Heating Cable Constant-Wattage Underfloor Pipe Heating CableUS$ 2 - 4MOQ: 1 Meter
-
Constant Wattage Electric Heating Cable Constant Heat Cable Constant Heating TapeUS$ 1.5 - 5MOQ: 10 Meters
-
Twin Conductor Electric Parallel Constant Power Heating Cable for Freeze ProtectionUS$ 1.5 - 5MOQ: 10 Meters
-
105 Degree Constant Wattage Heating Cables Heat Resistance CableUS$ 1.5 - 5MOQ: 10 Meters
-
High-Temperature Constant Temperature Heating Cable for Hot PipesUS$ 1.5 - 5MOQ: 10 Meters
-
220v Two Core Parallel Constant Wattage Heating Cable Electric Heating CableUS$ 1.5 - 5MOQ: 10 Meters