Home > Instruments & Meters > Electronic Instrument > Calibrator > Medical Cleaning Machine Sterilizer Calibration Device

Medical Cleaning Machine Sterilizer Calibration Device

Medical Cleaning Machine Sterilizer Calibration Device photo-1
Negotiable MOQ: 1 Combo (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Business Type:
Manufacturer
Year Established:
2006
Factory Size:
1,000-3,000 square meters
Payment & Shipping
Payment Methods:
Port of Shipment:
SHANGHAI
Delivery Detail:
20 days
Medical cleaning machine sterilizer calibration device

Product Introduction

washer-disinfector is mainly used for cleaning and disinfecting the reusable medical equipment and the items in the fields of medical institutions and biopharmaceuticals. Automatic washer disinfector is
By automatically controlling the water flow, water pressure, water temperature, detergent dose and other parameters in the cabin, the items are maintained at the required temperature for a certain period of time to achieve cleaning and disinfection.
Purpose. Disinfection supply center (CSSD) application of cleaning and disinfection equipment is an important part of the whole hospital cleaning system, safe and effective is the key to cleaning and disinfection.
The cleaning and disinfecting machine measurement and calibration device independently developed by Chuan Yue (Shanghai) Electronic Technology Co., Ltd. adopts high-precision sensors and calibration technology to ensure the safety of medical cleaning and disinfecting machines.
The parameters (such as temperature, pressure, time, etc.) are accurately measured and calibrated, in line with the JJFxxxx-20xx "Cleaning Disinfector Calibration Specification", JJF (Jin) 06-2020 Cleaning Disinfector
The requirements of the temperature parameter calibration specification meet the requirements of the measurement calibration institution, the hospital disinfection supply center, and the instrument manufacturer for the test and calibration of the temperature of the medical cleaning machine.

 

Product Features

  • Support the calibration of multi-brand and multi-model medical cleaning and disinfecting machines

  • software is simple and convenient to operate, effectively improving calibration efficiency and accuracy

  • data wireless real-time transmission, support export, support offline storage

  • Using high-quality materials and advanced manufacturing technology to ensure stability and reliability

Product Specifications

Product ModelCY-MCD
Temperature measurement range(0-100)℃
Temperature Resolution0.01 ℃
temperature accuracy± 0.2 ℃
time resolutionbetter than 1s
Time Accuracy±1s/h
Start ModeTiming/Delay/Manual
sampling interval1s ~ 24 hours
Data Storage≥ 100000 group
protection levelIP68
Material316L Stainless Steel Peek
transmission modewireless real-time
Power supply modebattery; replaceable

 

Adapted instrument

Medical cleaning machine sterilizer calibration device Product Introduction washer-disinfector is mainly used for cleaning and disinfecting the reusable medical equipment and the items in the fields of medical institutions and biopharmaceuticals. Automatic washer disinfector is By automatically controlling the water flow, water pressure, water temperature, detergent dose and other parameters in the cabin, the items are maintained at the required temperature for a certain period of time to achieve cleaning and disinfection. Purpose. Disinfection supply center (CSSD) application of cleaning and disinfection equipment is an important part of the whole hospital cleaning system, safe and effective is the key to cleaning and disinfection. The cleaning and disinfecting machine measurement and calibration device independently developed by Chuan Yue (Shanghai) Electronic Technology Co., Ltd. adopts high-precision sensors and calibration technology to ensure the safety of medical cleaning and disinfecting machines. The parameters (such as temperature, pressure, time, etc.) are accurately measured and calibrated, in line with the JJFxxxx-20xx "Cleaning Disinfector Calibration Specification", JJF (Jin) 06-2020 Cleaning Disinfector The requirements of the temperature parameter calibration specification meet the requirements of the measurement calibration institution, the hospital disinfection supply center, and the instrument manufacturer for the test and calibration of the temperature of the medical cleaning machine.   Product Features Support the calibration of multi-brand and multi-model medical cleaning and disinfecting machines software is simple and convenient to operate, effectively improving calibration efficiency and accuracy data wireless real-time transmission, support export, support offline storage Using high-quality materials and advanced manufacturing technology to ensure stability and reliability Product Specifications Product Model CY-MCD Temperature measurement range (0-100)℃ Temperature Resolution 0.01 ℃ temperature accuracy ± 0.2 ℃ time resolution better than 1s Time Accuracy ±1s/h Start Mode Timing/Delay/Manual sampling interval 1s ~ 24 hours Data Storage ≥ 100000 group protection level IP68 Material 316L Stainless Steel Peek transmission mode wireless real-time Power supply mode battery; replaceable   Adapted instrument

Product Tags: Medical cleaning machine sterilizer calibration device , Clinical sterilizer calibration instrument , Healthcare cleaning machine calibration apparatus

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2006
Factory Size
1,000-3,000 square meters
Annual Export Value
Below US$1 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs