Ethylene Oxide Sterilizer Calibration Device
Ethylene Oxide Sterilizer Calibration Device
Product Introduction
ethylene oxide sterilizer uses the molecular diffusion of ethylene oxide gas to fill a certain concentration of ethylene oxide gas into the sterilization equipment compartment under suitable temperature, humidity and pressure conditions for low-temperature sterilization. The application of ethylene oxide sterilization equipment is very extensive, and it has a good sterilization effect on various microorganisms, including buds, bacteria, viruses and fungi, and the application covers biomedicine, medical equipment, and industrial production industries.
The company's self-developed ethylene oxide sterilizer calibration device meets the requirements of ethylene oxide sterilization equipment calibration specifications, using advanced temperature, humidity, pressure and other sensors and testing technology, can be the temperature of the sterilizer, relative humidity, pressure and other parameters for real-time measurement and calibration. The supporting software system can carry out real-time data acquisition, recording, calculation and statistical analysis, and support the generation of reports in line with calibration specifications to meet the testing, verification and calibration requirements of ethylene oxide sterilization equipment by measurement and calibration institutions and manufacturers.
Product Features
advanced sensor technology, high measurement accuracy
Multi-parameter wireless real-time data transmission, more convenient operation
widely suitable for different manufacturers, different models of equipment
intelligent management for data storage, analysis and reporting
Product Specifications
| Model | CY-CCO₂Hof mm.O | |
| temperature | Measurement range | (0~140)℃ |
| measurement accuracy | ± 0.1 ℃ | |
| resolution | 0.01 ℃ | |
| pressure | Measurement range | (0~700)kPa |
| measurement accuracy | ± 1.0kPa | |
| resolution | 0.1 kPa | |
| Humidity | Measurement range | (0~100)%RH |
| measurement accuracy | ±2.0%RH | |
| resolution | 0.1 %RH | |
| Ethylene Oxide Concentration | Measurement range | (0~1000)mg/L |
| measurement accuracy | ± 3% | |
| data transfer | wireless real-time | |
| sampling interval | 1s ~ 24 hours | |
| Data Export | supports raw data export to Excel files | |
| Calibration Report | Support Output | |
Send Inquiry to This Supplier
You May Also Like
-
Medical Centrifuge Calibration DeviceNegotiableMOQ: 1 Combo
-
Medical Centrifuge Calibration Device Made in ChinaNegotiableMOQ: 1 Combo
-
Medical Injection Pump and Infusion Pump DetectorNegotiableMOQ: 1 Combo
-
Cardio-encephalogram Signal SimulatorNegotiableMOQ: 1 Combo
-
Multi-parameter Vital Signs SimulatorNegotiableMOQ: 1 Combo
-
Blood Pressure Signal GeneratorNegotiableMOQ: 1 Combo
-
Maternal Fetal ECG Signal SimulatorNegotiableMOQ: 1 Combo
-
SECG 5.0 AIO ECG Performance TestingCNY 84000 - 85000MOQ: 1 Set
-
SECG 4.0 ECG Performance TestingCNY 49000 - 52000MOQ: 1 Set
-
MECG 2.0 Multi-channel ECG WaveformsCNY 49000 - 52000MOQ: 1 Set