I/O Number:
Foxboro FBM218/237 P0916QD
Place of Origin:
America
Communication Interface:
Modubus
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
I/O Number Foxboro FBM218/237 P0916QD
Place of Origin America
Communication Interface Modubus
Model Number Foxboro FBM218/237 P0916QD
Condition NEW
Warranty One Year
Package Original Packaging
HS Code 853890
Company's Order Placement Process and Guarantees
  • Warranty: 365 days

  • Delivery time: 1 week for in‑stock; no more than one month at the latest

  • Payment terms: 50% advance payment; full payment prior to delivery

  • Express options: FedEx, UPS, DHL

Key Features
  • Redundant output channels – FBM218/237 operate as a redundant pair to maintain communication if one path is lost.

  • Serial connectivity for third‑party systems – Typically supports RS‑485 (2‑/4‑wire) and RS‑232 for Modbus RTU master/slave links.

  • Seamless 200‑series integration – Plugs into standard Foxboro 200‑series baseplates; engineering and diagnostics via the DCS tools you already use.

  • Stable power via baseplate – 24 VDC nominal, supplied from the I/O baseplate for a clean, cabinet‑friendly install.

  • Designed for uptime – Automatic switchover in most cases, plus module health monitoring to help maintenance react before a process upset.

  • Noise‑tolerant wiring practices – Balanced RS‑485 and shielded cable guidance help in electrically noisy plants.

Technical Specifications
Brand / Model Foxboro FBM218/237, Part No. P0916QD
HS Code 8538.90 (parts for industrial control equipment)
Power Requirements 24 VDC nominal via 200‑series baseplate; module power typically
Dimensions & Weight Standard 200‑series single‑wide FBM form factor; approx. 0.55 kg
Operating Temperature 0 to 60 °C (typical), 5–95% RH non‑condensing
Signal Input/Output Types Digital serial communication outputs; no analog/DI/DO field channels
Communication Interfaces RS‑485 (2‑/4‑wire) and RS‑232; Modbus RTU (master/slave) commonly applied; configurable baud/format
Installation Method Plug‑in to Foxboro 200‑series baseplate (P0916‑series); baseplate DIN‑rail or panel mounted; redundant pair in adjacent slots
Application Fields

This module pair is typically used where the Foxboro DCS must communicate to third‑party subsystems with high availability:

  • Linking process units to PLC‑based skids (compressors, boilers, water treatment packages)

  • Drive/MCC communication for speed control, start/stop, and status collection

  • Data exchange with building utilities and OEM equipment in chemical, oil & gas, power, and pharma facilities

  • Brownfield upgrades where Modbus serial remains the fastest, most practical path

D1F2A77952A7729F5FB225D562FE4249

Advantages & Value
  • Reliability – Redundant comms reduce single points of failure; switchover is smooth in most cases.

  • Compatibility – Fits existing 200‑series infrastructure; works with common Modbus RTU devices.

  • Cost control – Keeps legacy links running without forcing a full network redesign, saving cabinet space and engineering hours.

  • Maintainability – Diagnostics through Foxboro tools help technicians pinpoint wiring or device issues faster.

A maintenance supervisor at a refinery told us their redundant FBM218/237 setup “survived” a panel power dip—one side recovered instantly and the PLC link never dropped. That’s the kind of quiet resilience plants count on.

Installation & Maintenance
  • Cabinet & environment – Install on standard 200‑series baseplates with adequate ventilation; maintain ambient 0–60 °C.

  • Wiring – Use twisted‑pair, shielded cable for RS‑485; terminate at the bus ends only; keep RS‑232 runs short.

  • Grounding – Bond shields at a single point to avoid ground loops; separate power and signal routing where possible.

  • Redundancy layout – Place the pair in adjacent slots; verify active/standby status in engineering tools after commissioning.

  • Routine checks – Periodically verify link quality, error counts, and baud/format settings; clean connectors during planned outages.

  • Firmware/config – Keep configurations backed up; apply firmware updates during maintenance windows if recommended by the OEM.

Quality & Certifications
  • CE compliant

  • UL/cUL recognized (industrial control)

  • CSA compliance (where applicable)

  • Manufacturing quality aligned with ISO 9001 practices

Certification scope can vary slightly by production batch or region; in many cases, the documentation set with the module or the OEM datasheet will confirm the exact marks for your site standards.

Product Tags: Foxboro FBM218/237 P0916QD , FBM218/237 P0916QD , P0916QD

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2014
Annual Export Value
US$2.5 Million - US$5 Million
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs