Home > Electrical & Electronics > Relay & Contactor > Relay > Foxboro FBMSSW Field Bus Module – Reliable FOUNDATION Fieldbus Connectivity for Foxboro DCS

Foxboro FBMSSW Field Bus Module – Reliable FOUNDATION Fieldbus Connectivity for Foxboro DCS

Foxboro FBMSSW Field Bus Module – Reliable FOUNDATION Fieldbus Connectivity for Foxboro DCS photo-1
Foxboro FBMSSW Field Bus Module – Reliable FOUNDATION Fieldbus Connectivity for Foxboro DCS photo-2
Foxboro FBMSSW Field Bus Module – Reliable FOUNDATION Fieldbus Connectivity for Foxboro DCS photo-3
Foxboro FBMSSW Field Bus Module – Reliable FOUNDATION Fieldbus Connectivity for Foxboro DCS photo-4
US$ 2880 ≥1 Blade
Key Specifications
Get Latest Price
I/O Number:
Foxboro FBMSSW
Place of Origin:
America
Communication Interface:
Modubus
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
I/O Number Foxboro FBMSSW
Place of Origin America
Communication Interface Modubus
Model Number Foxboro FBMSSW
Condition NEW
Warranty One Year
Package Original Packaging
HS Code 853710
Company's Order Placement Process and Guarantees
  • Warranty: 365 days

  • Lead time: typically 1 week if in stock; no more than one month at the latest

  • Payment terms: 50% advance payment; full payment prior to delivery

  • Express delivery: FedEx, UPS, DHL

Key Features
  • FOUNDATION Fieldbus H1 segments – Supports FF H1 (31.25 kbps) for direct connection of compliant field devices on shielded twisted pair.

  • Redundant architecture ready – Can be deployed as a redundant pair to improve availability in critical loops, which in many cases reduces unplanned downtime.

  • Galvanic isolation – Segment-to-system isolation helps protect the controller bus from field disturbances and ground noise.

  • Fits Foxboro Series 2 baseplates – Single‑wide mechanical format for quick installation, swap, and spares management.

  • Integrated diagnostics – Status LEDs and system diagnostics simplify commissioning and troubleshooting at the cabinet.

  • Flexible field wiring – Works with standard Foxboro termination assemblies, keeping wiring neat and serviceable.

  • Broad device compatibility – Interoperates with most FOUNDATION Fieldbus H1 instruments when configured according to IEC 61158‑2 practices.

Technical Specifications
Brand / Model Foxboro FBMSSW Field Bus Module
HS Code 8537.10 (Boards/panels for electric control, for industrial use)
Power Requirements Nominal 24 VDC supplied via Foxboro Series 2 FBM baseplate (consumption typically
Operating Temperature 0 to 60 °C (cabinet‑mounted; non‑condensing humidity)
Signal I/O Types FOUNDATION Fieldbus H1 segments (shielded twisted pair), galvanically isolated from system bus
Communication Interfaces FF H1 31.25 kbps on field side; Foxboro FBM backplane/system bus on baseplate side
Mechanical Format Single‑wide Foxboro FBM module; plug‑in to Series 2 baseplate
Installation Method DIN‑rail‑mounted baseplate with field wiring through a termination assembly; supports redundant pairing
Compliance CE, UL, RoHS (configuration and label dependent; many units rated for Class I, Div 2 / Zone 2)
Application Fields

Plants that standardize on Foxboro DCS and run mixed protocols typically use FBMSSW to add and maintain FF H1 networks at the controller level:

  • Oil & Gas: wellhead RTU tie-ins, separators, and pipeline stations with FF instruments.

  • Chemicals & Petrochem: reactor temperature/flow loops with interoperable FF transmitters and positioners.

  • Power & Utilities: water/steam cycle monitoring with digital valve positioners over FF.

  • Pharma & Biotech: skid integration where OEMs supply FF devices with GAMP-compliant documentation.

One thing I appreciate is how it supports migration projects—teams can keep the baseplate and simply slide in the module, then commission FF devices segment by segment. A maintenance lead recently mentioned that moving from a mixed HART/FF layout to full FF on one unit cut their cabinet wiring time by about 20%.

D1F2A77952A7729F5FB225D562FE4249

Advantages & Value
  • Reliability – Redundant-ready design and isolation reduce process interruptions in most cases.

  • Compatibility – Works within the Foxboro FBM ecosystem and with standard FF H1 field devices.

  • Lifecycle cost control – Reuses existing baseplates and terminations; minimizes cabinet rework, which typically lowers install costs.

  • Diagnostics & commissioning – Segment health indicators and system diagnostics speed up loop check and device replacement.

  • Support & spares – Single‑wide format simplifies stocking; easy module swap keeps downtime short.

Installation & Maintenance
  • Cabinet & environment – Mount on Series 2 baseplate in a ventilated panel; 0–60 °C, non‑condensing. Provide clean ground and surge protection.

  • Wiring – Use FOUNDATION Fieldbus Type A shielded twisted pair; two terminators per segment; avoid star topologies unless using compliant couplers.

  • Segment power – Feed FF segments via certified power conditioners/isolators; do not draw device power directly from the module.

  • Redundancy – For high availability, deploy as a redundant pair on separate power feeds and route segments distinctly where practical.

  • Safety – De‑energize before insertion/removal; for hazardous areas, ensure the exact module and accessories carry the appropriate Div/Zone markings.

  • Routine maintenance – Check segment current and noise levels, clean terminals annually, review device firmware/DTMs, and keep spares tested.

From my experience, most commissioning issues trace back to improper segment termination or shielding. A quick scope check on the H1 waveform often saves hours.

Quality & Certifications
  • Conformity: CE and UL; RoHS compliant on most current production units

  • Typical installation ratings: Class I, Division 2 / ATEX Zone 2 (verify the nameplate on the exact module variant)

  • Manufacturer warranty: 12 months (365 days)

Suggested Supporting Components
  • Foxboro Series 2 baseplate (DIN‑rail mounted), single‑wide slots

  • FOUNDATION Fieldbus power conditioner/segment coupler with integrated terminators

  • Termination assembly (TA) compatible with FF H1 field wiring

  • Shielded twisted pair Type A FF cable and approved surge protection for outdoor runs

Note: Specifications above reflect the Foxboro FBM family behavior for FF H1 modules and, in most cases, match FBMSSW deployments. If your site has a specific build code or hazardous-area rating requirement, share it and I’ll align the exact variant.

Product Tags: Foxboro FBMSSW , FBMSSW

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2014
Annual Export Value
US$2.5 Million - US$5 Million
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs