Home > Instruments & Meters > Meter for Liquid & Gas > Flow Meter > Non-Contact Clamp-On Ultrasonic Flow Meter for Liquids/Gases, 4-20mA/RS485 Output, Battery-Powered Option Available

Non-Contact Clamp-On Ultrasonic Flow Meter for Liquids/Gases, 4-20mA/RS485 Output, Battery-Powered Option Available

Non-Contact Clamp-On Ultrasonic Flow Meter for Liquids/Gases, 4-20mA/RS485 Output, Battery-Powered Option Available photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Type:
Electromagnetic Flow Meter
Application:
Industrial Production
Accuracy:
±0.2-0.5%
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Type Electromagnetic Flow Meter
Application Industrial Production
Accuracy ±0.2-0.5%

Ultrasonic Flowmeter Series

The ultrasonic flowmeter is a device that measures the flow of liquid in a pipe by using the principle of velocity difference. It can be divided into external clamp type, portable type and pipeline type. It is often used in combination with digital signal processing technology, multi - pulse technology and error correction technology to adapt to the environment and enhance reliability.

超声波流量计_副本.png

Application

At present, the product series includes ultrasonic water meters, ultrasonic flowmeters and ultrasonic heat meters. Among them, water meters, flowmeters and heat meters can be selected with single - channel and dual - channel. Now it has been widely used in automation control, chemical industry, electric power, petroleum, metallurgy and other fields.


Technical Performance

Item

Performance and Parameters

Principle

Using the principle of ultrasonic timing difference, 4 - wire 18F27J54 single - chip microcomputer

Accuracy

Flow: ± 1% (when the electrical signal is better than 2%), repeatability: 0.2%

Display

Optional 2 * 10 character type or 16 * 240 dot matrix type liquid crystal display, 96 * 192 dot matrix type liquid crystal display

Output Signal

4 - 20mA, accuracy 0.1%, resolution 0.1%Pulse output: square wave, pulse equivalent and quantity can be set, internal and external OCT outputFrequency output: 1 - 9999Hz optional, OCT outputAlarm output: dual OCT output, optional 20 kinds of signals

Host Signal Input

Can input 3.3V - 20mA electrical signal, accuracy ± 0.1% (can collect temperature, pressure, liquid level and other signals)Can be equipped with RS485 interface: MODBUS standard communicationCan be equipped with HART interface 1: can communicate with HART protocol software

Host Interface

RS485 interface, can connect PC and flow calculation software for parameter setting, support MODBUS, METER - BUS protocolSelf - diagnosis: self - check interface, can display 12 items, 10 groups of historical data or heat data

Other Functions of Host

Automatically memorize whether the working state of the flowmeter in the past 32 days is normalAutomatically memorize the power failure time and flow rate for 32 times, and can perform manual or automatic compensation to reduce user flow or heat lossProgrammable (remote) control: There are 10 kinds of output signals, including the use of external input signals or MODBUS commands to perform quantitative control

Special Cable

Customized cable: generally reduced by 50 meters, the specific cooperation distance can be extended by 5000 meters, not recommended; using RS485 communication, the transmission distance can reach above the water meter

Pipeline Situation

Pipe material: steel, stainless steel, cast iron, water pipe, copper, PVC, aluminum, glass, etc. pipes of all qualities are allowed, and lining pipes are allowedPipe inner diameter: 15 - 6000mmStraight pipe section: The sensor installation point is best satisfied: upstream 10D, downstream 5D, and the distance from the outlet 50D (D is the pipe diameter)

Measuring Medium

Water, sewage, industrial wastewater, acid - base liquid, alcohol, various oils and other uniform media that can conduct ultrasonic waves

Measuring Range

Temperature: low temperature head: - 30 - 80℃, high temperature head: - 30 - 160℃Pressure: 10000mm air column full range

Working Environment

Flow rate: 0 - 30m/sFlow direction: positive and negative flow measurement, and can calculate the net flow accumulationAmbient temperature: - 25 - 70℃Weight sensor: - 40℃ - 160℃ temperature transmitter; specified according to customer needsHost: RS485Flow sensor: can work underwater, water depth ≤ 5m

Fixed Mode

Fixed type: flow sensor; split type: flow sensor

Power Supply

Local: 24VDC: 8 - 36VDC; 8 - 36VDC; 85 - 264VAC; 3.6V lithium batteryModule: 10 - 30VDC; 24VDCExternal: RS485

Power

Less than 1.5W


Product Tags: Ultrasonic flowmeter , industrial instrument , Flow Meter Portable Flowmeter

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Platinum Verified Supplier
1Yr
Verified Business License
Business Type
Agent
Year Established
2015
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Shanghai, China

Recommended Categories

Explore top categories and find suppliers for your specific needs