Home > Electrical & Electronics > Electrical Control System > PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Single-Phase Power Module

PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Single-Phase Power Module

PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Single-Phase Power Module photo-1
PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Single-Phase Power Module photo-2
PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Single-Phase Power Module photo-3
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Material:
Other, Global universal model
Condition:
Other, Global universal model
Task:
Other, Global universal model
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Material Other, Global universal model
Condition Other, Global universal model
Task Other, Global universal model
Mathematical Model Other, Global universal model
Signal Other, Global universal model
Customized Non-Customized
Structure Other, Global universal model
Operating Temperature -20 to 70°C
Dimensions 270 x 260 x 40mm
Weight 3.87kg
PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01
Overview
This power module is renowned for its high efficiency, reliability, and compact design, suitable for multiple fields including industrial automation, communication equipment, and medical devices. It provides stable and reliable power for devices such as control systems, sensors, base stations, and routers.
Functional Features
  • Adopts high-quality materials and advanced manufacturing processes, with anti-vibration and moisture-proof capabilities to ensure stable operation in harsh environments.

  • Enables efficient power conversion, providing stable voltage and current output.

  • Supports programming for configuration and control, facilitating easy setup and debugging.

  • Features multi-channel output, enabling simultaneous power supply for multiple devices to enhance system integration and flexibility.

PM3326B-6-1-2-E (3)

Technical Parameters
  • Input Voltage: 90 to 264VAC

  • Input Current: 18.2A

  • Output Voltage: 56VDC

  • Output Current: 17.9A

  • Output Power: 1000W

  • Efficiency: 90%

  • Operating Temperature: -20 to 70°C

  • Storage Temperature: -40 to 85°C

  • Humidity: 5% to 95% RH (non-condensing)

  • Dimensions: 270 x 260 x 40mm

  • Weight: 3.87kg

  • Isolation Voltage: 2kVrms

  • Ripple and Noise:

  • Hold-up Time: 20ms

  • Protection Functions: Overvoltage protection, short-circuit protection

  • Cooling Method: Natural convection

Working Principle
The power module converts 90 to 264VAC alternating current to 56VDC direct current through an isolated front-end (IFE) AC input. During conversion, internal circuits and components process the input power to ensure stable output voltage and current, while relevant circuits implement protection functions against overvoltage, overcurrent, and short circuits. Its high-efficiency conversion characteristics enable efficient conversion of input power into useful output power, reducing energy waste.

PM3326B-6-1-2-E (1)

Common Faults and Solutions1. No Magnetic Field Output or Abnormal Output
  • Possible Causes:
    • Power connection failure (e.g., unstable input voltage, loose or shorted wiring).

    • Internal coil open circuit or short circuit (insulation damage due to long-term overload or high temperature).

    • Control circuit component failure (e.g., driver IC, relay).

  • Solutions:
    • Check if the input voltage meets technical parameters (refer to the rated voltage range) and ensure wiring is secure, free of damage or oxidation.

    • Use a multimeter to test coil resistance; if abnormal (e.g., infinite resistance or far below the nominal value), replace the coil or the entire component.

    • Inspect components on the control circuit board (e.g., bulging capacitors, overheated chips), and replace damaged components or contact the manufacturer for repair if necessary.

2. Unstable or Decaying Magnetic Field Strength
  • Possible Causes:
    • Aging of core materials or decreased magnetic permeability (magnetic loss due to long-term high-frequency use).

    • Excessive coil temperature from poor heat dissipation, affecting magnetic flux stability.

    • External electromagnetic interference (e.g., nearby strong magnetic field devices).

  • Solutions:
    • Check the core surface for rust or cracks; replace the core or entire component if severely aged.

    • Verify that the cooling fan operates normally, clean dust from cooling holes, and ensure the device works within the rated temperature range (refer to technical parameters).

    • Add an electromagnetic shielding layer (e.g., metal housing) and keep the device away from interference sources (e.g., transformers, frequency converters).

PM3326B-6-1-2-E (4)

3. Unusual Noise or Excessive Vibration During Operation
  • Possible Causes:
    • Loose assembly of the core and coil (fixing screws loosened by long-term vibration).

    • Magnetic circuit design flaws or loose lamination of core silicon steel sheets, causing magnetostrictive noise.

    • Unbalanced mechanical components of the load (e.g., matched motor, transmission device) triggering resonance.

  • Solutions:
    • After shutdown, check and retighten component fixing screws, adding threadlocker if necessary, and replace fasteners if needed.

    • If it is a design issue, contact the manufacturer to confirm if an upgraded version is available or adjust the installation method (e.g., add vibration-damping pads).

    • Check the dynamic balance of the load equipment and repair or replace unbalanced components (e.g., rotors, gears).

4. Frequent Overheat Protection Activation
  • Possible Causes:
    • Coil current exceeding the rated value (overload operation or control circuit abnormality).

    • Failure of the cooling system (fan stop, dust accumulation on heat sinks).

    • Excessive ambient temperature or poor ventilation.

  • Solutions:
    • Monitor working current with an ammeter; if exceeding the rated value, check for load overload or control circuit short circuit, repair and restart the device.

    • Clean dust from heat sinks and fan blades, replace damaged fans, and ensure unobstructed cooling channels.

    • Improve the device installation environment by adding ventilation equipment (e.g., axial fans) or installing a temperature monitoring system to ensure the ambient temperature stays within the technical parameters.

Product Tags: PIONEER MAGNETICS , PM3326B-6-1-2-E , 80026-529-01

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2014
Factory Size
1,000-3,000 square meters
Product Certifications
SA8000