Accueil > Électrique et électronique > Système de contrôle électrique > PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Module d'alimentation monophasé

PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Module d'alimentation monophasé

PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Module d'alimentation monophasé photo-1
PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Module d'alimentation monophasé photo-2
PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01 Module d'alimentation monophasé photo-3
Négociable MOQ: 1 Piece (Prix négociable en fonction du volume de commande et de la personnalisation)
Spécifications Clés
Obtenir le dernier prix
Operating Temperature:
-20 à 70°C
Dimensions:
270 x 260 x 40mm
Weight:
3.87kg
Paiement et Livraison
Modes de Paiement:
Port d'Expédition:
China
Détails de livraison:
Le délai de livraison dépend de la quantité commandée.
Operating Temperature -20 à 70°C
Dimensions 270 x 260 x 40mm
Weight 3.87kg
PIONEER MAGNETICS PM3326B-6-1-2-E 80026-529-01
Aperçu
Ce module d'alimentation est réputé pour son haut rendement, sa fiabilité et sa conception compacte, adapté à de multiples domaines, notamment l'automatisation industrielle, les équipements de communication et les dispositifs médicaux. Il fournit une alimentation stable et fiable pour des appareils tels que les systèmes de contrôle, les capteurs, les stations de base et les routeurs.
Caractéristiques fonctionnelles
  • Adopte des matériaux de haute qualité et des procédés de fabrication avancés, avec des capacités anti-vibrations et anti-humidité pour garantir un fonctionnement stable dans des environnements difficiles.

  • Permet une conversion d'énergie efficace, fournissant une sortie de tension et de courant stable.

  • Prend en charge la programmation pour la configuration et le contrôle, facilitant la mise en place et le débogage.

  • Caractérise par une sortie multi-canaux, permettant d'alimenter simultanément plusieurs appareils pour améliorer l'intégration et la flexibilité du système.

PM3326B-6-1-2-E (3)

Paramètres techniques
  • Tension d'entrée : 90 à 264VAC

  • Courant d'entrée : 18,2A

  • Tension de sortie : 56VDC

  • Courant de sortie : 17,9A

  • Puissance de sortie : 1000W

  • Rendement : 90%

  • Température de fonctionnement : -20 à 70°C

  • Température de stockage : -40 à 85°C

  • Humidité : 5% à 95% HR (non condensante)

  • Dimensions : 270 x 260 x 40mm

  • Poids : 3,87kg

  • Tension d'isolation : 2kVrms

  • Ripple et bruit :

  • Hold-up Time: 20ms

  • Protection Functions: Overvoltage protection, short-circuit protection

  • Cooling Method: Natural convection

Working Principle
The power module converts 90 to 264VAC alternating current to 56VDC direct current through an isolated front-end (IFE) AC input. During conversion, internal circuits and components process the input power to ensure stable output voltage and current, while relevant circuits implement protection functions against overvoltage, overcurrent, and short circuits. Its high-efficiency conversion characteristics enable efficient conversion of input power into useful output power, reducing energy waste.

PM3326B-6-1-2-E (1)

Common Faults and Solutions1. No Magnetic Field Output or Abnormal Output
  • Possible Causes:
    • Power connection failure (e.g., unstable input voltage, loose or shorted wiring).

    • Internal coil open circuit or short circuit (insulation damage due to long-term overload or high temperature).

    • Control circuit component failure (e.g., driver IC, relay).

  • Solutions:
    • Check if the input voltage meets technical parameters (refer to the rated voltage range) and ensure wiring is secure, free of damage or oxidation.

    • Use a multimeter to test coil resistance; if abnormal (e.g., infinite resistance or far below the nominal value), replace the coil or the entire component.

    • Inspect components on the control circuit board (e.g., bulging capacitors, overheated chips), and replace damaged components or contact the manufacturer for repair if necessary.

2. Unstable or Decaying Magnetic Field Strength
  • Possible Causes:
    • Aging of core materials or decreased magnetic permeability (magnetic loss due to long-term high-frequency use).

    • Excessive coil temperature from poor heat dissipation, affecting magnetic flux stability.

    • External electromagnetic interference (e.g., nearby strong magnetic field devices).

  • Solutions:
    • Check the core surface for rust or cracks; replace the core or entire component if severely aged.

    • Verify that the cooling fan operates normally, clean dust from cooling holes, and ensure the device works within the rated temperature range (refer to technical parameters).

    • Add an electromagnetic shielding layer (e.g., metal housing) and keep the device away from interference sources (e.g., transformers, frequency converters).

PM3326B-6-1-2-E (4)

3. Unusual Noise or Excessive Vibration During Operation
  • Possible Causes:
    • Loose assembly of the core and coil (fixing screws loosened by long-term vibration).

    • Magnetic circuit design flaws or loose lamination of core silicon steel sheets, causing magnetostrictive noise.

    • Unbalanced mechanical components of the load (e.g., matched motor, transmission device) triggering resonance.

  • Solutions:
    • After shutdown, check and retighten component fixing screws, adding threadlocker if necessary, and replace fasteners if needed.

    • If it is a design issue, contact the manufacturer to confirm if an upgraded version is available or adjust the installation method (e.g., add vibration-damping pads).

    • Check the dynamic balance of the load equipment and repair or replace unbalanced components (e.g., rotors, gears).

4. Frequent Overheat Protection Activation
  • Possible Causes:
    • Coil current exceeding the rated value (overload operation or control circuit abnormality).

    • Failure of the cooling system (fan stop, dust accumulation on heat sinks).

    • Excessive ambient temperature or poor ventilation.

  • Solutions:
    • Monitor working current with an ammeter; if exceeding the rated value, check for load overload or control circuit short circuit, repair and restart the device.

    • Clean dust from heat sinks and fan blades, replace damaged fans, and ensure unobstructed cooling channels.

    • Improve the device installation environment by adding ventilation equipment (e.g., axial fans) or installing a temperature monitoring system to ensure the ambient temperature stays within the technical parameters.

Étiquettes de produit: PIONEER MAGNETICS , PM3326B-6-1-2-E , 80026-529-01

Envoyer une demande à ce fournisseur

Message
0/5000

Voulez-vous le meilleur prix? Publiez un RFQ maintenant !
Fournisseur Vérifié Or
1An
Licence Commerciale Vérifiée
Type d'entreprise
Trading Company
Année de création
2014
Taille de l'usine
1 000 - 3 000 mètres carrés
Certifications de Produit
SA8000