PCD231B101 3BHE025541R0101
Brand: ABB
Type:PCD231B101 3BHE025541R0101
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
SFD Torque/Current Mode The S200 can drive a brushless motor in Torque/Current Mode using SFD Feedback. The drive can be configured either with the S200Tools over the serial port or configured using the S1 and S2 switches. Configuring the drive with the S200Tools utility provides increased flexibility in setting parameters that are not available through the setup switches. When using the S200Tools utility, the configuration parameters should be saved to non-volatile memory (click the NV Save button) to allow the configuration to be recalled on power up. To configure the drive for Current Mode with SFD feedback, set the following parameters: Parameter Value CommMode SetupS2-2 (Default value) with switch S2-2 set to the down position labeled, S on the drive. or SFD CommOff 0 Degrees – for AKM motor series, check with your sales representative for the correct commutation offset angle for other motor series. OpMode SetupS2-1 with switch S2-1 set to the down position labeled, I, on the drive. or Current SelSFDParam SFD (Default value) – recommended setting. This setting will automatically set the motor parameters. To change motor parameters refer to Configuring with SFD Feedback Motor Parameters. CmdSrc Sets the source of the command. CmdGain Sets the command gain for the command input. CmdOffset Sets the command offset for the command input. CMDF0 Sets the filtering on analog input commands. The following are optional parameters that can be set. Parameter Function EncOut Sets the line count of the emulated encoder output. EnInhibitCW EnInhibitCCW Enables the hardware over travel limits.

Send Inquiry to This Supplier
You May Also Like
-
PFTL101B 5.0KN 3BSE004191R1US$ 5016 - 5027MOQ: 1 Piece
-
PFTL101A 1.0KN 3BSE004166R1US$ 1100 - 2010MOQ: 1 Piece
-
07KT97 GJR5253000R4270US$ 1103 - 2013MOQ: 1 Piece
-
07KT98 GJR5253100R4278US$ 1103 - 2013MOQ: 1 Piece
-
07KT98 H2 GJR5253100R0278US$ 1103 - 2013MOQ: 1 Piece
-
07KT98C GJR5253100R028US$ 1103 - 2013MOQ: 1 Piece
-
5SHY3545L0016 3BHB019719R0101 GVC736BE101 5SXE06-0160US$ 1104 - 2014MOQ: 1 Piece
-
KUC711AE 3BHB004661R0001US$ 1104 - 2014MOQ: 1 Piece
-
KUC711AE01 3BHB004661R0001US$ 1104 - 2014MOQ: 1 Piece
-
KUC711AE101 3BHB004661R0101US$ 1104 - 2014MOQ: 1 Piece