Brand:ABB
Type:PM865K01 3BSE031151R1
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Remote Cascade Setpoint The Cascade setpoint can be positioned through an analog signal. Optionally, one of the 505E’s analog inputs can be programmed to position the Cascade PID setpoint. This allows the Cascade setpoint to be positioned remotely by a process control or distributed plant control system. The Remote Cascade Setpoint (RCS) range is determined by the programmed Analog input’s 4 mA and 20 mA settings. The Remote Cascade Setpoint range is tunable in the Service mode, but cannot be set outside of the min and max Cascade Setpoint settings. The Remote Cascade Setpoint input may be enabled from the 505E keypad, contact input, or Modbus communications. The last command given from any of these three sources dictates enable/disable. If the milliamp signal to the Remote Cascade setpoint input is out of range (below 2 mA or above 22 mA) an alarm will occur and the Remote Cascade setpoint will be inhibited until the input signal is corrected and the alarm is cleared. Remote Casc Setpt Messages Depending on configuration and system conditions, the Remote Cascade Setpoint may be in one of the following states (505E front panel screen messages): • Disabled—The Remote Setpoint function is not enabled and will have no effect on the Cascade setpoint. • Enabled—The Remote Setpoint has been enabled but cascade control is not active. The breakers are not closed, speed
Send Inquiry to This Supplier
You May Also Like
-
SA168 3BSE003389R1US$ 1049 - 2268MOQ: 1 Piece
-
SM811K01 3BSE018173R1US$ 1049 - 2268MOQ: 1 Piece
-
TB850 3BSC950193R1US$ 1049 - 2268MOQ: 1 Piece
-
LC-608US$ 1064 - 2053MOQ: 1 Piece
-
DSAI130D 3BSE003127R1US$ 1065 - 2054MOQ: 1 Piece
-
DSAO120A 3BSE018293R1US$ 1065 - 2054MOQ: 1 Piece
-
DSBC176 3BSE019216R1US$ 1065 - 2054MOQ: 1 Piece
-
DSDI110AV1 3BSE018295R1US$ 1065 - 2054MOQ: 1 Piece
-
DSDI146 3BSE007949R1US$ 1065 - 2054MOQ: 1 Piece
-
DSDO115A 3BSE018298R1US$ 1066 - 2057MOQ: 1 Piece