Brand:ICS TRIPLEX
Type:T8231
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Cascade Setpoint Tracking To allow a bumpless transfer from turbine Speed/load control to Cascade control, the Cascade PID can be programmed to track its controlling process input when disabled. When this tracking feature is programmed, the Cascade PID will be satisfied when enabled, and no turbine speed or load correction will be performed. After the Cascade control is enabled, its setpoint can be moved as required to another setting. Cascade Setpoint with No Tracking If the Cascade control is programmed not to use the setpoint tracking feature, the setpoint will remain at its last setting (running or shutdown). When the 505E is powered-up the setpoint is reset to the ‘Setpt Initial Value’. With this configuration, when Cascade control is enabled, and the sensed process signal does not match setpoint, the Cascade control will ramp turbine speed/load up or down to match the two signals, at a controlled “not- matched” rate (defaulted to the ‘Speed Setpoint Slow Rate’ setting, and tunable through the Service mode). If Cascade is the controlling parameter and one of the permissives is lost or Cascade is disabled, the speed setpoint will remain at the last setting until another parameter adjusts it. Cascade Droop When sharing control of a parameter with another external controller, the Cascade PID can also receive a programmable DROOP feedback signal for control loop stability. This feedback signal is a percentage of the Cascade PID’s output. By including this second parameter into the control loop, the Cascade PID becomes satisfied, and does not fight with the other external controller over the shared parameter.

Send Inquiry to This Supplier
You May Also Like
-
ICS TRIPLEX T9402US$ 1153 - 2053MOQ: 1 Piece
-
ICS TRIPLEX T9432US$ 1153 - 2053MOQ: 1 Piece
-
ICS TRIPLEX T9451US$ 1153 - 2053MOQ: 1 Piece
-
ICS TRIPLEX T8110BUS$ 1158 - 2058MOQ: 1 Piece
-
ICS TRIPLEX T8461US$ 1159 - 2059MOQ: 1 Piece
-
PM865K01 3BSE031151R1US$ 1047 - 2267MOQ: 1 Piece
-
3BHL000986P0006US$ 1047 - 2267MOQ: 1 Piece
-
5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101US$ 1047 - 2267MOQ: 1 Piece
-
5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC750BE101US$ 1047 - 2267MOQ: 1 Piece
-
5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101US$ 1047 - 2267MOQ: 1 Piece