Home > Products > Spectrophotometer > Integrated AAS with Flame and Graphite Furnace
Integrated AAS with Flame and Graphite Furnace
- 100 Piece / Pieces per Month
- Shanghai
- T/T Credit Card
- Flame Graphite Furnace Integral Atomic Absorption Spectrophotometer
- Automated Control AAS With Automatic Graphite Furnace And 6 Lamps Turret
- Flame Graphite Furnace Atomic Absorption Spectrophotometer With 6 Lamps Turret
- Atomic Absorption Spectrophotometer With Automatic Graphite Furnace& 6 Lamps Turret For Flame Mode
- Flame Graphite Furnace Atomic Absorption Spectrophotometer with 6 lamps turret
- Atomic Absorption Apectrophotometer (AAS) Price
Product Details
Brand Name: | Drawell | Place of Origin: | Shanghai, China | Model Number: | DW-AAS-110A |
Size: | 1020*490*540mm, 420*420*460 mm | Weight: | 80Kg/ 50Kg | Wavelength Range: | 190-900nm |
Focal Length: | 277mm |
Product Description
Flame/Graphite Furnace Atomic Absorption Spectrophotometer
DW-AAS-110A/120A/130A
FEATURES:
Innovated Rich oxygen air-acetylene flame analysis technique (DW-AAS-110A)
The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950℃, which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame is will not pollute the environment and is not harmful to human bodies. It’s a break-through in flame AAS analysis.
Integrated flame/graphite furnace atomization system, changeable with flame emission burner
· Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor.
· A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc. (DW-AAS-110A/120A)
Accurate fully automated control system
· Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position. · Automatic wavelength scanning and peak picking
· Automatic spectral bandwidth changing
· Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, and automatic ignition
Reliable fully automatic graphite furnace analysis
· Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%.
· Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact.
Perfect safety protection measures
· Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system;
· Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling water supply and over-heating in graphite furnace system.
Advanced and reliable electronic design
· Adopting large-scale programmable logic array and Inter I2C bus technology
· European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.
Easy and practical analysis software
· Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
· Automatic display of measured data, automatic calculation and analytical result automatic print out.
SPECIFICATIONS:
Main Specification |
Wavelength range |
190-900n |
Wavelength accuracy |
±0.25nm |
|
Resolution |
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. |
|
Baseline stability |
≤0.004A/30min |
|
Background correction |
The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. (only for WFX-110A/120A) |
|
Hollow Cathode Lamps |
Lamp turret |
6-lamp turret (DW-AAS-110A/120A), 4-lamp turret (DW-AAS-130A) Auto-alignment, fully automated scan and peak-picking. |
Lamp current adjustment |
Automatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA |
|
Lamp power supply mode |
400Hz square wave pulse 100Hz Narrow square wave pulse + 400Hz wide square wave pulse (DW-AAS-110A/120A) |
|
Optical System |
Monochomator |
Single beam, Czerny-Turner design grating monochromator |
Grating |
1800 l/mm |
|
Focal length |
||
Blazed Wavelength |
250nm |
|
Spectral Bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change. |
|
Flame Atomizer |
Burner |
10cm single slot all-titanium burner |
Spray chamber |
Corrosion resistant all-plastic spray chamber. |
|
Nebulizer |
High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min |
|
Provided with DW-AAS-110A/120A |
||
Graphite Furnace |
Temperature range |
Room temperature~3000ºC |
Heating rate |
2000℃/s |
|
Graphite tube dimensions |
28mm (L) x 8mm (OD) |
|
Characteristic mass |
Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g |
|
Precision |
Cd≤3%, Cu≤3%, Mo≤4% |
|
Detection and Data Processing System |
Detector |
R928 Photomultiplier with high sensitivity and wide spectral range. |
Software |
Windows operating system |
|
Analytical method |
Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. |
|
Repeat times |
Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation. |
|
Multi-task function |
Sequential measurement of multi-elements in one sample |
|
Condition reading |
With model function |
|
Result printing |
Measurement data and final analytical report printout, editing with Excel. |
|
Standard RS-232 serial port communication |
||
Characteristic Concentration and Detection Limit |
Normal Air-C2H2 flame |
Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L; |
Oxygen-rich Air-C2H2 flame |
Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L (for WFX-110A) |
|
Function Expansion |
Hydride vapor generator can be connected for hydride analysis. |
|
Dimensions and weight |
1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg 420 (L) × 420 (W) × 460 (H) mm (graphite furnace), unpacked 50kg |
Contact Us
- Chongqing Drawell Instrument Co., Ltd.
- Flame AAS Atomic Absorption Spectrophotometer DW-AA4530F
- Atomic Absorption Spectrophotometer (AAS) Price
- Double Beam Atomic Absorption Spectrophotometer
- AAS Atomic Absorption Spectrophotometer Price
- Atomic Absorption Spectrophotometer Price
- Nanodrop Spectrophotometer Price For Lab
- Wholesale Nano Spectrophotometer For DNA Testing
- DNA Testing Instrument Equipment Machine MD2000
- Wholesale DNA Protein Testing Equipment Manufacturer
- DW-K5500Plus Micro Volume Spectrophotometer
- Nanodrop Spectrophotometer Price For Lab
- Fourier Transform Infrared Spectrometer Machine Price
Popular Searches
- spectrophotometer
- infrared spectrometer
- spectrometer
- vis spectrophotometer
- photometer
- visible spectrophotometer
- lumen tester
- Fluorescence Spectrophotometer
- Double Beam Spectrophotometer
- Uv Spectrophotometer
- Single Beam Spectrophotometer
- Scanning Spectrophotometer
- Portable Spectrophotometer
- Grating Spectrophotometer
- Aas Spectrophotometer
- Spectrometers
Find Similar Products By Category
- Measurement & Analysis Instruments > Optical Instruments > Spectrometers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-