532nm High Energy Green For Liquid Analysis Laser
LIBS is an atomic emission spectrocopy technique.Its application have been reported conceming metalanalysis,soll analysis,agricultural product analysis,coal analysis,aqueous solution analysis,jewel authenticate and etc.
High energy lamp pumped solid state Q-switched laser at 532nm has the features of high single pulse energy,short pulse
duration,high peak power,and without water cooling machine,which is widely used in LIF, LIBS, ICP-MS, Raman, scientific research,
and so on.

Feature:
CNI self-made high performance laser source
Long-distance, real-time, online,Small size, quick response
Easy to install, uninstall and maintain
Adapt to the harsh environment
Customized solutions available
Accessories:

SPECIFICATIONS:
.
Model |
LPS-532-A |
LPS-532-L |
|
Wavelength (nm) |
532±1 |
||
Operating mode |
Q-switched: EOM (Electro-optic modulation) |
||
Single pulse energy (mJ) |
30,50,80,100 |
200,250,350,450 |
|
Pulse duration (ns) |
<12,<10 |
<10,<8 |
|
Rep. rate (Hz) |
1~10 (adjustable) |
||
Energy stability |
<3%,<5% |
<1%,<3%,<5% |
|
Beam divergence, full angle (mrad) |
~1.5,~1.0 |
~1,~3 |
|
Beam diameter (mm) |
<6/7 |
7/8/9 |
|
Warm-up time (minutes) |
<15 |
||
Beam height from base plate (mm) |
123 |
80 |
|
Cooled method |
Water to Air Cooled |
Water Cooled |
|
Operating temperature (℃) |
20-25 |
15-35 |
|
Power supply (220/110VAC) |
PSU-LPS-A(3U) |
PSU-LPS-L(3U) |
|
Expected lifetime of lamp (pulses) |
10^7-10^8 |
||
Warranty period |
1 year |
||
Available Options |
Jitter:~1ns(Sdev); Accessories |
Higher repetition rates:≤20Hz; Jitter :~1ns(Sdev); Accessories |
|


LPS-532-L Laser Head and Power supply









Send Inquiry to This Supplier
You May Also Like
-
Honeywell SiF4 Gas Detector MIDAS-E-HFX MIDAS-K-HFX Original and NewNegotiableMOQ: 1 Piece
-
LD 200 Halogen Gas Freon CFCs HCFCs HFCS HFO Refrigerant Leak Detector LD-200NegotiableMOQ: 1
-
High Quality Gas Leak DetectorNegotiableMOQ: 1 Piece
-
Dual Digital Breath Alcohol TesterNegotiableMOQ: 2000 Pieces
-
Sulfur Hexafluoride SF6 Recycling Device With Function of SF6 FillingUS$ 2,000 - 50,000MOQ: 1 Set
-
Factory Offer NO Gas Detector OEM Gas DetectorUS$ 400 - 600MOQ: 10 Sets
-
BrACAudit Panther-3 (with Camera, Built-in Printer) Breath Alcohol AnalyzerUS$ 568.00 - 568.00MOQ: 3 Pieces
-
CALIBRE Ethylene Golycol Tester Antifreeze TesterNegotiableMOQ: 1020 Pieces
-
Industria Online Portable Gas TesterUS$ 250 - 300MOQ: 1 Unit
-
Professional Sophisticated Automotive Exhaust Gas Analyzer Supplier's ChoiceUS$ 1,830 - 2,100MOQ: 1 Unit