Key Specifications
Get Latest Price
Material:
Other, Global universal model
Condition:
Other, Global universal model
Task:
Other, Global universal model
Payment & Shipping
Payment Methods:
Port of Shipment:
guizhou
Delivery Detail:
Delivery time depends on order quantity.
Material Other, Global universal model
Condition Other, Global universal model
Task Other, Global universal model
Mathematical Model Other, Global universal model
Signal Other, Global universal model
Customized Non-Customized
Structure Other, Global universal model
Operating Temperature -20℃~+60℃
Relative Humidity 5%-95% (non-condensing)
Storage Temperature -40℃~+85℃

I. Overview


WOODWARD 8928-5311 is a RemoteView remote monitoring software, with its core positioning as a remote visual monitoring and operation & maintenance tool for industrial power equipment control systems. Designed specifically for the remote operation and maintenance scenarios of power equipment such as those in the aerospace field and industrial turbines, this software can seamlessly integrate with Woodward 505D and other series of turbine controllers. It enables remote access, status monitoring, and operation control of equipment controllers through a virtual monitoring interface, providing efficient and convenient technical support for the remote operation and maintenance management, fault diagnosis, and parameter configuration of power equipment.


The 8928-5311 RemoteView software features excellent system compatibility and stable data transmission performance. It can access the control system via remote workstations or mobile devices, breaking geographical restrictions to achieve off-site operation and maintenance. Widely applied in high-end power equipment fields such as aerospace, industrial turbine control, and generator sets, it is particularly suitable for complex scenarios with high requirements for equipment operation and maintenance efficiency, high on-site duty costs, or scattered equipment distribution. It can effectively reduce operation and maintenance costs, improve fault handling efficiency, and ensure the continuous and stable operation of power equipment.


II. Product Features


  • Remote Virtual Monitoring Function: It provides a virtual monitoring interface that can real-timely map the operating status and operation interface of on-site controllers. It supports remote synchronous viewing of core equipment operating parameters (such as rotational speed, load, pressure, etc.), controller working status, and fault alarm information, delivering a visual monitoring experience consistent with local operations.

  • Precise Remote Operation Control: It supports issuing operation commands (including core operations such as parameter adjustment and control mode switching) to on-site controllers via remote workstations or mobile devices. The command transmission boasts low latency and precise execution, ensuring the reliability and safety of remote operation and maintenance activities.


  • Highly Adaptive System Compatibility: Tailor-made for Woodward series controllers, it can seamlessly connect with mainstream turbine controllers such as the 505D. It is compatible with Woodward proprietary communication protocols, ensuring stable and smooth data interaction with on-site control systems without the need for additional adaptation and modification.

  • Secure Access Control Mechanism: Equipped with a password-enabled login function that complies with network security specifications, it achieves precise control over remote access through hierarchical permission management, preventing unauthorized access and misoperations, and safeguarding the operational safety of the control system.


  • Convenient Operation & Maintenance Management Function: Integrating functions such as parameter configuration, data log viewing, setting saving, and setting comparison, it allows operation and maintenance personnel to remotely complete the configuration and optimization of controller parameters, retrieve historical operating data and fault logs for analysis, and provide data support for equipment operation and maintenance decision-making.

  • Stable Data Transmission Capability: Adopting reliable data transmission protocols, it has strong anti-interference ability and can achieve stable data interaction in complex network environments. It avoids operation and maintenance errors caused by data loss or transmission delay, ensuring the continuity of remote monitoring and operations.

  • Collaborative Operation & Maintenance Support: It supports linkage with service tools such as Control Assistant, enabling quick completion of operations like parameter configuration, data log export, and data log analysis, simplifying the operation and maintenance process, and improving the efficiency and professionalism of operation and maintenance work.


8237-2046


III. Technical Parameters


1. Core Basic Parameters

  • Product Model: WOODWARD 8928-5311

  • Product Type: RemoteView Remote Monitoring Software

  • Manufacturer: Woodward

  • Core Functions: Remote virtual monitoring, remote operation control, parameter configuration, data log viewing, permission management, setting saving and comparison

  • Compatible Controllers: Woodward 505D and other series of turbine controllers

  • Application Fields: Aerospace, industrial turbine control, generator sets, high-end power equipment operation and maintenance, etc.

  • Access Methods: Support access via remote workstations and mobile devices


2. Operating Environment Parameters

  • Operating System Compatibility: Support mainstream desktop operating systems such as Windows and mobile device operating systems (refer to the official manual for specific versions)

  • Network Requirements: Support access via standard networks such as Ethernet, with a recommended network bandwidth ≥ 1 Mbps

  • Communication Protocol: Compatible with Woodward proprietary communication protocols

  • Login Mechanism: Password-enabled login, supporting hierarchical permission management

  • Linked Tools: Compatible with service tools such as Control Assistant


3. Functional Performance Parameters

  • Data Update Latency: ≤ 200 ms (typical value, subject to network environment)

  • Log Storage: Support remote retrieval and saving of operating data and fault logs

  • Operation Response Time: ≤ 300 ms (typical value, from command issuance to execution completion)

  • Concurrent Access: Support multi-terminal concurrent monitoring of a single controller (refer to the official manual for the maximum number of concurrent connections)


IV. Working Principle


The core working principle of the WOODWARD 8928-5311 RemoteView remote monitoring software is to achieve real-time linkage between remote terminals and on-site controllers through a closed-loop process of network link establishment - data interaction - command transmission - status feedback. The specific working process can be divided into four core stages:

Stage 1: Secure Link Establishment StageAfter the remote terminal (workstation or mobile device) installs and launches the software, it accesses the on-site control system via the network and completes security authentication by entering authorized account and password. The software performs protocol handshake with controllers such as the Woodward 505D and establishes an encrypted data transmission link to ensure the security and confidentiality of data transmission.


Stage 2: Data Acquisition and Synchronization StageThrough the established transmission link, the software real-timely collects core data such as equipment operating parameters, controller working status, and fault alarm information from on-site controllers. After data parsing and format conversion, the data is synchronously displayed on the remote virtual interface, realizing remote visualization of on-site status.

Stage 3: Remote Operation and Command Transmission StageOperation and maintenance personnel issue operation commands (such as parameter adjustment and mode switching) through the remote virtual interface. The software encapsulates the commands into signals that comply with Woodward communication protocols and transmits them to on-site controllers via the encrypted link. After receiving the commands, the controllers verify their validity and drive the actuators to complete corresponding operations once the commands are confirmed legal.


Stage 4: Execution Result Feedback StageAfter completing the operations, the on-site controllers send the command execution results and updated equipment status data back to the remote software. Upon receiving the data, the software updates the display content of the virtual interface and records operation logs and status change information, forming a complete closed loop of remote operations to facilitate operation and maintenance traceability and subsequent analysis.


V. Common Fault Troubleshooting


1. Failure to Establish Connection with On-site Controllers

Phenomenon: The software cannot search for on-site controllers after startup; a "connection failed" prompt appears when attempting to connect; the connection is frequently disconnected during the connection process.

Causes: Network disconnection or incorrect network configuration between the remote terminal and the on-site control system; incorrect login account or password, or insufficient permissions; controller communication interface failure; incompatibility between the software and controller model; network firewall blocking data transmission ports.

Solutions: 1. Check the network connection status between the remote terminal and the on-site control system, verify network configurations such as IP address and subnet mask to ensure network interconnection. 2. Confirm that the login account and password are correct and have remote connection permissions; contact the system administrator for permission upgrade if permissions are insufficient. 3. Check the working status of the on-site controller communication interface to troubleshoot loose or faulty interface issues. 4. Verify the compatibility between the software and controller model to ensure the use of a software version matching the controller. 5. Check the network firewall settings and open the ports required for software data transmission to avoid port blocking.


2. Remote Data Update Latency/Data Loss

Phenomenon: The data displayed on the remote virtual interface is inconsistent with the actual data of the on-site controller, with obvious latency; some operating parameters or fault information are missing and cannot be displayed completely.

Causes: Insufficient network bandwidth or unstable network signals; strong electromagnetic interference in the network environment; unreasonable setting of software data update frequency; abnormal data transmission cache of the controller.

Solutions: 1. Check the network bandwidth to ensure it meets the software operation requirements; optimize the network environment and increase bandwidth if necessary. 2. Troubleshoot interference sources in the network environment, perform shielding treatment on network lines, or use wired networks instead of wireless networks to improve stability. 3. Enter the software settings interface, adjust data update frequency parameters to balance update speed and network load. 4. Restart the on-site controller and remote terminal to clear the data transmission cache and restore smooth data transmission.


3. Failure to Execute Remote Operation Commands/Abnormal Execution

Phenomenon: Commands such as parameter adjustment and mode switching issued via the software have no response; command execution results are inconsistent with expectations; the controller exhibits abnormal status after execution.

Causes: Insufficient operation permissions, without authorization to issue commands; command parameters exceeding the allowable range of the controller; disconnection of the communication link between the software and the controller; the controller being in local lock mode, prohibiting remote operations; incorrect command format.

Solutions: 1. Confirm that the currently logged-in account has permission to issue commands; apply for permission upgrade if permissions are insufficient. 2. Verify command parameters to ensure parameter values are within the rated allowable range of the controller, avoiding illegal parameter input. 3. Check the communication link status and try issuing commands again after re-establishing the connection. 4. Contact on-site staff to confirm whether the controller is in local lock mode, and perform remote operations after unlocking. 5. Verify the command input format and re-enter commands in accordance with software operation specifications to avoid execution failure caused by format errors.


4. Software Startup Failure/Crash

Phenomenon: The software displays an error message and terminates after startup; no response after startup and crash after a period of time; failure to load the virtual monitoring interface normally.

Causes: Incompatibility between the remote terminal operating system and software version; damaged or missing software installation files; insufficient terminal hardware configuration to meet software operation requirements; missing installation of dependent components required for software operation.

Solutions: 1. Verify the system requirements for software operation to ensure the remote terminal operating system version meets compatibility standards; upgrade the system or replace it with a compatible terminal if not. 2. Uninstall the current software, download the installation file from the official Woodward channel again and complete the installation to repair damaged or missing files. 3. Check the terminal hardware configuration (memory, processor, etc.) to ensure it meets the minimum configuration requirements for software operation; upgrade hardware if insufficient. 4. Install dependent components required for software operation (such as runtime libraries and drivers), and restart the terminal before launching the software again.