Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > 0.6/1kV EPR Insulated Low Smoke Halogen-free Marine Cable LSOH Offshore Power Cable

0.6/1kV EPR Insulated Low Smoke Halogen-free Marine Cable LSOH Offshore Power Cable

0.6/1kV EPR Insulated Low Smoke Halogen-free Marine Cable LSOH Offshore Power Cable photo-1
0.6/1kV EPR Insulated Low Smoke Halogen-free Marine Cable LSOH Offshore Power Cable photo-2
0.6/1kV EPR Insulated Low Smoke Halogen-free Marine Cable LSOH Offshore Power Cable photo-3
0.6/1kV EPR Insulated Low Smoke Halogen-free Marine Cable LSOH Offshore Power Cable photo-4
US$ 0.5 - 10 MOQ: 200 Meters
Key Specifications
Get Latest Price
Brand Name:
Nanyang Cable
Model Number:
CEPF/SC/NC; CEPJ/SC/NC; CEPF86/SC/NC; CEPJ85/SC/NC; CEPFR/SC; CEPJR/SC;
Type:
Low Voltage
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai
Delivery Detail:
15 days
Brand Name Nanyang Cable
Model Number CEPF/SC/NC; CEPJ/SC/NC; CEPF86/SC/NC; CEPJ85/SC/NC; CEPFR/SC; CEPJR/SC;
Type Low Voltage
Application Marine
Insulation Material Other, EPR
Jacket Other, LSZH XLPE/PE
Conductor Material Copper

· Marine LSOH Power Cable

1.Standard:

IEC 60092-350-2014    IEC 60092-353-2016    GB/T 9331-2008

2.Application

Used for the power transmission in ships & on oil platform and other over - water buildings as well as power cables for port machineries. 

3. Operational performance:

1).Rated VoltageU0/U: 0.6/1kV

2). Minimum allowed bending radius for layingD: outer diameter

4D (D25mm)6D (D>25mm)

3). Maximum conductor temperature for continuous operation: ≤90℃

4). Minimum laying temperature-20℃

4. Type & Model:

Type

Model

CEPF/SC/NC

EPR Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable  / SC/NC

CEPJ/SC/NC

EPR Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable  / SC/NC 

CEPF86/SC/NC

EPR Insulated Non-cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC 

CEPJ85/SC/NC

EPR Insulated Cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC 

CEPF96/SC/NC

EPR Insulated Non-cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC 

CEPJ95/SC/NC

EPR Insulated Cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC 

CEPFR/SC

EPR Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Flexible Power Cable/ SC

CEPJR/SC

EPR Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Flexible Power Cable/ SC

CJPF/SC/NC

XLPE Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/SC/NC

CJPJ/SC/NC

XLPE Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/SC/NC 

CJPF86/SC/NC

XLPE Insulated Non-cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC 

CJPJ85/SC/NC

XLPE Insulated Cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC 

CJPF96/SC/NC

XLPE Insulated Non-cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC XLPE 

CJPJ95/SC/NC

XLPE Insulated Cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC XLPE XLPE 

CJPFR/SC

XLPE Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/ SC

CJPJR/SC

XLPE Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/ SC 

5.Fire Resistance:

Type of SC:  Up to standard of Class A Combustion Requirements of Bunched Flame Retardant as per IEC 60332-3 (IEC 60754-1,2;  IEC 61034-1,2;  IEC 60684-2)

Type of NC:  Up to standard of Class A Combustion Requirements of Bunched Flame Retardant as per IEC 60331-21 &

 IEC 60332-3 (IEC 60754-1,2;  IEC 61034-1,2;  IEC 60684-2)

6. Specs. Range

Core No.

Nominal Cross Sectionmm2

1

1-300

2

1-120

3

1-185

4-37

1-2.5

Remarks: Special customizing is available.

Product Tags: Marine Cable , Marine Shipboard Cable , Offshore Power Cables , Cable Manufacturer , Cable Supplier , marine steering cable , Shipboard Electrical Wire , marine cable pass through , marine shift cable

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2003
Factory Size
30,000-50,000 square meters
Annual Export Value
US$2.5 Million - US$5 Million