Module Spare Parts IC693DNM200
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| IC693DNM200 |
5201 STATION NUMBER Sets the slave number for the ACS 140 in Modbus network. Range: 1 - 247 Note! Modifications take effect only on the next power up. 5202 COMM SPEED Defines the communication speed of the ACS 140 in bits per second (bps). Note! Modifications take effect only on the next power-up. 5203 PARITY Defines the parity to be used in Modbus communication. Parameter also defines the number of stop bits. In Modbus communication, the number of stop bits is 2 with no parity bit, and 1 with even or odd parity. 0 = NONE 1 = EVEN 2 = ODD Note! Modifications take effect only on the next power-up. 5204 COMM FAULT TIME Time limit for communication loss detection. This parameter is used together with parameter 5205 COMM FAULT FUNC to define the ACS 140 operation when the communication with the master device in the Modbus network is lost. The master device in the Modbus network must signal its presence to every slave device (ACS 140) in the network by periodically writing Command Word, External Reference 1 or External Reference 2 to each ACS 140 in the network. Maximum write period is set by this parameter. Range: 0.1 - 60.0 s Note! During the first 4 seconds after power-up, communication fault is not evaluated to compensate for possible long system start-up delay. 5205 COMM FAULT FUNC Operation in case the communication with the master device is lost. The time limit for communication loss detection is set by parameter 5204 COMM FAULT TIME. 0 = NOT SEL Communication loss is not detected. 1 = FAULT A fault indication is shown on the control panel display and included in the Status Word. The ACS 140 coasts to stop. 2 = CONST SPEED 7 A warning indication is shown on the control panel display and included in the Status Word. The speed reverts to the level set by parameter 1208 CONST SPEED 7. 3 = REFERENCE A warning indication is shown on the control panel display and included in the Status Word. The speed reverts to the level set by the current frequency reference. Warning! If CONST SPEED 7 or REFERENCE is selected, ensure it is safe to continue operation in case communication with the master device fails. 3 = 300 bps 48 = 4800 bps 6 = 600 bps 96 = 9600 bps 12 = 1200 bps 192 = 19200 bps 24 = 2400 bps 14 Control Locations The ACS 140 drive can receive control information fromn be
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts IC698CRE040-HNUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IC698PSA100US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IC698RMX016 VMIVME-5567-100US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IC754VSF12CTDUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IDP10-AF1C01FUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IS200DTAIH1ABBUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IS200DTAIH1ABB IS210DTAOH1AAUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare PartsIS200DTAIH1ACC IS210DTAOH1AAUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IS200DTAOH1ABA IS210DTAOH1AAUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts IS200EPSMG1ABBUS$ 1 - 100000MOQ: 1 Piece